Cited by 6Radiation Dose and ImagingAdvanced Radiotherapy TechniquesRadiology practices and education

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review

Alzyoud, Kholoud, Al-Murshedi, Sadeq, England, Andrew·2024·Health Physics

Abstract

A comprehensive search was performed to examine the literature on diagnostic reference levels (DRL) for computed tomography (CT) and radiography examinations that are performed routinely in Jordan. EBSCO, Scopus, and Web of Science were used for the search. The acronym “DRL” and the additional phrase “dose reference levels” were used to search for articles in literature. Seven papers that reported DRL values for radiography and CT scans in Jordan were identified. One study reported DRLs for conventional radiography, two studies reported CT DRLs in pediatrics, and the remaining four studies provided DRL values for adult CT scans. The most popular techniques for determining the DRLs were the entrance surface dose, volume CT dose index (CTDI vol ), and dose-length product (DLP) values. Variations in Jordanian DRL values were noted across both modalities. Lower radiation doses and less variation in DRL values may be achieved by educating and training radiographers to better understand dose reduction strategies. To limit dose variance and enable dosage comparison, CT DRLs must be standardized in accordance with the guidelines of the International Commission on Radiological Protection (ICRP).

Overview

Integrity signals

Registry

Crossref · 10.1097/hp.0000000000001778

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Research works printed but not linked: 2

  1. 2008, European guidance on estimating population doses from medical x-ray procedures, Radiat Protect, 154, 90
  2. 1998, Pediatric effective doses in diagnostic radiology, In: 44th annual scientific meeting of Canadian Organization of Medical Physicists; London, Ontario, Canada[online], 114

Cited by

Sorted by citations

Metadata

Authors
Alzyoud, K., Al-Murshedi, S., & England, A.
Affiliations
  • Hashemite University (JO)
  • AL-Zahraa University for Women, College of Health and Medical Technology, Karbala, Iraq
  • University College Cork (IE)
Corresponding author
Alzyoud, Kholoud
Venue
Health Physics
Published
2024-03
Volume
126
Issue
3
Pages
156-162
ISSN
  • 0017-9078 (ISSN-L)
  • 1538-5159
OpenAlex
W4391123206
Cited by
6
References
24
Citations by year
2026: 2 · 2025: 4
FWCI
0.39
Type
journal article
Language
en
Open access
closed
Locations
  • Health Physics (publishedVersion)
  • PubMed (publishedVersion)
  • Cork Open Research Archive (University College Cork, Ireland) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
Keywords
diagnostic reference levels, radiation dose, computed tomography, radiography, Jordan, pediatric CT, entrance surface dose, volume CT dose index, dose-length product, dose reduction strategies, dose standardization
MeSH terms
Diagnostic Reference Levels, Adult, Child, Humans, Jordan, Radiation Protection, Tomography, X-Ray Computed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review