AGREEMENT BETWEEN CLINICIAN AND READING CENTER GRADINGS OF DIABETIC RETINOPATHY SEVERITY LEVEL AT BASELINE IN A PHASE 2 STUDY OF INTRAVITREAL BEVACIZUMAB FOR DIABETIC MACULAR EDEMA
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: To demonstrate a method for creating individualized laser exposure patterns for verteporfin photodynamic therapy (PDT) for peripapillary, juxtafoveal, and irregularly shaped lesions. METHODS: Laser beams from commercially available PDT lasers (Lumenis Opal [Lumenis, Inc., Yokneam, Israel (formerly Coherent Medical Group, Palo Alto, CA)] and Zeiss Visulas 690s [Carl Zeiss Jena GmbH, Jena, Germany] were masked using different patterns and household materials. The masking was tested for percentage of light transmission, fluence rate across the masked treatment area, and intensity drop-off at the edge of the mask. RESULTS: Of the materials tested, electrical tape was completely opaque, black card stock allowed 0.6% measured transmission, and yellow paper allowed 18% transmission of laser light. For the Lumenis Opal laser, the ratio of mask size to image size at the slit-lamp focal plane was 1:1. For the Zeiss Visulas laser, the ratio was 2:1; however, the exact ratio of the mask size to the image size was dependent on the spot size setting used. Unmasked areas of laser light had the expected fluence rate (i.e., no masking effect). The intensity drop-off at the mask edge was equivalent to the edge of the unmasked beam. CONCLUSION: Masks that individualize laser exposure patterns during PDT would allow safe treatment of irregular lesions and limit exposure of healthy tissue to risks of treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
Krause, J., Gulshan, V., Rahimy, E., Karth, P., Widner, K., Corrado, G. S., Peng, L., & Webster, D. R. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2018.01.034 · Cited by 564
Son, J., Shin, J. Y., Kim, H. D., Jung, K.-H., Park, K. H., & Park, S. J. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.05.029 · Cited by 235
Abràmoff, M. D., Tobey, D., & Char, D. S. (2020) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2020.02.022 · Cited by 140
“It is obviously of great importance that surrogate outcomes are stable over time as well as consistent, as multiple studies have shown for our example.(33,46) Such surrogate outcomes are fundamentally different from clinicians’ agreement with the AI or even each other: rarely has the diagnostic performance of such ind…”
ResultRemote Tool-Based Adjudication for Grading Diabetic Retinopathy
Schaekermann, M., Hammel, N., Terry, M., Ali, T. K., Liu, Y., Basham, B., Campana, B., Chen, W., Ji, X., Krause, J., et al. (2019) · Translational Vision Science & Technology · doi:10.1167/tvst.8.6.40 · Cited by 19
Metadata
- Authors
- SCOTT, I. U., BRESSLER, N. M., BRESSLER, S. B., BROWNING, D. J., CHAN, C. K., DANIS, R. P., DAVIS, M. D., KOLLMAN, C., & QIN, H.
- Venue
- Retina
- Published
- 2008-01
- Volume
- 28
- Issue
- 1
- Pages
- 36-40
- ISSN
- 0275-004X (ISSN-L)
- OpenAlex
- W1505156782
- Cited by
- 38
- References
- 0
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AGREEMENT BETWEEN CLINICIAN AND READING CENTER GRADINGS OF DIABETIC RETINOPATHY SEVERITY LEVEL AT BASELINE IN A PHASE 2 STUDY OF INTRAVITREAL BEVACIZUMAB FOR DIABETIC MACULAR EDEMA. https://app.cochat.ai/papers/10.1097/iae.0b013e31815e9385
- The paper
- SCOTT, I. U., BRESSLER, N. M., BRESSLER, S. B., BROWNING, D. J., CHAN, C. K., DANIS, R. P., DAVIS, M. D., KOLLMAN, C., & QIN, H. (2008). AGREEMENT BETWEEN CLINICIAN AND READING CENTER GRADINGS OF DIABETIC RETINOPATHY SEVERITY LEVEL AT BASELINE IN A PHASE 2 STUDY OF INTRAVITREAL BEVACIZUMAB FOR DIABETIC MACULAR EDEMA. Retina. https://doi.org/10.1097/iae.0b013e31815e9385
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.