Cited by 64Corneal surgery and disordersAdvanced Fluorescence Microscopy TechniquesOptical Coherence Tomography Applications

Evaluating Corneal Collagen Organization Using High-Resolution Nonlinear Optical Macroscopy

Open access
Jester, James V., Winkler, Moritz, Jester, Bryan E., Nien, Chyong, Chai, Dongyul, Brown, Donald J.·2010·Eye & Contact Lens: Science & Clinical Practice

Abstract

PURPOSE: Recent developments in nonlinear optical (NLO) imaging using femtosecond lasers provides a noninvasive method for detecting collagen fibers by imaging second harmonic-generated (SHG) signals. However, this technique is limited by the small field of view necessary to generate SHG signals. The purpose of this report is to review our efforts to greatly extend the field of view to assess the entire collagen structure using high-resolution macroscopic (HRMac) imaging. METHODS: Intact human eyes were fixed under pressure, and the whole cornea (13-mm diameter) was excised and embedded in low-melting point agar for vibratome sectioning (200-300 microm). Sections were then optically scanned using a Zeiss LSM 510 Meta and Chameleon femtosecond laser (Carl Zeiss Microimaging Inc., Thornwood, NY) to generate SHG images. For each vibratome section, an overlapping series of three-dimensional data sets (466 x 466 x 150 microm) were taken, covering the entire tissue (15 mm x 6 mm area) using a motorized, mechanical stage. The three-dimensional data sets were then concatenated to generate an NLO-based tomograph. RESULTS: The HRMac of the cornea yielded large macroscopic (80 megapixels per plane), three-dimensional tomographs with high resolution (0.81 microm lateral, 2.0 microm axial) in which individual collagen fibers (stromal lamellae) could be traced, segmented, and extracted. Three-dimensional reconstructions suggested that the anterior cornea comprises highly intertwined lamellae that insert into the anterior limiting lamina (Bowman's layer). CONCLUSIONS: We conclude that HRMac using NLO-based tomography provides a powerful new tool to assess collagen structural organization within the cornea.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/icl.0b013e3181ee8992

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In human corneas, the lamellar organisation through the full thickness from limbus-to-limbus has been reconstructed, demonstrating interweaving of anterior lamellae and their bow spring-like insertions in and out of Bowman's layer.

    “Also in human corneas, Jester et al. (2010) were able to reconstruct the lamellar organisation through the full thickness of the cornea from limbus-to-limbus. The reconstructions demonstrated the interweaving of the anterior lamellae and their bow spring-like insertions in and out of Bowman's layer (Fig. 1d).”

    From Corneal structure and transparency (2015) · cites this paper as Jester et al., 2010

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 18

  1. [1]Komai Y Ushiki T The three-dimensional organization of collagen fibrils in the human cornea and sclera Invest Ophthalmol Vis Sci Jul 1991 32 8 2244 2258 2071337
  2. [2]Maurice DM The structure and transparency of the cornea J Physiol 1957 136 263 286 13429485 PMC1358888
  3. [3]Meek KM Boote C The organization of collagen in the corneal stroma Exp Eye Res Mar 2004 78 3 503 512 15106929
  4. [4]Meek KM Quantock AJ The use of X-ray scattering techniques to determine corneal ultrastructure Prog Retin Eye Res Jan 2001 20 1 95 137 11070369
  5. [5]Meek KM Tuft SJ Huang Y Changes in collagen orientation and distribution in keratoconus corneas Invest Ophthalmol Vis Sci Jun 2005 46 6 1948 1956 15914608
  6. [7]Boote C Dennis S Huang Y Quantock AJ Meek KM Lamellar orientation in human cornea in relation to mechanical properties J Struct Biol Jan 2005 149 1 1 6 15629652
  7. [8]Zoumi A Yeh A Tromberg BJ Imaging cells and extracellular matrix in vivo by using second-harmonic generation and two-photon excited fluorescence Proc Natl Acad Sci U S A Aug 20 2002 99 17 11014 11019 12177437 PMC123202
  8. [10]Hochheimer BF Second harmonic light generation in the rabbit cornea Appl Opt 1982 1516 1518 20389884
  9. [11]Stoller P Kim BM Rubenchik AM Reiser KM Da Silva LB Polarization-dependent optical second-harmonic imaging of a rat-tail tendon J Biomed Opt Apr 2002 7 2 205 214 11966305
  10. [12]Yeh AT Nassif N Zoumi A Tromberg BJ Selective corneal imaging using combined second-harmonic generation and two-photon excited fluorescence Opt Lett Dec 2 2002 27 23 2082 2084 18033448
  11. [13]Morishige N Petroll WM Nishida T Kenney MC Jester JV Noninvasive corneal stromal collagen imaging using two-photon-generated second-harmonic signals J Cataract Refract Surg Nov 2006 32 11 1784 1791 17081858 PMC1855208
  12. [14]Morishige N Wahlert AJ Kenney MC Second-harmonic imaging microscopy of normal human and keratoconus cornea Invest Ophthalmol Vis Sci Mar 2007 48 3 1087 1094 17325150 PMC1894888
  13. [15]Goldman JN Benedek GB The relationship between morphology and transparency in the nonswelling corneal stroma of the shark Invest Ophthalmol Vis Sci 1967 6 574 600 6073962
  14. [17]Radner W Mallinger R Interlacing of collagen lamellae in the midstroma of the human cornea Cornea Aug 2002 21 6 598 601 12131038
  15. [18]Radner W Zehetmayer M Aufreiter R Mallinger R Interlacing and cross-angle distribution of collagen lamellae in the human cornea Cornea Sep 1998 17 5 537 543 9756449
  16. [19]Bron AJ The architecture of the corneal stroma Br J Ophthalmol Apr 2001 85 4 379 381 11264120 PMC1723930
  17. [20]Muller LJ Pels E Vrensen GF The specific architecture of the anterior stroma accounts for maintenance of corneal curvature Br J Ophthalmol Apr 2001 85 4 437 443 11264134 PMC1723934
  18. [21]Winkler M Jester B Nien-Shy C High resolution three-dimensional reconstruction of the collagenous matrix of the human optic nerve head Brain Res Bull Feb 15 81 2–3 339 348 19524027 PMC2814993

Cited by

Sorted by citations

Authors
Jester, J. V., Winkler, M., Jester, B. E., Nien, C., Chai, D., & Brown, D. J.
Affiliations
University of California, Irvine Medical Center (US)
Corresponding author
  • Jester, James V.
  • Jester, Bryan E.
Venue
Eye & Contact Lens: Science & Clinical Practice
Published
2010-09
Volume
36
Issue
5
Pages
260-264
ISSN
  • 0733-8902 (ISSN-L)
  • 1542-2321
OpenAlex
W2074781029
Cited by
64
References
1
Citations by year
2026: 3 · 2025: 3 · 2024: 5 · 2023: 6 · 2022: 2 · 2021: 2 · 2020: 4 · 2019: 1 · 2018: 7 · 2017: 5 · 2016: 3 · 2015: 6 · 2014: 1 · 2013: 6 · 2012: 3
FWCI
3.99
Type
journal article
Language
en
Open access
Locations
  • Eye & Contact Lens Science & Clinical Practice (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Eye Institute (R01EY007348, EY018665, EY016663, EY07348, R24EY016663, R01EY018665)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
Keywords
second harmonic generation, corneal stroma, 3D tomography, Bowman's layer
MeSH terms
Collagen, Cornea, Humans, Image Processing, Computer-Assisted, Lasers, Imaging, Three-Dimensional, Tomography, Optical

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review