CoChat

Effect of telemonitoring and home blood pressure monitoring on blood pressure reduction in hypertensive adults: a network meta-analysis

The DOI matches its Crossref record; 36 of the 38 references it cites were found in a registry or an index.

Abstract

Introduction: Telemonitoring and home blood pressure monitoring (HBPM) are becoming popular approaches for managing hypertension. They are believed to improve patient compliance as compared to the usual care monitoring. This network meta-analysis was undertaken to compare blood pressure (BP) reduction following telemonitoring, HBPM and usual care BP monitoring approaches. Methods: PubMed and clinicaltrial.gov were searched till 15 May 2024 for randomized controlled trials (RCTs) comparing telemonitoring, HBPM and usual care monitoring for reduction in BP and the postintervention BP in hypertensive adults. Results: A network meta-analysis with 24 RCTs was performed using MetaInsight. Telemonitoring produced a significantly greater reduction in the systolic blood pressure (SBP) (–3.69 mmHg [95% CI –5.82; –1.57, P < 0.001]) and the diastolic blood pressure (DBP) (–1.82 mmHg [95% CI –2.98 to –0.67, P < 0.001]) as compared to the usual care monitoring. Home BP monitoring also produced a greater lowering of SBP (–2.73 mmHg [95% CI –5.69 to 0.22, P = 0.069]) and DBP (–2.09 mm Hg [95% CI –3.66 to –0.52, P < 0.001]) than usual care, with a significant reduction in the DBP alone. The postintervention SBP and DBP were also lower in the telemonitoring and the HBPM groups than the usual care group. However, there was no significant difference between the SBP and the DBP reductions in the telemonitoring and the HBPM groups. Conclusion: Telemonitoring and HBPM may be more useful in controlling BP as compared to usual care management alone. However, more direct studies comparing telemonitoring with HBPM are needed in the future.

Overview

Integrity signals

Registry

Crossref · 10.1097/hjh.0000000000004008

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 36 references

Cited by

See all 8

Metadata

Authors
Grover, S., Mishra, H. P., Gupta, R., & Gupta, L. K.
Affiliations
  • Lady Hardinge Medical College (IN)
  • University College of Medical Sciences (IN)
Corresponding author
  • Gupta, Rachna
  • Gupta, Lalit K.
Venue
Journal of Hypertension
Published
2025-03-27
Volume
43
Issue
7
Pages
1091-1098
ISSN
  • 0263-6352 (ISSN-L)
  • 1473-5598
OpenAlex
W4408978827
Cited by
8
References
38
Citations by year
2026: 6 · 2025: 2
FWCI
5.54
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Telemedicine and Telehealth Implementation
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
Keywords
remote patient monitoring, home blood pressure monitoring, hypertension, blood pressure reduction, systolic blood pressure, diastolic blood pressure, medication adherence, antihypertensive therapy
MeSH terms
Adult, Blood Pressure, Humans, Hypertension, Randomized Controlled Trials as Topic, Telemedicine, Blood Pressure Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of telemonitoring and home blood pressure monitoring on blood pressure reduction in hypertensive adults: a network meta-analysis. https://app.cochat.ai/papers/10.1097/hjh.0000000000004008
The paper
Grover, S., Mishra, H. P., Gupta, R., & Gupta, L. K. (2025). Effect of telemonitoring and home blood pressure monitoring on blood pressure reduction in hypertensive adults: a network meta-analysis. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000004008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.