The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Impact of Ventilator Adjustment and Sedation–Analgesia Practices on Severe Asynchrony in Patients Ventilated in Assist-Control Mode*
Abstract
OBJECTIVES: Breath-stacking asynchrony during assist-control-mode ventilation may be associated with increased tidal volume and alveolar pressure that could contribute to ventilator-induced lung injury. Methods to reduce breath stacking have not been well studied. The objective of this investigation was to evaluate 1) which interventions were used by managing clinicians to address severe breath stacking; and 2) how effective these measures were. SETTING: Sixteen-bed medical ICU. PATIENTS AND INTERVENTIONS: Physiological study in consecutively admitted patients without severe brain injury, who had severe breath stacking defined as an asynchrony index greater than or equal to 10% of total breaths. During 30 minutes before (baseline) and after any intervention employed by the managing clinician, the ventilator flow, airway pressure, and volume/time waveforms were continuously recorded and analyzed to detect normal and stacked breaths. The initial approach taken was assigned to one of three categories: no intervention, increase of sedation-analgesia, or change of ventilator setting. Nonparametric Wilcoxon-Mann-Whitney tests and multiple regression were used for statistical analysis. Quantitative data are presented as median [25-75]. MAIN RESULTS: Sixty-six of 254 (26%) mechanically ventilated patients exhibited severe breath-stacking asynchrony. A total of 100 30-minute sequences were recorded and analyzed in 30 patients before and after 50 clinical decisions for ongoing management (no intervention, n=8; increasing sedation/analgesia, n=16; ventilator adjustment, n=26). Breath-stacking asynchrony index was 44 [27-87]% at baseline. Compared with baseline, the decrease of asynchrony index was greater after changing the ventilator setting (-99 [-92, -100]%) than after increasing the sedation-analgesia (-41 [-66, 7]%, p<0.001) or deciding to tolerate the asynchrony (4 [-4, 12]%, p<0.001). Pressure-support ventilation and increased inspiratory time were independently associated with the reduction of asynchrony index. CONCLUSIONS: Compared with increasing sedation-analgesia, adapting the ventilator to patient breathing effort reduces breath-stacking asynchrony significantly and often dramatically. These results support an algorithm beginning with ventilator adjustment to rationalize the management of severe breath-stacking asynchrony in ICU patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sessler, C. N., Gosnell, M. S., Grap, M. J., Brophy, G. M., O'Neal, P. V., Keane, K. A., Tesoro, E. P., & Elswick, R. K. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2107138 · Cited by 3,695
Schweickert, W. D., Pohlman, M. C., Pohlman, A. S., Nigos, C., Pawlik, A. J., Esbrook, C. L., Spears, L., Miller, M., Franczyk, M., Deprizio, D., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60658-9 · Cited by 3,339
Self-citationImpact of systematic evaluation of pain and agitation in an intensive care unit*
Chanques, G., Jaber, S., Barbotte, E., Violet, S., Sebbane, M., Perrigault, P.-F., Mann, C., Lefrant, J.-Y., & Eledjam, J.-J. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000218416.62457.56 · Cited by 536
Self-citation
Cited by
Writing Group for the Alveolar Recruitment for Acute Respiratory Distress Syndrome Trial (ART) Investigators, Cavalcanti, A. B., Suzumura, É. A., Laranjeira, L. N., Paisani, D. D. M., Damiani, L. P., Guimarães, H. P., Romano, E. R., Regenga, M. D. M., Taniguchi, L. N. T., et al. (2017) · JAMA · doi:10.1001/jama.2017.14171 · Cited by 1,018
Asynchronies during mechanical ventilation are associated with mortality
Blanch, L., Villagra, A., Sales, B., Montanya, J., Lucangelo, U., Luján, M., García-Esquirol, O., Chacón, E., Estruga, A., Oliva, J. C., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3692-6 · Cited by 539
Ventilator-induced Lung Injury
Beitler, J. R., Malhotra, A., & Thompson, B. T. (2016) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2016.07.004 · Cited by 347
Yoshida, T., Fujino, Y., Amato, M. B. P., & Kavanagh, B. P. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0748cp · Cited by 346
Analgesia and sedation in patients with ARDS
Chanques, G., Constantin, J.-M., Devlin, J. W., Ely, E. W., Fraser, G. L., Gélinas, C., Girard, T. D., Guérin, C., Jabaudon, M., Jaber, S., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06307-9 · Cited by 313
Self-citation
Metadata
- Authors
- Chanques, G., Kress, J. P., Pohlman, A., Patel, S., Poston, J., Jaber, S., & Hall, J. B.
- Venue
- Critical Care Medicine
- Published
- 2013-09
- Volume
- 41
- Issue
- 9
- Pages
- 2177-2187
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2017608370
- Cited by
- 183
- References
- 3
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impact of Ventilator Adjustment and Sedation–Analgesia Practices on Severe Asynchrony in Patients Ventilated in Assist-Control Mode*. https://app.cochat.ai/papers/10.1097/ccm.0b013e31828c2d7a
- The paper
- Chanques, G., Kress, J. P., Pohlman, A., Patel, S., Poston, J., Jaber, S., & Hall, J. B. (2013). Impact of Ventilator Adjustment and Sedation–Analgesia Practices on Severe Asynchrony in Patients Ventilated in Assist-Control Mode*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e31828c2d7a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.