INTRAVITREAL INJECTION TECHNIQUE AND MONITORING: Updated Guidelines of an Expert Panel

Avery, Robert L., Bakri, Sophie J., Blumenkranz, Mark S., Brucker, Alexander J., Cunningham, Emmett T., D'Amico, Donald J., Dugel, Pravin U., Flynn, Harry W., Freund, K. Bailey, Haller, Julia A., Jumper, J. Michael, Liebmann, Jeffrey M., McCannel, Colin A., Mieler, William F., Ta, Christopher N., Williams, George A.·2014·Retina

Abstract

In Brief Purpose: To review evidence and provide updated guidelines on intravitreal (IVT) injection technique and monitoring. Methods: A review of the published literature on IVT injection from 2004 to 2014 formed the basis for round table deliberations by an expert panel of ophthalmologists. Results: The dramatic increase in the number of IVT injections has been accompanied by a comparable increase in evidence surrounding IVT practice patterns and techniques. The expert panel identified a number of areas that have evolved since publication of the original IVT injection guidelines in 2004, the most notable of which were a lack of evidence to support the routine use of pre-, peri-, and postinjection antibiotics to reduce the risk of endophthalmitis, and the role of aerosolized droplets containing oral contaminants from the patient and/or providers as a potential source of infection. The panel emphasized the continued importance of applying povidone–iodine to and avoiding eyelid contact with the intended injection site and needle. Conclusion: Updated guidelines on IVT injection technique and monitoring are proposed based on a review of published literature and expert panel deliberations. Use of intravitreal injections and the evidence surrounding injection safety and techniques have expanded dramatically since publication of the initial intravitreal injection guidelines in 2004. An expert panel recently reconvened to evaluate the growing evidence on intravitreal injection techniques and monitoring and to provide updated consensus guidelines.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/iae.0000000000000399

Cites

71 of 71 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 71 references

Cited by

See all 266

Metadata

Authors
Avery, R. L., Bakri, S. J., Blumenkranz, M. S., Brucker, A. J., Cunningham, E. T., D'Amico, D. J., Dugel, P. U., Flynn, H. W., Freund, K. B., Haller, J. A., Jumper, J. M., Liebmann, J. M., McCannel, C. A., Mieler, W. F., Ta, C. N., & Williams, G. A.
Venue
Retina
Published
2014-12
Volume
34
Issue
Supplement 12
Pages
S1-S18
ISSN
0275-004X (ISSN-L)
OpenAlex
W2330800912
Cited by
266
References
71
FWCI
15.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: INTRAVITREAL INJECTION TECHNIQUE AND MONITORING: Updated Guidelines of an Expert Panel. https://app.cochat.ai/papers/10.1097/iae.0000000000000399
The paper
Avery, R. L., Bakri, S. J., Blumenkranz, M. S., Brucker, A. J., Cunningham, E. T., D'Amico, D. J., Dugel, P. U., Flynn, H. W., Freund, K. B., Haller, J. A., Jumper, J. M., Liebmann, J. M., McCannel, C. A., Mieler, W. F., Ta, C. N., & Williams, G. A. (2014). INTRAVITREAL INJECTION TECHNIQUE AND MONITORING: Updated Guidelines of an Expert Panel. Retina. https://doi.org/10.1097/iae.0000000000000399

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.