Comparison of four different vascular occlusion tests for assessing reactive hyperemia using near-infrared spectroscopy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare data gathered via four different types of vascular occlusion test (VOT) by using near-infrared spectroscopy. The data may support a standardized method to appropriately measure the postischemic recovery slope, which is currently emphasized as a quantitative marker of the microvascular reserve in septic patients. DESIGN: Prospective study. SETTING: Medical intensive care unit of a university hospital. PATIENTS AND MEASUREMENTS: In 20 healthy volunteers and in 20 septic shock patients, we measured muscle tissue oxygen saturation at the thenar eminence by using near-infrared spectroscopy and performed four different vascular occlusion tests in a random order. A pneumatic cuff was placed around either the upper arm (A) or the forearm (FA). Cuff inflation was maintained either during 3 mins (VOT(A3min) and VOT(FA3min)) or until muscle tissue oxygen saturation decreased to 40% (VOT(A40%) and VOT(FA40%)). RESULTS: In volunteers: 1) During VOT(A3min) and VOT(FA3min), the minimal muscle tissue oxygen saturation was significantly higher than 40% (52% ± 10% and 54% ± 6%, respectively), and 2) the muscle tissue oxygen saturation recovery slopes were steeper with VOT(A40%) and VOT(FA40%) than with VOT(A3min) and VOT(FA3min), respectively. Considering the pooled data obtained during VOT(A3min) and VOT(FA3min) (n = 40), recovery slope negatively correlated with minimal muscle tissue oxygen saturation in volunteers (r² = .46, p < .0001) as in septic patients (r² = .34, p = .0001). Considering the pooled data obtained during 40% VOTs, the recovery slope did not correlate with ischemic time in either group. The overlap of recovery slopes between volunteers and septic patients was small for both 40% VOTs but large for both 3-min occlusion VOTs. CONCLUSION: The comparison of recovery slopes between volunteers and septic patients and the fact that the recovery slope was influenced by the extent of muscle tissue oxygen saturation decrease during ischemia and not by the ischemic time both support the use of a fixed minimal muscle tissue oxygen saturation target (40%) over the use of a fixed ischemic time (3 mins) for assessing reactive hyperemia by using near-infrared spectroscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bezemer, R., Lima, A., Myers, D., Klijn, E., Heger, M., Goedhart, P. T., Bakker, J., & Ince, C. (2009) · Critical Care · doi:10.1186/cc8002 · Cited by 103 · cited 1×
“were found to differ depending on probe spacing, probe placement, and the predefined StO2 target (8, 9).”
BackgroundGómez, H., Mesquida, J., Simon, P., Kim, H. K., Puyana, J. C., Ince, C., & Pinsky, M. R. (2009) · Critical Care · doi:10.1186/cc8001 · Cited by 94 · cited 5×
“were found to differ depending on probe spacing, probe placement, and the predefined StO2 target (8, 9).”
BackgroundMethodResultInfluential
Cited by
Reactive hyperemia: a review of methods, mechanisms, and considerations
Rosenberry, R., & Nelson, M. D. (2020) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00339.2019 · Cited by 242
Petroni, T., Harrois, A., Amour, J., Lebreton, G., Brechot, N., Tanaka, S., Luyt, C.-E., Trouillet, J.-L., Chastre, J., Leprince, P., et al. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000410 · Cited by 176
Keller, J. L., Traylor, M. K., Gray, S. M., Hill, E. C., & Weir, J. P. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00174.2023 · Cited by 44
Fellahi, J.-L., Butin, G., Fischer, M.-O., Zamparini, G., Gérard, J.-L., & Hanouz, J.-L. (2013) · Journal of Critical Care · doi:10.1016/j.jcrc.2013.05.004 · Cited by 42
Lee, J.-H., Park, Y.-H., Kim, H.-S., & Kim, J.-T. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9595-1 · Cited by 20
Metadata
- Authors
- Mayeur, C., Campard, S., Richard, C., & Teboul, J.-L.
- Venue
- Critical Care Medicine
- Published
- 2011-04
- Volume
- 39
- Issue
- 4
- Pages
- 695-701
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2029158148
- Cited by
- 91
- References
- 2
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of four different vascular occlusion tests for assessing reactive hyperemia using near-infrared spectroscopy. https://app.cochat.ai/papers/10.1097/ccm.0b013e318206d256
- The paper
- Mayeur, C., Campard, S., Richard, C., & Teboul, J.-L. (2011). Comparison of four different vascular occlusion tests for assessing reactive hyperemia using near-infrared spectroscopy. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e318206d256
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.