Abstract

OBJECTIVE: To explore the differences between oscillometric and auscultatory measurements. METHOD: From a simulator evaluation of a non-invasive blood pressure (NIBP) device regenerating 242 oscillometric blood pressure waveforms from 124 subjects, 10 waveforms were selected based on the differences between the NIBP (oscillometric) and auscultatory pressure measurements. Two waveforms were selected for each of five criteria: systolic over and underestimation; diastolic over and underestimation; and close agreement for both systolic and diastolic pressures. The 10 waveforms were presented to seven different devices and the oscillometric-auscultatory pressure differences were compared between devices and with the oscillometric waveform shapes. RESULTS: Consistent patterns of waveform-dependent over and underestimation of systolic and diastolic pressures were shown for all seven devices. The mean and standard deviation, for all devices, of oscillometric-auscultatory pressure differences were: for the systolic overestimated waveforms, 36 +/- 28/-6 +/- 3 and 23 +/- 2/-1 +/- 3 mmHg (systolic/diastolic differences); for systolic underestimated waveforms, -21 +/- 5/-4 +/- 3 and -11 +/- 4/-3 +/- 3 mmHg; for diastolic overestimated waveforms, 3 +/- 4/12 +/- 5 and 17 +/- 6/10 +/- 2 mmHg; for diastolic underestimated waveforms, 1 +/- 4/-22 +/- 4 and -9 +/- 6/-29 +/- 4 mmHg; and for the two waveforms with good agreement, 0 +/- 6/0 +/- 3 and -2 +/- 4/-4 +/- 3 mmHg. Waveforms for which devices showed good oscillometric and auscultatory agreement had smooth envelopes with clearly defined peaks, compared with the broader plateau and complex shapes of those waveforms for which devices over or underestimated pressures. CONCLUSION: By increasing the understanding of the characteristics and limitations of the oscillometric method and the effects of waveform shape on pressure measurements, simulator evaluation should lead to improvements in NIBP devices.

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e3282f06ec7

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Different methods to construct the oscillometric waveform envelope and individual differences in envelope shape can lead to different estimated BP values.

    “Furthermore, different methods used to construct the oscillometric waveform envelope, as well as individual differences in the shape of the waveform envelope, can lead to different estimated BP values [55, 56].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Amoore, J. N., Lemesre, Y., Murray, I. C., Mieke, S., King, S. T., Smith, F. E., & Murray, A.
Affiliations
  • Edinburgh Royal Infirmary (GB)
  • Université de la Méditerranée Aix-Marseille II (FR)
  • University of Edinburgh (GB)
  • Physikalisch-Technische Bundesanstalt (DE)
  • Freeman Hospital (GB)
Corresponding author
Amoore, John N
Venue
Journal of Hypertension
Published
2008-01
Volume
26
Issue
1
Pages
35-43
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2021784551
Cited by
56
References
2
Citations by year
2025: 3 · 2024: 1 · 2023: 4 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 4 · 2018: 4 · 2017: 5 · 2016: 1 · 2015: 7 · 2014: 1 · 2013: 4 · 2012: 4
FWCI
2.42
Type
journal article
Language
en
Open access
Locations
  • Journal of Hypertension (publishedVersion)
  • PubMed (publishedVersion)
  • Newcastle University ePrints (Newcastle Univesity)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
oscillometric blood pressure measurement, auscultatory blood pressure measurement, blood pressure measurement agreement, simulator evaluation, waveform envelope
MeSH terms
Adult, Aged, Auscultation, Blood Pressure, Blood Pressure Determination, Female, Humans, Male, Middle Aged, Oscillometry, Software, Reproducibility of Results, Blood Pressure Monitors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review