Blood pressure response to CPAP treatment in subjects with obstructive sleep apnoea: the predictive value of 24-h ambulatory blood pressure monitoring
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The reduction in blood pressure (BP) with continuous positive airway pressure (CPAP) is modest and highly variable. In this study, we identified the variables that predict BP response to CPAP. 24-h ambulatory BP monitoring (ABPM), C-reactive protein (CRP), leptin, adiponectin and 24-h urinary catecholamine were measured before and after 6 months of CPAP in obstructive sleep apnoea (OSA) patients. Overall, 88 middle-aged, obese male patients with severe OSA (median apnoea–hypopnoea index 42 events·h−1) were included; 28.4% had hypertension. 62 patients finished the study, and 60 were analysed. The daytime diastolic BP (−2 mmHg) and norepinephrine (−109.5 nmol·day-1) were reduced after CPAP, but no changes in the 24-h BP, night-time BP, dopamine, epinephrine, CRP, leptin or adiponectin were detected. The nocturnal normotension was associated with an increased night-time-BP (+4 mmHg) after CPAP, whereas nocturnal hypertension was associated with a reduction of 24-h BP (−3 mmHg). A multivariate linear regression model showed differential night-time BP changes after CPAP. Specifically, low night-time heart rate (<68 bpm) and BP dipper profile were associated with increased night-time BP and new diagnosis of nocturnal hypertension. Our results suggest that nocturnal hypertension, circadian BP pattern and night-time heart rate could be clinical predictors of BP response to CPAP and support the usefulness of 24-h ABPM for OSA patients before treatment initiation. These results need to be confirmed in further studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Marin, J. M., Carrizo, S. J., Vicente, E., & Agusti, A. G. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71141-7 · Cited by 4,678
Nieto, F. J. (2000) · JAMA · doi:10.1001/jama.283.14.1829 · Cited by 3,369
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Dolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227
McNicholas, W. T., Bonsignore, M. R., & the Management Committee of EU COST ACTION B26 (2007) · European Respiratory Journal · doi:10.1183/09031936.00027406 · Cited by 911
Barbé, F., Durán-Cantolla, J., Sánchez-de-la-Torre, M., Martínez-Alonso, M., Carmona, C., Barceló, A., Chiner, E., Masa, J. F., Gonzalez, M., Marín, J. M., et al. (2012) · JAMA · doi:10.1001/jama.2012.4366 · Cited by 792
Self-citationMartínez-García, M.-A., Capote, F., Campos-Rodríguez, F., Lloberes, P., Díaz de Atauri, M. J., Somoza, M., Masa, J. F., González, M., Sacristán, L., Barbé, F., et al. (2013) · JAMA · doi:10.1001/jama.2013.281250 · Cited by 685
Self-citationThe different clinical faces of obstructive sleep apnoea: a cluster analysis
Ye, L., Pien, G. W., Ratcliffe, S. J., Björnsdottir, E., Arnardottir, E. S., Pack, A. I., Benediktsdottir, B., & Gislason, T. (2014) · European Respiratory Journal · doi:10.1183/09031936.00032314 · Cited by 474
Cited by
Diretrizes Brasileiras de Hipertensão Arterial – 2020
Barroso, W. K. S., Rodrigues, C. I. S., Bortolotto, L. A., Mota-Gomes, M. A., Brandão, A. A., Feitosa, A. D. D. M., Machado, C. A., Poli-de-Figueiredo, C. E., Amodeo, C., Mion, D., et al. (2021) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20201238 · Cited by 1,068
Zinchuk, A., & Yaggi, H. K. (2020) · Chest · doi:10.1016/j.chest.2019.09.002 · Cited by 289
Pengo, M. F., Soranna, D., Giontella, A., Perger, E., Mattaliano, P., Schwarz, E. I., Lombardi, C., Bilo, G., Zambon, A., Steier, J., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.01945-2019 · Cited by 178
Edwards, B. A., Redline, S., Sands, S. A., & Owens, R. L. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201901-0014tr · Cited by 164
“For example, some patients with OSA have increased blood pressure when CPAP is applied (21).”
BackgroundMcNicholas, W. T. (2019) · Expert Review of Respiratory Medicine · doi:10.1080/17476348.2019.1575204 · Cited by 44
“edge of 24-hour blood pressure profile may improve the prediction of treatment response [35].”
Background
Metadata
- Authors
- Castro-Grattoni, A. L., Torres, G., Martínez-Alonso, M., Barbé, F., Turino, C., Sánchez-de-la-Torre, A., Cortijo, A., Duran-Cantolla, J., Egea, C., Cao, G., & Sánchez-de-la-Torre, M.
- Venue
- European Respiratory Journal
- Publisher
- European Respiratory Society (ERS)
- Published
- 2017-10
- Volume
- 50
- Issue
- 4
- Pages
- 1700651
- ISSN
- 0903-1936 (ISSN-L)
- 1399-3003
- OpenAlex
- W2761595233
- Cited by
- 58
- References
- 18
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood pressure response to CPAP treatment in subjects with obstructive sleep apnoea: the predictive value of 24-h ambulatory blood pressure monitoring. https://app.cochat.ai/papers/10.1183/13993003.00651-2017
- The paper
- Castro-Grattoni, A. L., Torres, G., Martínez-Alonso, M., Barbé, F., Turino, C., Sánchez-de-la-Torre, A., Cortijo, A., Duran-Cantolla, J., Egea, C., Cao, G., & Sánchez-de-la-Torre, M. (2017). Blood pressure response to CPAP treatment in subjects with obstructive sleep apnoea: the predictive value of 24-h ambulatory blood pressure monitoring. European Respiratory Journal. https://doi.org/10.1183/13993003.00651-2017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.