Short-term reproducibility of ambulatory blood pressure measurements: a systematic review and meta-analysis of 35 observational studies
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Objective: A systematic review on the reproducibility of ambulatory blood pressure measurements (ABPM) has not yet been conducted. This meta-analysis compared 24-h/daytime/night-time SBP and DBP mean values and SBP/DBP nocturnal dipping status from ABPMs in participants with or without hypertension. Methods: Ovid MEDLINE, EMBASE, and CINAHL Complete databases were searched for articles published before 3 May 2019. Eligible studies reporting a 24-h ABPM repeated at least once within 1 month were included. The mean daytime/night-time/24-h BP values, percentage of nocturnal dipping, and proportion of nondippers were compared between the first and second day of measurements, and the proportion of participants with inconsistent dipping status were estimated using a random effect model. Results: Population-based analysis found a 0–1.1 mmHg difference between the first and second ABPM for 24-h/daytime/night-time SBP and DBP and 0–0.5% for percentage of SBP/DBP nocturnal dipping. The proportion of non-dippers was not different between the first and second ABPM. Intra-individual analysis found that the 95% limit of agreements (LOA) for SBP/DBP were wide and the 95% LOA for daytime SBP, common reference to diagnose hypertension, ranged −16.7 to 18.4 mmHg. Similarly, 32% of participants had inconsistent nocturnal dipping status. Conclusion: ABPM had excellent reproducibility at the population level, favouring its application for research purposes; but reproducibility of intra-individual BP values and dipping status from a 24-h ABPM was limited. The available evidence was limited by the lack of high-quality studies and lack of studies in non-Western populations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Global Burden of Hypertension and Systolic Blood Pressure of at Least 110 to 115 mm Hg, 1990-2015
Forouzanfar, M. H., Liu, P., Roth, G. A., Ng, M., Biryukov, S., Marczak, L., Alexander, L., Estep, K., Hassen Abate, K., Akinyemiju, T. F., et al. (2017) · JAMA · doi:10.1001/jama.2016.19043 · Cited by 2,381 · cited 1×
“0000000000002522 H ypertension is the most common chronic condition, contributing to physical complications and substantial burden to healthcare systems [1].”
BackgroundExercise Training for Blood Pressure: A Systematic Review and Meta‐analysis
Cornelissen, V. A., & Smart, N. A. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.112.004473 · Cited by 1,683 · cited 1×
“However, BP is known to be a volatile parameter and is affected by a number of factors, such as season [38], temperature [38], emotional state [39], and exercise level [40].”
BackgroundEuropean Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Roerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216 · cited 2×
“Quality assessment There is no standard tool for quality assessment for reproducibility research [15].”
Method
Cited by
Flynn, J. T., Urbina, E. M., Brady, T. M., Baker-Smith, C., Daniels, S. R., Hayman, L. L., Mitsnefes, M., Tran, A., Zachariah, J. P., & on behalf of the Atherosclerosis, H. (2022) · Hypertension · doi:10.1161/hyp.0000000000000215 · Cited by 202
Lee, E. K., Poon, P., Yu, C., Lee, V. W., Chung, V. C., & Wong, S. Y. (2022) · The Journal of Clinical Hypertension · doi:10.1111/jch.14482 · Cited by 38
Self-citationStergiou, G. S., Bountzona, I., Alamara, C., Vazeou, A., Kollias, A., & Ntineri, A. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16531 · Cited by 31
Reproducibility study of nocturnal blood pressure dipping in patients with high cardiovascular risk
Burgos‐Alonso, N., Ruiz Arzalluz, M. V., Garcia‐Alvarez, A., Fernandez‐Fernandez de Quincoces, D., & Grandes, G. (2021) · The Journal of Clinical Hypertension · doi:10.1111/jch.14222 · Cited by 19
“29-31 In contrast, we report data from 225 patients who underwent ABPM on four occasions over a period of 5 months.”
BackgroundMethodInfluential
Metadata
- Authors
- Bo, Y., Kwok, K.-O., Chung, V. C.-H., Yu, C.-P., Tsoi, K. K.-F., Wong, S. Y.-S., & Lee, E. K.-P.
- Venue
- Journal of Hypertension
- Published
- 2020-06-15
- Volume
- 38
- Issue
- 11
- Pages
- 2095-2109
- ISSN
- 0263-6352 (ISSN-L)
- 1473-5598
- OpenAlex
- W3036675503
- Cited by
- 73
- References
- 5
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Short-term reproducibility of ambulatory blood pressure measurements: a systematic review and meta-analysis of 35 observational studies. https://app.cochat.ai/papers/10.1097/hjh.0000000000002522
- The paper
- Bo, Y., Kwok, K.-O., Chung, V. C.-H., Yu, C.-P., Tsoi, K. K.-F., Wong, S. Y.-S., & Lee, E. K.-P. (2020). Short-term reproducibility of ambulatory blood pressure measurements: a systematic review and meta-analysis of 35 observational studies. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000002522
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.