Cited by 311Nosocomial Infections in ICURespiratory Support and MechanismsAirway Management and Intubation Techniques

Subglottic secretion drainage for the prevention of ventilator-associated pneumonia: a systematic review and meta-analysis

Muscedere, John, Rewa, Oleksa, Mckechnie, Kyle, Jiang, Xuran, Laporta, Denny, Heyland, Daren K.·2011·Critical Care Medicine

Abstract

BACKGROUND AND PURPOSE: Aspiration of secretions containing bacterial pathogens into the lower respiratory tract is the main cause of ventilator-associated pneumonia. Endotracheal tubes with subglottic secretion drainage can potentially reduce this and, therefore, the incidence of ventilator-associated pneumonia. New evidence on subglottic secretion drainage as a preventive measure for ventilator-associated pneumonia has been recently published and to consider the evidence in totality, we conducted an updated systematic review and meta-analysis. DESIGN: We searched computerized databases, reference lists, and personal files. We included randomized clinical trials of mechanically ventilated patients comparing standard endotracheal tubes to those with subglottic secretion drainage and reporting on the occurrence of ventilator-associated pneumonia. Studies were meta-analyzed for the primary outcome of ventilator-associated pneumonia and secondary clinical outcomes. MEASUREMENTS AND MAIN RESULTS: We identified 13 randomized clinical trials that met the inclusion criteria with a total of 2442 randomized patients. Of the 13 studies, 12 reported a reduction in ventilator-associated pneumonia rates in the subglottic secretion drainage arm; in meta-analysis, the overall risk ratio for ventilator-associated pneumonia was 0.55 (95% confidence interval, 0.46-0.66; p < .00001) with no heterogeneity (I = 0%). The use of subglottic secretion drainage was associated with reduced intensive care unit length of stay (-1.52 days; 95% confidence interval, -2.94 to -0.11; p = .03); decreased duration of mechanically ventilated (-1.08 days; 95% confidence interval, -2.04 to -0.12; p = .03), and increased time to first episode of ventilator-associated pneumonia (2.66 days; 95% confidence interval, 1.06-4.26; p = .001). There was no effect on adverse events or on hospital or intensive care unit mortality. CONCLUSIONS: In those at risk for ventilator-associated pneumonia, the use of endotracheal tubes with subglottic secretion drainage is effective for the prevention of ventilator-associated pneumonia and may be associated with reduced duration of mechanical ventilation and intensive care unit length of stay.

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318218a4d9

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The predicted effect of ecological forces in the lungs of critically ill patients is a state of increased immigration, decreased elimination, and favourable growth conditions for potential pathogens.

    “The predicted effect of these ecological forces in the lungs, therefore, is a state of increased immigration, decreased elimination, and favourable growth conditions for potential pathogens.”

    From The microbiome and critical illness (2016) · cites this paper as [61]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Muscedere, J., Rewa, O., Mckechnie, K., Jiang, X., Laporta, D., & Heyland, D. K.
Affiliations
Queen's University (CA)
Venue
Critical Care Medicine
Published
2011-08
Volume
39
Issue
8
Pages
1985-1991
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2013628062
Cited by
311
References
44
Citations by year
2026: 6 · 2025: 8 · 2024: 6 · 2023: 10 · 2022: 12 · 2021: 20 · 2020: 13 · 2019: 18 · 2018: 29 · 2017: 27 · 2016: 25 · 2015: 40 · 2014: 41 · 2013: 31 · 2012: 18
FWCI
4.60
Type
journal article
Language
en
Open access
closed
Locations
  • Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Nosocomial Infections in ICU
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Airway Management and Intubation Techniques
Keywords
subglottic secretion drainage, ventilator-associated pneumonia, endotracheal tube, mechanical ventilation, pneumonia prevention, ICU length of stay, mechanical ventilation duration, critically ill patients
MeSH terms
Critical Care, Female, Follow-Up Studies, Glottis, Humans, Intensive Care Units, Intubation, Intratracheal, Male, Respiration, Artificial, Suction, Survival Rate, Randomized Controlled Trials as Topic, Critical Illness, Treatment Outcome, Hospital Mortality, Risk Assessment, Pneumonia, Ventilator-Associated

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review