Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 313

The DOI matches its Crossref record; 133 of the 133 references it cites were found in a registry or an index.

European Society of Anaesthesiology and European Board of Anaesthesiology guidelines for procedural sedation and analgesia in adults

Open access
Hinkelbein, Jochen, Lamperti, Massimo, Akeson, Jonas, Santos, Joao, Costa, Joao, De Robertis, Edoardo, Longrois, Dan, Novak-Jankovic, Vesna, Petrini, Flavia, Struys, Michel M.R.F., Veyckemans, Francis, Fuchs-Buder, Thomas, Fitzgerald, Robert·2018·European Journal of Anaesthesiology

Abstract

: Procedural sedation and analgesia (PSA) has become a widespread practice given the increasing demand to relieve anxiety, discomfort and pain during invasive diagnostic and therapeutic procedures. The role of, and credentialing required by, anaesthesiologists and practitioners performing PSA has been debated for years in different guidelines. For this reason, the European Society of Anaesthesiology (ESA) and the European Board of Anaesthesiology have created a taskforce of experts that has been assigned to create an evidence-based guideline and, whenever the evidence was weak, a consensus amongst experts on: the evaluation of adult patients undergoing PSA, the role and competences required for the clinicians to safely perform PSA, the commonly used drugs for PSA, the adverse events that PSA can lead to, the minimum monitoring requirements and post-procedure discharge criteria. A search of the literature from 2003 to 2016 was performed by a professional librarian and the retrieved articles were analysed to allow a critical appraisal according to the Grading of Recommendations Assessment, Development and Evaluation method. The Taskforce selected 2248 articles. Where there was insufficiently clear and concordant evidence on a topic, the Rand Appropriateness Method with three rounds of Delphi voting was used to obtain the highest level of consensus among the taskforce experts.These guidelines contain recommendations on PSA in the adult population. It does not address sedation performed in the ICU or in children and it does not aim to provide a legal statement on how PSA should be performed and by whom. The National Societies of Anaesthesiology and Ministries of Health should use this evidence-based document to help decision-making on how PSA should be performed in their countries. The final draft of the document was available to ESA members via the website for 4 weeks with the facility for them to upload their comments. Comments and suggestions of individual members and national Societies were considered and the guidelines were amended accordingly. The ESA guidelines Committee and ESA board finally approved and ratified it before publication.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/eja.0000000000000683

Cites

133 of 133 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 133 references

Cited by

See all 313

Metadata

Authors
Hinkelbein, J., Lamperti, M., Akeson, J., Santos, J., Costa, J., De Robertis, E., Longrois, D., Novak-Jankovic, V., Petrini, F., Struys, M. M. R. F., Veyckemans, F., Fuchs-Buder, T., & Fitzgerald, R.
Venue
European Journal of Anaesthesiology
Published
2018-01
Volume
35
Issue
1
Pages
6-24
ISSN
0265-0215 (ISSN-L)
OpenAlex
W2750859350
Cited by
313
References
133
FWCI
29.78
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: European Society of Anaesthesiology and European Board of Anaesthesiology guidelines for procedural sedation and analgesia in adults. https://app.cochat.ai/papers/10.1097/eja.0000000000000683
The paper
Hinkelbein, J., Lamperti, M., Akeson, J., Santos, J., Costa, J., De Robertis, E., Longrois, D., Novak-Jankovic, V., Petrini, F., Struys, M. M. R. F., Veyckemans, F., Fuchs-Buder, T., & Fitzgerald, R. (2018). European Society of Anaesthesiology and European Board of Anaesthesiology guidelines for procedural sedation and analgesia in adults. European Journal of Anaesthesiology. https://doi.org/10.1097/eja.0000000000000683

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.