The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis
Open accessAbstract
INTRODUCTION: The Glidescope(®) video-laryngoscopy appears to provide better glottic visualization than direct laryngoscopy. However, it remains unclear if it translates into increased success with intubation. METHODS: We systematically searched electronic databases, conference abstracts, and article references. We included trials in humans comparing Glidescope(®) video-laryngoscopy to direct laryngoscopy regarding the glottic view, successful first-attempt intubation, and time to intubation. We generated pooled risk ratios or weighted mean differences across studies. Meta-regression was used to explore heterogeneity based on operator expertise and intubation difficulty. RESULTS: We included 17 trials with a total of 1,998 patients. The pooled relative risk (RR) of grade 1 laryngoscopy (vs ≥ grade 2) for the Glidescope(®) was 2.0 [95% confidence interval (CI) 1.5 to 2.5]. Significant heterogeneity was partially explained by intubation difficulty using meta-regression analysis (P = 0.003). The pooled RR for nondifficult intubations of grade 1 laryngoscopy (vs ≥ grade 2) was 1.5 (95% CI 1.2 to 1.9), and for difficult intubations it was 3.5 (95% CI 2.3 to 5.5). There was no difference between the Glidescope(®) and the direct laryngoscope regarding successful first-attempt intubation or time to intubation, although there was significant heterogeneity in both of these outcomes. In the two studies examining nonexperts, successful first-attempt intubation (RR 1.8, 95% CI 1.4 to 2.4) and time to intubation (weighted mean difference -43 sec, 95% CI -72 to -14 sec) were improved using the Glidescope(®). These benefits were not seen with experts. CONCLUSION: Compared to direct laryngoscopy, Glidescope(®) video-laryngoscopy is associated with improved glottic visualization, particularly in patients with potential or simulated difficult airways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gotzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · BMJ · doi:10.1136/bmj.b2700 · Cited by 17,648
The combination of estimates from different experiments
Cochran, W. G. (1954) · Biometrics · doi:10.2307/3001666 · Cited by 5,380 · cited 1×
“0) Malik 2009(26) 22/3/0/0 2/15/6/2 22/25 (88%) 17/25 (68%) 17 (12-31) 13 (8-23) Morello 2009(33) 239/61/0/0 128/152/20/0 134/150 (89%) 95/150 (63%) NR NR Nouruzi-Sedeh 2009(14) 66/26/5/3 32/18/37/13 93/100 (93%) 51/100 (51%) 63 (30) 89 (35) Robitaille 2008(29) 10/10/0/0 0/19/1/0 NR NR NR NR Serocki 2010(24) 43/75/2/0…”
How should meta‐regression analyses be undertaken and interpreted?
Thompson, S. G., & Higgins, J. P. T. (2002) · Statistics in Medicine · doi:10.1002/sim.1187 · Cited by 3,026
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471
The appropriateness of asymmetry tests for publication bias in meta-analyses: A large survey
Ioannidis, J. P. A., & Trikalinos, T. A. (2007) · Canadian Medical Association Journal · doi:10.1503/cmaj.060410 · Cited by 1,052 · cited 1×
“8) Sun 2005(15) 75/24/1/0 59/26/15/0 94/100 (94%) 97/100 (97%) 46 (43-49) 30 (28-33) Teoh 2009(27) 78/21/1/0 58/37/5/0 91/100 (91%) 98/100 (98%) 31.”
(2005) · Circulation · doi:10.1161/circulationaha.105.166550 · Cited by 1,000
Shiga, T., Wajima, Z., Inoue, T., & Sakamoto, A. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00027 · Cited by 902
Schwartz, D. E., Matthay, M. A., & Cohen, N. H. (1995) · Anesthesiology · doi:10.1097/00000542-199502000-00007 · Cited by 676
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., & Smith, A. F. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011136.pub2 · Cited by 374
Lewis, S. R., Butler, A. R., Parker, J., Cook, T. M., Schofield-Robinson, O. J., & Smith, A. F. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex228 · Cited by 359
for the Canadian Airway Focus Group, Law, J. A., Broemling, N., Cooper, R. M., Drolet, P., Duggan, L. V., Griesdale, D. E., Hung, O. R., Jones, P. M., Kovacs, G., et al. (2013) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-013-0019-3 · Cited by 358
Self-citationGu, Y., Robert, J., Kovacs, G., Milne, A. D., Morris, I., Hung, O., MacQuarrie, K., Mackinnon, S., & Adam Law, J. (2016) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-016-0654-6 · Cited by 57
Metadata
- Authors
- Griesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T.
- Venue
- Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Published
- 2011-11-01
- Volume
- 59
- Issue
- 1
- Pages
- 41-52
- ISSN
- 0832-610X (ISSN-L)
- 1496-8975
- OpenAlex
- W1531030680
- Cited by
- 363
- References
- 36
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1007/s12630-011-9620-5
- The paper
- Griesdale, D. E. G., Liu, D., McKinney, J., & Choi, P. T. (2012). Glidescope® video-laryngoscopy versus direct laryngoscopy for endotracheal intubation: a systematic review and meta-analysis. Canadian Journal of Anesthesia/Journal canadien d'anesthésie. https://doi.org/10.1007/s12630-011-9620-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.