Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 319

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

A new oscillometric method for assessment of arterial stiffness: comparison with tonometric and piezo-electronic methods

Baulmann, Johannes, Schillings, Ulrich, Rickert, Susanna, Uen, Sakir, Düsing, Rainer, Illyes, Miklos, Cziraki, Attila, Nickenig, Georg, Mengden, Thomas·2008·Journal of Hypertension

Abstract

INTRODUCTION: Pulse wave velocity (PWV) and augmentation index (AIx) are parameters of arterial stiffness and wave reflection. PWV and AIx are strong indicators for cardiovascular risk and are used increasingly in clinical practice. Previous systems for assessment of PWV and AIx are investigator dependent and time consuming. The aim of this study was to validate the new oscillometric method (Arteriograph) for determining PWV and AIx by comparing it to two clinically validated, broadly accepted tonometric and piezo-electronic systems (SphygmoCor and Complior). DESIGN AND METHOD: PWV and AIx were measured up to five times in 51 patients with the SphygmoCor, Complior and Arteriograph. In 35 patients, the measurements were repeated after 1 week in a second session using the same protocol. RESULTS: The correlations of the PWV as assessed with the Arteriograph with the values obtained using the SphygmoCor (r = 0.67, P < 0.001) and the Complior (r = 0.69, P < 0.001) were highly significant. Variability and reproducibility for PWV were best for the Arteriograph, followed by Complior and SphygmoCor. AIx (SphygmoCor versus Arteriograph) were very closely correlated (r = 0.92, P < 0.001). PERSPECTIVES: The Arteriograph is a new, easy-to-use and time-effective method for assessing arterial stiffness and wave reflection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/hjh.0b013e3282f314f7

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 319

Metadata

Authors
Baulmann, J., Schillings, U., Rickert, S., Uen, S., Düsing, R., Illyes, M., Cziraki, A., Nickenig, G., & Mengden, T.
Venue
Journal of Hypertension
Published
2008-03
Volume
26
Issue
3
Pages
523-528
ISSN
0263-6352 (ISSN-L)
OpenAlex
W2133068045
Cited by
319
References
22
FWCI
11.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A new oscillometric method for assessment of arterial stiffness: comparison with tonometric and piezo-electronic methods. https://app.cochat.ai/papers/10.1097/hjh.0b013e3282f314f7
The paper
Baulmann, J., Schillings, U., Rickert, S., Uen, S., Düsing, R., Illyes, M., Cziraki, A., Nickenig, G., & Mengden, T. (2008). A new oscillometric method for assessment of arterial stiffness: comparison with tonometric and piezo-electronic methods. Journal of Hypertension. https://doi.org/10.1097/hjh.0b013e3282f314f7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.