The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
The risk of catheter-related bloodstream infection with femoral venous catheters as compared to subclavian and internal jugular venous catheters: A systematic review of the literature and meta-analysis*
Abstract
BACKGROUND: Catheter-related bloodstream infections are an important cause of morbidity and mortality in hospitalized patients. Current guidelines recommend that femoral venous access should be avoided to reduce this complication (1A recommendation). However, the risk of catheter-related bloodstream infections from femoral as compared to subclavian and internal jugular venous catheterization has not been systematically reviewed. OBJECTIVE: A systematic review of the literature to determine the risk of catheter-related bloodstream infections related to nontunneled central venous catheters inserted at the femoral site as compared to subclavian and internal jugular placement. DATA SOURCES: MEDLINE, Embase, Cochrane Register of Controlled Trials, citation review of relevant primary and review articles, and an Internet search (Google). STUDY SELECTION: Randomized controlled trials and cohort studies that reported the frequency of catheter-related bloodstream infections (infections per 1,000 catheter days) in patients with nontunneled central venous catheters placed in the femoral site as compared to subclavian or internal jugular placement. DATA EXTRACTION: Data were abstracted on study design, study size, study setting, patient population, number of catheters at each insertion site, number of catheter-related bloodstream infections, and the prevalence of deep venous thrombosis. Studies were subgrouped according to study design (cohort and randomized controlled trials). Meta-analytic techniques were used to summarize the data. DATA SYNTHESIS: Two randomized controlled trials (1006 catheters) and 8 cohort (16,370 catheters) studies met the inclusion criteria for this systematic review. Three thousand two hundred thirty catheters were placed in the subclavian vein, 10,958 in the internal jugular and 3,188 in the femoral vein for a total of 113,652 catheter days. The average catheter-related bloodstream infections density was 2.5 per 1,000 catheter days (range 0.6-7.2). There was no significant difference in the risk of catheter-related bloodstream infections between the femoral and subclavian/internal jugular sites in the two randomized controlled trials (i.e., no level 1A evidence). There was no significant difference in the risk of catheter-related bloodstream infections between the femoral and subclavian sites. The internal jugular site was associated with a significantly lower risk of catheter-related bloodstream infections compared to the femoral site (risk ratio 1.90; 95% confidence interval 1.21-2.97, p=.005, I²=35%). This difference was explained by two of the studies that were statistical outliers. When these two studies were removed from the analysis there was no significant difference in the risk of catheter-related bloodstream infections between the femoral and internal jugular sites (risk ratio 1.35; 95% confidence interval 0.84-2.19, p=0.2, I=0%). Meta-regression demonstrated a significant interaction between the risk of infection and the year of publication (p=.01), with the femoral site demonstrating a higher risk of infection in the earlier studies. There was no significant difference in the risk of catheter-related bloodstream infection between the subclavian and internal jugular sites. The risk of deep venous thrombosis was assessed in the two randomized controlled trials. A meta-analysis of this data demonstrates that there was no difference in the risk of deep venous thrombosis when the femoral site was compared to the subclavian and internal jugular sites combined. There was, however, significant heterogeneity between studies. CONCLUSIONS: Although earlier studies showed a lower risk of catheter-related bloodstream infections when the internal jugular was compared to the femoral site, recent studies show no difference in the rate of catheter-related bloodstream infections between the three sites.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
The combination of estimates from different experiments
Cochran, W. G. (1954) · Biometrics · doi:10.2307/3001666 · Cited by 5,380
Moher, D., Cook, D. J., Eastwood, S., Olkin, I., Rennie, D., & Stroup, D. F. (1999) · The Lancet · doi:10.1016/s0140-6736(99)04149-5 · Cited by 4,826
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
meta-analysis bias in location and selection of studies
Egger, M., & Smith, G. D. (1998) · BMJ · doi:10.1136/bmj.316.7124.61 · Cited by 1,374
Edwards, J. R., Peterson, K. D., Mu, Y., Banerjee, S., Allen-Bridson, K., Morrell, G., Dudeck, M. A., Pollock, D. A., & Horan, T. C. (2009) · American Journal of Infection Control · doi:10.1016/j.ajic.2009.10.001 · Cited by 1,258
Merrer, J. (2001) · JAMA · doi:10.1001/jama.286.6.700 · Cited by 1,187
Systematic Review: Why sources of heterogeneity in meta-analysis should be investigated
Thompson, S. G. (1994) · BMJ · doi:10.1136/bmj.309.6965.1351 · Cited by 1,017
Cited by
KDOQI Clinical Practice Guideline for Vascular Access: 2019 Update
Lok, C. E., Huber, T. S., Lee, T., Shenoy, S., Yevzlin, A. S., Abreo, K., Allon, M., Asif, A., Astor, B. C., Glickman, M. H., et al. (2020) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2019.12.001 · Cited by 2,590
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Management of post-hepatectomy complications
Jin, S. (2013) · World Journal of Gastroenterology · doi:10.3748/wjg.v19.i44.7983 · Cited by 260
Renal replacement therapy in adult and pediatric intensive care
Vinsonneau, C., Allain-Launay, E., Blayau, C., Darmon, M., du Cheyron, D., Gaillot, T., Honore, P. M., Javouhey, E., Krummel, T., Lahoche, A., et al. (2015) · Annals of Intensive Care · doi:10.1186/s13613-015-0093-5 · Cited by 151
Metadata
- Authors
- Marik, P. E., Flemmer, M., & Harrison, W.
- Venue
- Critical Care Medicine
- Published
- 2012-08
- Volume
- 40
- Issue
- 8
- Pages
- 2479-2485
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2102347070
- Cited by
- 272
- References
- 33
- FWCI
- 39.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The risk of catheter-related bloodstream infection with femoral venous catheters as compared to subclavian and internal jugular venous catheters: A systematic review of the literature and meta-analysis*. https://app.cochat.ai/papers/10.1097/ccm.0b013e318255d9bc
- The paper
- Marik, P. E., Flemmer, M., & Harrison, W. (2012). The risk of catheter-related bloodstream infection with femoral venous catheters as compared to subclavian and internal jugular venous catheters: A systematic review of the literature and meta-analysis*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e318255d9bc
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.