Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record.

Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope

Serocki, Götz, Bein, Berthold, Scholz, Jens, Dörges, Volker · 2010 · European Journal of Anaesthesiology

Abstract

BACKGROUND AND OBJECTIVE: We investigated whether the use of two different video laryngoscopes [direct-coupled interface (DCI) video laryngoscope and GlideScope] may improve laryngoscopic view and intubation success compared with the conventional direct Macintosh laryngoscope (direct laryngoscopy) in patients with a predicted difficult airway. METHODS: One hundred and twenty adult patients undergoing elective minor surgery requiring general anaesthesia and endotracheal intubation presenting with at least one predictor for a difficult airway were enrolled after Institutional Review Board approval and written informed consent was obtained. Repeated laryngoscopy was performed using direct laryngoscope, DCI laryngoscope and GlideScope in a randomized sequence before patients were intubated. RESULTS: Both video laryngoscopes showed significantly better laryngoscopic view (according to Cormack and Lehane classification as modified by Yentis and Lee = C&L) than direct laryngoscope. Laryngoscopic view C&L >or= III was measured in 30% of patients when using direct laryngoscopy, and in only 11% when using the DCI laryngoscope (P < 0.001). The GlideScope enabled significantly better laryngoscopic view (C&L >or= III: 1.6%) than both direct (P < 0.001) and DCI laryngoscopes (P < 0.05). Clinically relevant improvement in the specific 36 patients with insufficient direct view (C&L >or= III) could be achieved significantly more often with the GlideScope (94.4%) than with the DCI laryngoscope (63.8%; P < 0.01). Laryngoscopy time did not differ between instruments [median (range): direct laryngoscope, 13 (5-33) s; DCI laryngoscope, 14 (6-40) s; GlideScope, 13 (5-34) s]. In contrast, tracheal intubation needed significantly more time with both video laryngoscopes [DCI laryngoscope, 27 (17-94) s, P < 0.05 and GlideScope, 33 (18-68) s, P < 0.01] than with the direct laryngoscope [22.5 (12-49) s]. Intubation failed in four cases (10%) using the direct laryngoscope and in one case (2.5%) each using the DCI laryngoscope and the GlideScope. CONCLUSION: We conclude that the video laryngoscope and GlideScope in particular may be useful instruments in the management of the predicted difficult airway.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/eja.0b013e32832d328d

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
Serocki, G., Bein, B., Scholz, J., & Dörges, V.
Venue
European Journal of Anaesthesiology
Published
2010-01
Volume
27
Issue
1
Pages
24-30
ISSN
0265-0215 (ISSN-L)
OpenAlex
W2058114963
Cited by
171
References
0
FWCI
13.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope. https://app.cochat.ai/papers/10.1097/eja.0b013e32832d328d
The paper
Serocki, G., Bein, B., Scholz, J., & Dörges, V. (2010). Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope. European Journal of Anaesthesiology. https://doi.org/10.1097/eja.0b013e32832d328d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.