Cited by 104Diabetes Treatment and ManagementClinical Nutrition and GastroenterologyHyperglycemia and glycemic control in critically ill and hospitalized patients

Effects of exogenous glucagon-like peptide-1 on gastric emptying and glucose absorption in the critically ill: Relationship to glycemia*

Deane, Adam M., Chapman, Marianne J., Fraser, Robert J. L., Summers, Matthew J., Zaknic, Antony V., Storey, James P., Jones, Karen L., Rayner, Christopher K. +1 more·2010·Critical Care Medicine

Abstract

OBJECTIVE: To determine the acute effects of exogenous glucagon-like peptide-1 on gastric emptying, glucose absorption, glycemia, plasma insulin, and glucagon in critically ill patients. DESIGN: Randomized, double-blind, crossover study. SETTING: Intensive care unit. SUBJECTS: Twenty-five mechanically ventilated patients, without known diabetes, studied on consecutive days. INTERVENTIONS: Intravenous glucagon-like peptide-1 (1.2 pmol/kg/min) or placebo was infused between -30 and 330 mins. At 0 min, 100 mL liquid nutrient (1 kcal/mL) including 100 microg of 13C-octanoic acid and 3 grams of 3-O-methyl-glucose was administered. MEASUREMENTS AND MAIN RESULTS: Blood glucose, serum 3-O-methyl-glucose (as an index of glucose absorption), insulin and glucagon concentrations, as well as exhaled 13CO2 were measured. The gastric emptying coefficient was calculated to quantify gastric emptying. Data are presented as mean (sd). There was a nonsignificant trend for glucagon-like peptide-1 to slow gastric emptying (gastric emptying coefficient) (glucagon-like peptide-1, 2.45 [0.93] vs. placebo, 2.75 [0.83]; p = .09). In 11 of the 25 patients, gastric emptying was delayed during placebo infusion and glucagon-like peptide-1 had no detectable effect on gastric emptying in this group (1.92 [0.82] vs. 1.90 [0.68]; p = .96). In contrast, in patients who had normal gastric emptying during placebo, glucagon-like peptide-1 slowed gastric emptying substantially (2.86 [0.58] vs. 3.41 [0.37]; p = .006). Glucagon-like peptide-1 markedly reduced the rate of glucose absorption (3-O-methyl-glucose area under the curve(0-330), 37 [35] vs. 76 [51] mmol/L/min; p < .001), decreased preprandial glucagon (at 0 min change in glucagon, -15 [15] vs. -3 [14] pmol/L; p < .001), increased the insulin/glucose ratio throughout the infusion (area under the curve(-30-330), 1374 [814] vs. 1172 [649] mU/mmol/min; p = .041), and attenuated the glycemic response to the meal (glucose area under the curve(0-330), 2071 [353] vs. 2419 [594] mmol/L/min; p = .001). CONCLUSIONS: Exogenous glucagon-like peptide-1 lowers postprandial glycemia in the critically ill. This may occur, at least in part, by slowing gastric emptying when the latter is normal but not when it is delayed.

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181d9d87a

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • GLP-1RAs have been shown to reduce intestinal uptake of glucose and lipids.

    “In one study, osmotic diarrhea occurred 8 h after infusion of GLP-1 peptide (47), and GLP-1RAs have been shown to reduce intestinal uptake of glucose and lipids (48, 49).”

    From Safety of Semaglutide (2021) · cites this paper as [48]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Deane, A. M., Chapman, M. J., Fraser, R. J. L., Summers, M. J., Zaknic, A. V., Storey, J. P., Jones, K. L., Rayner, C. K., & Horowitz, M.
Affiliations
Royal Adelaide Hospital (AU)
Venue
Critical Care Medicine
Published
2010-05
Volume
38
Issue
5
Pages
1261-1269
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2007994658
Cited by
104
References
13
Citations by year
2026: 2 · 2025: 4 · 2024: 8 · 2023: 2 · 2022: 4 · 2021: 6 · 2020: 5 · 2019: 6 · 2018: 4 · 2017: 4 · 2016: 7 · 2015: 12 · 2014: 11 · 2013: 11 · 2012: 7
FWCI
6.77
Type
journal article
Language
en
Open access
closed
Locations
  • Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
  • Health Sciences › Nursing › Nutrition and Dietetics › Clinical Nutrition and Gastroenterology
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
Keywords
glucagon-like peptide-1, gastric emptying, glucose absorption, critically ill patients, intensive care unit, mechanical ventilation, glycemia, insulin, glucagon, 3-O-methylglucose, enteral nutrition, hyperglycemia, insulin resistance, glucagon resistance, glucagon secretion
MeSH terms
Blood Glucose, Breath Tests, Double-Blind Method, Gastric Emptying, Glucagon, Glucose, Humans, Insulin, Intensive Care Units, Respiration, Artificial, Critical Illness, Cross-Over Studies, 3-O-Methylglucose, Glucagon-Like Peptide 1

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review