Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 272

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

The risk of catheter-related bloodstream infection with femoral venous catheters as compared to subclavian and internal jugular venous catheters: A systematic review of the literature and meta-analysis*

Marik, Paul E., Flemmer, Mark, Harrison, Wendy·2012·Critical Care Medicine

Abstract

BACKGROUND: Catheter-related bloodstream infections are an important cause of morbidity and mortality in hospitalized patients. Current guidelines recommend that femoral venous access should be avoided to reduce this complication (1A recommendation). However, the risk of catheter-related bloodstream infections from femoral as compared to subclavian and internal jugular venous catheterization has not been systematically reviewed. OBJECTIVE: A systematic review of the literature to determine the risk of catheter-related bloodstream infections related to nontunneled central venous catheters inserted at the femoral site as compared to subclavian and internal jugular placement. DATA SOURCES: MEDLINE, Embase, Cochrane Register of Controlled Trials, citation review of relevant primary and review articles, and an Internet search (Google). STUDY SELECTION: Randomized controlled trials and cohort studies that reported the frequency of catheter-related bloodstream infections (infections per 1,000 catheter days) in patients with nontunneled central venous catheters placed in the femoral site as compared to subclavian or internal jugular placement. DATA EXTRACTION: Data were abstracted on study design, study size, study setting, patient population, number of catheters at each insertion site, number of catheter-related bloodstream infections, and the prevalence of deep venous thrombosis. Studies were subgrouped according to study design (cohort and randomized controlled trials). Meta-analytic techniques were used to summarize the data. DATA SYNTHESIS: Two randomized controlled trials (1006 catheters) and 8 cohort (16,370 catheters) studies met the inclusion criteria for this systematic review. Three thousand two hundred thirty catheters were placed in the subclavian vein, 10,958 in the internal jugular and 3,188 in the femoral vein for a total of 113,652 catheter days. The average catheter-related bloodstream infections density was 2.5 per 1,000 catheter days (range 0.6-7.2). There was no significant difference in the risk of catheter-related bloodstream infections between the femoral and subclavian/internal jugular sites in the two randomized controlled trials (i.e., no level 1A evidence). There was no significant difference in the risk of catheter-related bloodstream infections between the femoral and subclavian sites. The internal jugular site was associated with a significantly lower risk of catheter-related bloodstream infections compared to the femoral site (risk ratio 1.90; 95% confidence interval 1.21-2.97, p=.005, I²=35%). This difference was explained by two of the studies that were statistical outliers. When these two studies were removed from the analysis there was no significant difference in the risk of catheter-related bloodstream infections between the femoral and internal jugular sites (risk ratio 1.35; 95% confidence interval 0.84-2.19, p=0.2, I=0%). Meta-regression demonstrated a significant interaction between the risk of infection and the year of publication (p=.01), with the femoral site demonstrating a higher risk of infection in the earlier studies. There was no significant difference in the risk of catheter-related bloodstream infection between the subclavian and internal jugular sites. The risk of deep venous thrombosis was assessed in the two randomized controlled trials. A meta-analysis of this data demonstrates that there was no difference in the risk of deep venous thrombosis when the femoral site was compared to the subclavian and internal jugular sites combined. There was, however, significant heterogeneity between studies. CONCLUSIONS: Although earlier studies showed a lower risk of catheter-related bloodstream infections when the internal jugular was compared to the femoral site, recent studies show no difference in the rate of catheter-related bloodstream infections between the three sites.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318255d9bc

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Cited by

See all 272

Metadata

Authors
Marik, P. E., Flemmer, M., & Harrison, W.
Venue
Critical Care Medicine
Published
2012-08
Volume
40
Issue
8
Pages
2479-2485
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2102347070
Cited by
272
References
33
FWCI
39.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The risk of catheter-related bloodstream infection with femoral venous catheters as compared to subclavian and internal jugular venous catheters: A systematic review of the literature and meta-analysis*. https://app.cochat.ai/papers/10.1097/ccm.0b013e318255d9bc
The paper
Marik, P. E., Flemmer, M., & Harrison, W. (2012). The risk of catheter-related bloodstream infection with femoral venous catheters as compared to subclavian and internal jugular venous catheters: A systematic review of the literature and meta-analysis*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e318255d9bc

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.