Preventing misdiagnosis of ambulatory hypertension: algorithm using office and home blood pressures
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: An algorithm for making a differential diagnosis between sustained and white coat hypertension (WCH) has been proposed - patients with office hypertension undergo home blood pressure monitoring (HBPM) and those with normal HBP levels undergo ambulatory blood pressure monitoring (ABPM). We tested whether incorporating an upper office blood pressure (OBP) cut-off in the algorithm, higher than the traditional 140/90 mmHg, reduces the need for HBPM and ABPM. METHODS: Two hundred twenty-nine normotensive and untreated mildly hypertensive participants (mean age 52.5 +/- 14.6 years, 54% female participants) underwent OBP measurements, HBPM, and 24-h ABPM. Using the algorithm, sensitivity, specificity, and positive and negative predictive values (PPV, NPV) for sustained hypertension and WCH were assessed. We then modified the algorithm utilizing a systolic and diastolic OBP cut-off at a specificity of 95% for ambulatory hypertension - those with office hypertension but OBP levels below the upper cut-off underwent HBPM and subsequent ABPM, if appropriate. RESULTS: Using the original algorithm, sensitivity and PPV for sustained hypertension were 100% and 93.8%, respectively. Despite a specificity of 44.4%, NPV was 100%. These values correspond to specificity, NPV, sensitivity, and PPV for WCH, respectively. Using the modified algorithm, the diagnostic accuracy for sustained hypertension and WCH did not change. However, far fewer participants needed HBPM (29 vs. 84) and ABPM (8 vs. 15). CONCLUSION: In this sample, the original and modified algorithms are excellent at diagnosing sustained hypertension and WCH. However, the latter requires far fewer participants to undergo HBPM and ABPM. These findings have important implications for the cost-effective diagnosis of sustained hypertension and WCH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O'Brien, E., Asmar, R., Beilin, L., Imai, Y., Mallion, J.-M., Mancia, G., Mengden, T., Myers, M., Padfield, P., Palatini, P., et al. (2003) · Journal of Hypertension · doi:10.1097/00004872-200305000-00001 · Cited by 1,655
Self-citationBobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842 · cited 1×
“As with ABP, the risks of target end-organ damage and cardiovascular events are more strongly associated with home blood pressure (HBP) than with OBP [9,10,11].”
BackgroundMancia, G., Facchetti, R., Bombelli, M., Grassi, G., & Sega, R. (2006) · Hypertension · doi:10.1161/01.hyp.0000215363.69793.bb · Cited by 691
Ambulatory Blood Pressure and Mortality: A Population-Based Study
Hansen, T. W., Jeppesen, J., Rasmussen, S., Ibsen, H., & Torp-Pedersen, C. (2005) · Hypertension · doi:10.1161/01.hyp.0000160402.39597.3b · Cited by 317
Pickering, T. G., Miller, N. H., Ogedegbe, G., Krakoff, L. R., Artinian, N. T., & Goff, D. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.189011 · Cited by 294 · cited 3×
“A recently published systematic review [25] and an AHA/ASH/PCNA scientific statement [26] concluded that the minimum number of home measurements, needed to obtain a reliable estimate of a subject’s usual blood pressure, is 12.”
Self-citationHome Blood Pressure Measurement
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., & de Leeuw, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.058 · Cited by 212
Stergiou, G. S., Nasothimiou, E., Giovas, P., Kapoyiannis, A., & Vazeou, A. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328301c411 · Cited by 114 · cited 1×
“Similar diagnostic accuracy of HBPM in predicting ambulatory hypertension or normotension in those with office hypertension has been observed in other studies [33,34, 35].”
ResultStaessen, J. A., Thijs, L., Ohkubo, T., Kikuya, M., Richart, T., Boggia, J., Adiyaman, A., Dechering, D. G., Kuznetsova, T., Thien, T., et al. (2008) · Blood Pressure Monitoring · doi:10.1097/mbp.0b013e3283108f93 · Cited by 56 · cited 1×
“However, it is generally accepted that the diagnostic threshold for both HBP and awake ABP is 135/85 mmHg [52,53].”
Background
Cited by
Hodgkinson, J., Mant, J., Martin, U., Guo, B., Hobbs, F. D. R., Deeks, J. J., Heneghan, C., Roberts, N., & McManus, R. J. (2011) · BMJ · doi:10.1136/bmj.d3621 · Cited by 370
Writing Committee Members*, Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., et al. (2025) · Hypertension · doi:10.1161/hyp.0000000000000249 · Cited by 310
Self-citationJones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., Bress, A. P., et al. (2025) · JACC · doi:10.1016/j.jacc.2025.05.007 · Cited by 280
Self-citationWriting Committee Members*, Jones, D. W., Ferdinand, K. C., Taler, S. J., Johnson, H. M., Shimbo, D., Abdalla, M., Altieri, M. M., Bansal, N., Bello, N. A., et al. (2025) · Circulation · doi:10.1161/cir.0000000000001356 · Cited by 213
Self-citationHome Blood Pressure Monitoring in the Diagnosis and Treatment of Hypertension: A Systematic Review
Stergiou, G. S., & Bliziotis, I. A. (2011) · American Journal of Hypertension · doi:10.1038/ajh.2010.194 · Cited by 182
Metadata
- Authors
- Shimbo, D., Kuruvilla, S., Haas, D., Pickering, T. G., Schwartz, J. E., & Gerin, W.
- Venue
- Journal of Hypertension
- Published
- 2009-09
- Volume
- 27
- Issue
- 9
- Pages
- 1775-1783
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W1972375259
- Cited by
- 28
- References
- 8
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.