Cited by 67Blood Pressure and Hypertension StudiesAtrial Fibrillation Management and OutcomesCardiovascular Health and Disease Prevention

Blood pressure measurement in atrial fibrillation: review and meta-analysis of evidence on accuracy and clinical relevance

Stergiou, George S., Kyriakoulis, Konstantinos G., Stambolliu, Emelina, Destounis, Antonios, Karpettas, Nikos, Kalogeropoulos, Petros, Kollias, Anastasios·2019·Journal of Hypertension

Abstract

: Atrial fibrillation (AF) often coexists with hypertension in the elderly and multiplies the risk of stroke and death. Blood pressure (BP) measurement in patients with AF is difficult and uncertain and has been a classic exclusion criterion in hypertension clinical trials leading to limited research data. This article reviews the evidence on the accuracy of BP measurement in AF performed using different methods (office, ambulatory, home) and devices (auscultatory, oscillometric) and its clinical relevance in predicting cardiovascular damage. The current evidence suggests the following: (i) Interobserver and intra-observer variation in auscultatory BP measurement is increased in AF because of increased beat-to-beat BP variability and triplicate measurement is required; (ii) Data from validation studies of automated electronic BP monitors in AF are limited and methodologically heterogeneous and suggest reasonable accuracy in measuring SBP and a small yet consistent overestimation of DBP; (iii) 24-h ambulatory BP monitoring is feasible in AF, with similar proportion of errors as in individuals without AF; (iv) both auscultatory and automated oscillometric BP measurements appear to be clinically relevant in AF, providing similar associations with intra-arterial BP measurements and with indices of preclinical cardiac damage as in patients without AF, and predict cardiovascular events and death; (v) Screening for AF in the elderly using an AF-specific algorithm during routine automated office, home or ambulatory BP measurement has high diagnostic accuracy. In conclusion, in AF patients, BP measurement is important, reliable, and clinically relevant and should not be neglected in clinical research and in practice.

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000002201

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Stergiou, G. S., Kyriakoulis, K. G., Stambolliu, E., Destounis, A., Karpettas, N., Kalogeropoulos, P., & Kollias, A.
Affiliations
American National Standards Institute (US)
Corresponding author
Stergiou, George S.
Venue
Journal of Hypertension
Published
2019-12
Volume
37
Issue
12
Pages
2430-2441
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2967579401
Cited by
67
References
5
Citations by year
2026: 11 · 2025: 15 · 2024: 13 · 2023: 7 · 2022: 8 · 2021: 7 · 2020: 5 · 2019: 1
FWCI
0.95
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
atrial fibrillation, blood pressure measurement, hypertension, ambulatory blood pressure monitoring, home blood pressure monitoring, auscultatory blood pressure measurement, oscillometric blood pressure measurement, automated blood pressure monitors, interobserver variability, beat-to-beat blood pressure variability, cardiovascular risk prediction, stroke risk, older adults, atrial fibrillation screening
MeSH terms
Atrial Fibrillation, Blood Pressure, Blood Pressure Determination, Humans

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review