CoChat

Normotensive patients with obstructive sleep apnoea: changes in 24-h ambulatory blood pressure monitoring with continuous positive airway pressure treatment

Sapiña-Beltrán, Esther, Santamaria-Martos, Fernando, Benítez, Ivan, Torres, Gerard, Masa, Juan F., Sánchez-de-la-Torre, Manuel, Barbé, Ferran, Dalmases, Mireia · 2019 · Journal of Hypertension

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Continuous positive airway pressure (CPAP) treatment reduces blood pressure (BP) in obstructive sleep apnoea (OSA) and hypertensive patients, but there is a lack of data about the effects of CPAP on the BP in normotensive patients. OBJECTIVE: The aim of the study was to evaluate BP changes in normotensive OSA individuals receiving CPAP treatment. METHODS: We selected 131 normotensive outpatients with an apnoea/hypopnoea index (AHI) greater than 15 events/hour who required CPAP treatment. All patients underwent a sleep study and 24-h ambulatory BP monitoring (ABPM) at baseline and after 6 months. In addition, the patients were assessed for the presence of baseline masked hypertension, defined as office BP less than 140/90 mmHg and increased BP on 24-h ABPM (mean 24-h BP ≥130/80 mmHg). RESULTS: After 6 months of CPAP treatment, a mild reduction in all 24-h ABPM variables was observed, but only the mean 24-h DBP [-1.39 mmHg, 95% confidence interval (95% CI), -2.50 to -0.27], mean daytime DBP (-1.39 mmHg, 95% CI -2.56 to -0.22) and the mean 24-h ambulatory BP (-1.80 mmHg, 95% CI, -3.16 to -0.44) reached statistical significance. The reduction was primarily due to BP changes in individuals with masked hypertension who displayed a mean BP reduction of -4.78 mmHg (-7.25 to -2.30 mmHg). Consistent with a circadian BP pattern, a reduction in mean nocturnal BP of -4.73 mmHg (-7.39 to -2.06 mmHg) was observed at 6 months in nondippers; in contrast, the mean nocturnal BP in dippers increased by 2.61 mmHg (0.60-4.62 mmHg). CONCLUSION: Our findings suggest that the CPAP effects may be different in normotensive outpatients depending on the presence of undiagnosed masked hypertension and the dipping pattern. Therefore, it is important to consider measuring ABPM in this type of patient.

Overview

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000001934

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 41 references

Cited by

Metadata

Authors
Sapiña-Beltrán, E., Santamaria-Martos, F., Benítez, I., Torres, G., Masa, J. F., Sánchez-de-la-Torre, M., Barbé, F., & Dalmases, M.
Affiliations
  • Universitat de Lleida (ES)
  • Centro de Investigación Biomédica en Red de Enfermedades Respiratorias (ES)
Corresponding author
Sapiña-Beltrán, Esther
Venue
Journal of Hypertension
Published
2019-04
Volume
37
Issue
4
Pages
720-727
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2894115098
Cited by
28
References
41
Citations by year
2026: 1 · 2025: 2 · 2024: 1 · 2023: 2 · 2022: 5 · 2021: 5 · 2020: 4 · 2019: 8
FWCI
2.93
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
obstructive sleep apnea, continuous positive airway pressure, normotensive subjects, masked hypertension, ambulatory blood pressure monitoring, nocturnal blood pressure dipping, circadian blood pressure rhythm, diastolic blood pressure reduction
MeSH terms
Adult, Blood Pressure, Circadian Rhythm, Female, Humans, Male, Middle Aged, Polysomnography, Blood Pressure Monitoring, Ambulatory, Sleep Apnea, Obstructive, Continuous Positive Airway Pressure, Masked Hypertension

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.