Abstract
OBJECTIVE: We studied the variable effects of norepinephrine infusion on cardiac output in postoperative cardiac surgical patients in whom norepinephrine increased mean arterial pressure. We hypothesized that the directional change in cardiac output would be determined by baseline cardiac function, as quantified by stroke volume variation, and the subsequent changes in mean systemic filling pressure and vasomotor tone. DESIGN: Intervention study. SETTING: ICU of a university hospital. PATIENTS: Sixteen mechanically ventilated postoperative cardiac surgery patients. INTERVENTIONS: Inspiratory holds were performed at baseline-1, during increased norepinephrine infusion, and baseline-2 conditions. MEASUREMENTS AND MAIN RESULTS: We measured mean arterial pressure, heart rate, central venous pressure, cardiac output, stroke volume variation and, with use of inspiratory hold maneuvers, mean systemic filling pressure, then calculated resistance for venous return and systemic vascular resistance. Increasing norepinephrine by 0.04 ± 0.02 μg·kg·min increased mean arterial pressure 20 mm Hg in all patients. Cardiac output decreased in ten and increased in six patients. In all patients mean systemic filling pressure, systemic vascular resistance and resistance for venous return increased and stroke volume variation decreased. Resistance for venous return and systemic vascular resistance increased more (p = 0.019 and p = 0.002) in the patients with a cardiac output decrease. Heart rate decreased in the patients with a cardiac output decrease (p = 0.002) and was unchanged in the patients with a cardiac output increase. Baseline stroke volume variation was higher in those in whom cardiac output increased (14.4 ± 4.2% vs. 9.1 ± 2.4%, p = 0.012). Stroke volume variation >8.7% predicted the increase in cardiac output to norepinephrine (area under the receiver operating characteristic curve 0.900). CONCLUSIONS: The change in cardiac output induced by norepinephrine is determined by the balance of volume recruitment (increase in mean systemic filling pressure), change in resistance for venous return, and baseline heart function. Furthermore, the response of cardiac output on norepinephrine can be predicted by baseline stroke volume variation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Dopamine and Norepinephrine in the Treatment of Shock
De Backer, D., Biston, P., Devriendt, J., Madl, C., Chochrad, D., Aldecoa, C., Brasseur, A., Defrance, P., Gottignies, P., & Vincent, J.-L. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0907118 · Cited by 1,940 · cited 1×
“org 143 Norepinephrine (NE) is the vasopressor of choice in septic shock (1) because of its ability to maintain vasomotor tone, but it is also recommended as treatment for resistant cardiogenic shock (2, 3).”
Background
Cited by
Cardiac Output and Cerebral Blood Flow: The Integrated Regulation of Brain Perfusion in Adult Humans
Meng, L., Hou, W., Chui, J., Han, R., & Gelb, A. W. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000872 · Cited by 299
Aya, H. D., Rhodes, A., Chis Ster, I., Fletcher, N., Grounds, R. M., & Cecconi, M. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002067 · Cited by 121
Metadata
- Authors
- Maas, J. J., Pinsky, M. R., de Wilde, R. B., de Jonge, E., & Jansen, J. R.
- Venue
- Critical Care Medicine
- Published
- 2013-01
- Volume
- 41
- Issue
- 1
- Pages
- 143-150
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2052293276
- Cited by
- 163
- References
- 1
- FWCI
- 10.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.