The DOI matches its Crossref record.
Tear Film Osmolarity Measurements in Dry Eye Disease Using Electrical Impedance Technology
Abstract
PURPOSE: Tear film hyperosmolarity is recognized as an important pathogenetic factor in dry eye syndrome, but difficulties in its measurement have limited its utility in the recent past. This prospective, nonrandomized, clinical single-center study investigates the osmolarity in tear samples of patients with keratoconjunctivitis sicca compared with healthy controls. METHODS: One hundred thirty-three patients [aged 58 years (51-64 years), 86 women and 47 men] with moderate to severe keratoconjunctivitis sicca and 95 controls [aged 52 years (48-61 years), 55 women and 40 men] were enrolled in the trial. Tear samples were collected directly from the inferior lateral tear meniscus. Inclusion criteria were a tear breakup time of less than 5 seconds, a Schirmer test with anesthesia less than 5 mm, and positive symptoms (Ocular Surface Disease Index score > 83). Tear film osmolarity was analyzed by the TearLab osmometer. RESULTS: In our study, patients with moderate to severe keratoconjunctivitis sicca showed a tear film osmolarity of 320 mOsmol/L (301-324 mOsmol/L). The results of the control group were 301 mOsmol/L (298-304 mOsmol/L). Our results revealed a significantly higher tear film osmolarity in patients with moderate to severe keratoconjunctivitis sicca compared with the control group. The sensitivity was 87%, and the specificity was 81%. CONCLUSIONS: Our results approved the referent value in moderate to severe dry eye of approximately 316 mOsmol/L, as described in the literature. The results showed a significantly higher tear film osmolarity in patients with severe keratoconjunctivitis sicca compared with the healthy controls. Testing tear film osmolarity can be a very effective objective diagnostic tool in the diagnosis of dry eye disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
TFOS DEWS II Diagnostic Methodology report
Wolffsohn, J. S., Arita, R., Chalmers, R., Djalilian, A., Dogru, M., Dumbleton, K., Gupta, P. K., Karpecki, P., Lazreg, S., Pult, H., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.001 · Cited by 2,122
Willcox, M. D. P., Argüeso, P., Georgiev, G. A., Holopainen, J. M., Laurie, G. W., Millar, T. J., Papas, E. B., Rolland, J. P., Schmidt, T. A., Stahl, U., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.03.006 · Cited by 995
Baudouin, C., Aragona, P., Messmer, E. M., Tomlinson, A., Calonge, M., Boboridis, K. G., Akova, Y. A., Geerling, G., Labetoulle, M., & Rolando, M. (2013) · The Ocular Surface · doi:10.1016/j.jtos.2013.07.003 · Cited by 509
McDonald, M., Patel, D. A., Keith, M. S., & Snedecor, S. J. (2016) · The Ocular Surface · doi:10.1016/j.jtos.2015.11.002 · Cited by 324
Rethinking Dry Eye Disease: A Perspective on Clinical Implications
Bron, A. J., Tomlinson, A., Foulks, G. N., Pepose, J. S., Baudouin, C., Geerling, G., Nichols, K. K., & Lemp, M. A. (2014) · The Ocular Surface · doi:10.1016/j.jtos.2014.02.002 · Cited by 256
Metadata
- Authors
- Jacobi, C., Jacobi, A., Kruse, F. E., & Cursiefen, C.
- Venue
- Cornea
- Published
- 2011-12
- Volume
- 30
- Issue
- 12
- Pages
- 1289-1292
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W2313218552
- Cited by
- 164
- References
- 0
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tear Film Osmolarity Measurements in Dry Eye Disease Using Electrical Impedance Technology. https://app.cochat.ai/papers/10.1097/ico.0b013e31821de383
- The paper
- Jacobi, C., Jacobi, A., Kruse, F. E., & Cursiefen, C. (2011). Tear Film Osmolarity Measurements in Dry Eye Disease Using Electrical Impedance Technology. Cornea. https://doi.org/10.1097/ico.0b013e31821de383
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.