METAANALYSIS OF REAL-WORLD OUTCOMES OF INTRAVITREAL RANIBIZUMAB FOR THE TREATMENT OF NEOVASCULAR AGE-RELATED MACULAR DEGENERATION
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
PURPOSE: To report the efficacy and safety of intravitreal ranibizumab for neovascular age-related macular degeneration (nAMD) in real-world practice. METHODS: Metaanalysis of ∼26,360 patients from 42 real-world observational studies reporting outcomes of intravitreal ranibizumab for nAMD published between 2007 and 2015. Baseline demographics, lesion type, and visual acuity (VA) were recorded. The weighted mean was calculated for change in VA and frequency of injections and visits during year 1, year 2, and ≥3 years. Local and systemic adverse events were recorded. RESULTS: The mean change in VA for patients receiving a treat-and-extend regimen was +8.8 (95% confidence interval [CI]: 5.8 to 11.8), +6.7 (95% CI: 3.2 to 10.1), and +5.4 (95% CI: -4.1 to 14.9) Early Treatment Diabetic Retinopathy Study (ETDRS) letters at 1 year (n = 1,539), 2 years (n = 2,521), and ≥3 years (n = 1,298), in comparison with +3.5 (95% CI: 2.0 to 5.0), +1.3 (95% CI: -1.6 to 4.2), and -1.9 (95% CI: -9.8 to 6.0) ETDRS letters for pro re nata at 1 year (n = 20,247), 2 years (n = 14,408), and ≥3 years (n = 11,714). Treat-and-extend patients received on average more injections (6.9 vs. 4.7) but had fewer visits (7.6 vs. 9.2) in the first year. Baseline characteristics were similar between the regimens. The reported rate of endophthalmitis was 17 of 66,176 intravitreal injections (0.026%). CONCLUSION: Intravitreal ranibizumab for nAMD prevents severe visual loss in real-world practice. Patients can achieve visual gain from baseline, but the extent to which these are maintained in the long term may depend on the frequency of injections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
GRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305 · cited 1×
“The selected studies are observational in nature and therefore provide low to moderate overall quality of evidence based on the Grading of Recommendations Assessment, Development and Evaluation classification.(6)”
BackgroundConducting Meta-Analyses in R with the metafor Package
Viechtbauer, W. (2010) · Journal of Statistical Software · doi:10.18637/jss.v036.i03 · Cited by 20,464 · cited 2×
“The proportional reduction in variance was calculated to estimate the amount of heterogeneity that can be accounted for by the moderators, which can be thought of as a pseudo R2 statistic.(8) When studies did not report the standard deviation, these values were imputed via multiple imputations and model results pooled.”
BackgroundMethodmice: Multivariate Imputation by Chained Equations in R
Buuren, S. V., & Groothuis-Oudshoorn, K. (2011) · Journal of Statistical Software · doi:10.18637/jss.v045.i03 · Cited by 13,870 · cited 1×
“3 and the mice (for multiple imputations) and metafor (for random- and mixed-effects models) packages.(8,11,12)”
BackgroundRanibizumab for Neovascular Age-Related Macular Degeneration
Rosenfeld, P. J., Brown, D. M., Heier, J. S., Boyer, D. S., Kaiser, P. K., Chung, C. Y., & Kim, R. Y. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054481 · Cited by 5,886
Wong, W. L., Su, X., Li, X., Cheung, C. M. G., Klein, R., Cheng, C.-Y., & Wong, T. Y. (2014) · The Lancet Global Health · doi:10.1016/s2214-109x(13)70145-1 · Cited by 5,331
Global estimates of visual impairment: 2010
Pascolini, D., & Mariotti, S. P. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-300539 · Cited by 3,763
Ranibizumab versus Verteporfin for Neovascular Age-Related Macular Degeneration
Brown, D. M., Kaiser, P. K., Michels, M., Soubrane, G., Heier, J. S., Kim, R. Y., Sy, J. P., & Schneider, S. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa062655 · Cited by 3,522 · cited 1×
“The aim of this metaanalysis was to assess whether the impressive outcomes demonstrated from Phase 3 clinical trials translate to real-world clinical practice.(5) We paid particular attention to how visual acuity (VA) outcomes vary according to different treatment regimens across the world.”
BackgroundImputing missing standard deviations in meta-analyses can provide accurate results
Furukawa, T. A., Barbui, C., Cipriani, A., Brambilla, P., & Watanabe, N. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.06.006 · Cited by 1,568 · cited 1×
“When studies did not report the standard deviation, these values were imputed via multiple imputations and model results pooled.(9,10) The ratio of injections to visits was calculated when these data were available.”
MethodSeven-Year Outcomes in Ranibizumab-Treated Patients in ANCHOR, MARINA, and HORIZON
Rofagha, S., Bhisitkul, R. B., Boyer, D. S., Sadda, S. R., & Zhang, K. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.03.046 · Cited by 1,023
Cited by
Dugel, P. U., Koh, A., Ogura, Y., Jaffe, G. J., Schmidt-Erfurth, U., Brown, D. M., Gomes, A. V., Warburton, J., Weichselberger, A., & Holz, F. G. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.04.017 · Cited by 931
Mehta, H., Tufail, A., Daien, V., Lee, A. Y., Nguyen, V., Ozturk, M., Barthelmes, D., & Gillies, M. C. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.12.002 · Cited by 265
Self-citationOkada, M., Mitchell, P., Finger, R. P., Eldem, B., Talks, S. J., Hirst, C., Paladini, L., Barratt, J., Wong, T. Y., & Loewenstein, A. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.07.060 · Cited by 214
Monés, J., Singh, R. P., Bandello, F., Souied, E., Liu, X., & Gale, R. (2020) · Ophthalmologica · doi:10.1159/000502747 · Cited by 110
Mitchell, P., Holz, F. G., Hykin, P., Midena, E., Souied, E., Allmeier, H., Lambrou, G., Schmelter, T., Wolf, S., & on behalf of the ARIES study investigators (2021) · Retina · doi:10.1097/iae.0000000000003128 · Cited by 101
Khanani, A. M., Skelly, A., Bezlyak, V., Griner, R., Torres, L. R., & Sagkriotis, A. (2020) · Ophthalmology Retina · doi:10.1016/j.oret.2019.09.009 · Cited by 96
Korobelnik, J.-F., Delcourt, C., Creuzot-Garcher, C., Melaine, A., Chassetuillier, J., Lejeune, A., Bénard, S., & Dupont-Benjamin, L. (2021) · Journal of Medical Economics · doi:10.1080/13696998.2021.1971416 · Cited by 9
Metadata
- Authors
- Kim, L. N., Mehta, H., Barthelmes, D., Nguyen, V., & Gillies, M. C.
- Venue
- Retina
- Published
- 2016-08
- Volume
- 36
- Issue
- 8
- Pages
- 1418-1431
- ISSN
- 0275-004X (ISSN-L)
- OpenAlex
- W2462291236
- Cited by
- 184
- References
- 58
- FWCI
- 12.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.