Nanovitreoretinal Subretinal Gateway Device to Displace Submacular Hemorrhage: Access to the Subretinal Space Without Vitrectomy
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Wood, Edward H. MD; Rao, Prethy MD, MPH; Mahmoud, Tamer H. MD, PhDEditor(s): Williams, George A. Author Information
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“An approach that may not require PVD induction and vitrectomy involves a specially designed injection needle called the NANO SubRet Gateway Device (Vortex Surgical, MO, USA) (Wood et al., 2022).”
From Gene Therapy-Associated Uveitis (GTAU): Understanding and mitigating the adverse immune response in retinal gene therapy (2025) · cites this paper as Wood et al., 2022
In the citing paper
“Proof-of-concept studies have been conducted in pig models with no observed post-operative intraocular inflammation, pressure changes or structural retinal damage following subretinal injection of a plasmid DNA vector.”
From Gene Therapy-Associated Uveitis (GTAU): Understanding and mitigating the adverse immune response in retinal gene therapy (2025) · cites this paper as Wood et al., 2022
Citations
Cites
NATURAL HISTORY OF SUBFOVEAL SUBRETINAL HEMORRHAGE IN AGERELATED MACULAR DEGENERATION
AVERY, R. L., FEKRAT, S., HAWKINS, B. S., & BRESSLER, N. M. (1996) · Retina · doi:10.1097/00006982-199616030-00001 · Cited by 334
Haupert, C. L., McCuen, B. W., Jaffe, G. J., Steuer, E. R., Cox, T. A., Toth, C. A., Fekrat, S., & Postel, E. A. (2001) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(00)00734-0 · Cited by 233
Vitreous Surgery for Hemorrhagic and Fibrous Complications of Age-Related Macular Degeneration
Juan, E. D., & Machemer, R. (1988) · American Journal of Ophthalmology · doi:10.1016/0002-9394(88)90116-x · Cited by 223
Chang, W., Garg, S. J., Maturi, R. K., Hsu, J., Sivalingam, A., Gupta, S. A., Regillo, C. D., & Ho, A. C. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.02.007 · Cited by 121
Retinal gene therapy: surgical vector delivery in the translation to clinical trials
Ochakovski, G. A., Bartz-Schmidt, K. U., & Fischer, M. D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00174 · Cited by 110
Subretinal Pneumatic Displacement of Subretinal Hemorrhage
Martel, J. N., & Mahmoud, T. H. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.5464 · Cited by 69
Self-citationPneumatic Displacement of Submacular Hemorrhage with Subretinal Air and Tissue Plasminogen Activator
Sharma, S. K., Kumar, J. B., Kim, J. E., Thordsen, J. E., Dayani, P. N., Ober, M. D., & Mahmoud, T. H. (2017) · Ophthalmology Retina · doi:10.1016/j.oret.2017.07.012 · Cited by 66
Self-citationJung, J. J., Hoang, Q. V., Arain, M. Z. Y., & Chang, S. (2015) · Acta Ophthalmologica · doi:10.1111/aos.12840 · Cited by 11
Cited by
Melo, G. B., Cruz, N. F. S. D., Emerson, G. G., Rezende, F. A., Meyer, C. H., Uchiyama, S., Carpenter, J., Shiroma, H. F., Farah, M. E., Maia, M., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100862 · Cited by 114
Subretinal injection techniques for retinal disease: A review
Irigoyen, C., Amenabar Alonso, A., Sanchez-Molina, J., Rodríguez-Hidalgo, M., Lara-López, A., & Ruiz-Ederra, J. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11164717 · Cited by 106
Biomechanical considerations for optimising subretinal injections
L’Abbate, D., Prescott, K., Geraghty, B., Kearns, V., & STEEL, D. H. (2024) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2024.05.004 · Cited by 32
Chew, G. W. M., Ivanova, T., Patton, N., Dhawahir-Scala, F., Jasani, K., Turner, G. S., Charles, S., & Jalil, A. (2021) · Retina · doi:10.1097/iae.0000000000003294 · Cited by 30
Purdy, R., John, M., Bray, A., Clare, A. J., Copland, D. A., Chan, Y. K., Henderson, R. H., Nerinckx, F., Leroy, B. P., Yang, P., et al. (2025) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2025.101354 · Cited by 24
Metadata
- Authors
- Wood, E. H., Rao, P., & Mahmoud, T. H.
- Affiliations
- Associated Retinal Consultants (US)
- Emory University (US)
- Corresponding author
- Wood, Edward H.
- Mahmoud, Tamer H.
- Venue
- Retina
- Published
- 2019-10-30
- Volume
- 42
- Issue
- 11
- Pages
- 2225-2228
- ISSN
- 0275-004X (ISSN-L)
- OpenAlex
- W2985996583
- Cited by
- 14
- References
- 8
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 3
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Retina (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Ophthalmology › Retinal and Macular Surgery
- Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
- Health Sciences › Medicine › Ophthalmology › Ocular Diseases and Behçet’s Syndrome
- Keywords
- subretinal hemorrhage, submacular hemorrhage, retinal detachment prevention
- MeSH terms
- Fibrinolytic Agents, Humans, Tissue Plasminogen Activator, Retinal Hemorrhage, Retrospective Studies, Vitrectomy, Endotamponade
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanovitreoretinal Subretinal Gateway Device to Displace Submacular Hemorrhage: Access to the Subretinal Space Without Vitrectomy. https://app.cochat.ai/papers/10.1097/iae.0000000000002669
- The paper
- Wood, E. H., Rao, P., & Mahmoud, T. H. (2022). Nanovitreoretinal Subretinal Gateway Device to Displace Submacular Hemorrhage: Access to the Subretinal Space Without Vitrectomy. Retina. https://doi.org/10.1097/iae.0000000000002669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.