CoChat

Boston Keratoprosthesis Outcomes and Complications

Chew, Hall F, Ayres, Brandon D, Hammersmith, Kristin M, Rapuano, Christopher J, Laibson, Peter R, Myers, Jonathan S, Jin, Ya-Ping, Cohen, Elisabeth J · 2009 · Cornea
Cited by 273

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the outcomes of the Boston Keratoprosthesis (KPro) at our institution. METHODS: A computerized database retrospectively identified all patients who received a Boston KPro from August 2005 to October 2007. RESULTS: There were 37 patients, 24 (65%) were male. Mean age was 66.3 years (median 69 years, range: 24-93 years; SD = 18.1 years). Mean follow-up was 16 months (range: 6-28 months; SD = 6.0 months). There were 36 type 1 (97%) and 1 type 2 (3%) KPros. The primary indication was failed penetrating keratoplasty in 29 patients (78%)-22 (59%) from multiple failures. Preoperative comorbidities included glaucoma [27 patients (73%)] and limbal stem cell deficiency [13 patients (35%)]. No intraoperative complications occurred. Postoperative complications included retroprosthetic membrane [24 patients (65%)], increased intraocular pressure [14 patients (38%)], glaucoma progression [5 patients (13.5%)], and endophthalmitis [4 patients (11%)-3 who discontinued prophylactic antibiotics secondary to compliance]. Thirty-six KPros (97%) were retained-1 type 2 KPro (3%) in a patient with ocular cicatricial pemphigoid extruded and was replaced. Mean best-corrected visual acuities were counting fingers preoperatively (range: light perception to 20/100) and 20/90 at last follow-up (range: light perception to 20/25). At last follow-up, 31 patients (84%) improved 2 lines or greater-3 patients (8%) had worse vision. CONCLUSIONS: Retention rates were excellent, and best-corrected visual acuities improved in the vast majority of patients. Complications can occur and require frequent follow-up to monitor and treat glaucoma progression, endophthalmitis, and inflammation. Patient compliance is of paramount importance. Despite the potential complications, the Boston KPro provides visual improvement in patients with an otherwise poor prognosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ico.0b013e3181a186dc

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Chew, H. F., Ayres, B. D., Hammersmith, K. M., Rapuano, C. J., Laibson, P. R., Myers, J. S., Jin, Y.-P., & Cohen, E. J.
Venue
Cornea
Published
2009-10
Volume
28
Issue
9
Pages
989-996
ISSN
0277-3740 (ISSN-L)
OpenAlex
W1996920186
Cited by
273
References
6
FWCI
13.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.