Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 202

The DOI matches its Crossref record.

Clinical Utility of Objective Tests for Dry Eye Disease: Variability Over Time and Implications for Clinical Trials and Disease Management

Sullivan, Benjamin D., Crews, Leslie A., Sönmez, Barş, de la Paz, Maria F., Comert, Ebru, Charoenrook, Victor, de Araujo, Aline L., Pepose, Jay S., Berg, Michael S., Kosheleff, Valerie P., Lemp, Michael A. · 2012 · Cornea

Abstract

PURPOSE: To evaluate the efficacy of commonly used biomarkers in dry eye disease management in a longitudinal observational case series study followed by an interventional study in a subset of subjects treated with cyclosporine A (0.05%). METHODS: Bilateral tear osmolarity, Schirmer, tear film breakup time (TBUT), staining, meibomian grading, and Ocular Surface Disease Index were measured for a period of 3 consecutive months in participants recruited from a clinic-based population at 2 study sites. Fifty-two subjects completed the study (n = 16 mild/moderate, n = 36 severe; age, 47.1 ± 16.1 years). After the 3-month observation period, severe dry eye patients were prescribed topical cyclosporine A and evaluated for an additional 3 months. RESULTS: Tear osmolarity (8.7 ± 6.3%) exhibited significantly less variability over a 3-month period than corneal staining (12.2 ± 8.8%, P = 0.040), conjunctival staining (14.8 ± 8.9%, P = 0.002), and meibomian grading (14.3 ± 8.8%, P < 0.0001) across the entire patient population. Osmolarity also demonstrated less variation than TBUT (11.7 ± 9.0%, P = 0.059), Schirmer tests (10.7 ± 9.2%, P = 0.67), and Ocular Surface Disease Index (9.3 ± 7.8%, P = 0.94), although the differences were not significant. Variation in osmolarity was less for mild dry eye patients (5.9 ± 3.1%) than severe dry eye patients (10.0 ± 6.9%, P = 0.038). After treatment, average osmolarity and variability were lowered from 341 ± 18 mOsm/L to 307 ± 8 mOsm/L (P < 0.0001, n = 10). A downward trend in symptoms followed changes in osmolarity, declining from 44 ± 17 mOsm/L to 38 ± 18 mOsm/L (P = 0.35). None of the other signs demonstrated a change after treatment. CONCLUSIONS: Over a 3-month period, tear film osmolarity was found to have the lowest variability among commonly used signs of dry eye disease. Reductions in osmolarity preceded changes in symptoms during therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ico.0b013e318242fd60

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 202

Metadata

Authors
Sullivan, B. D., Crews, L. A., Sönmez, B., de la Paz, M. F., Comert, E., Charoenrook, V., de Araujo, A. L., Pepose, J. S., Berg, M. S., Kosheleff, V. P., & Lemp, M. A.
Venue
Cornea
Published
2012-09
Volume
31
Issue
9
Pages
1000-1008
ISSN
0277-3740 (ISSN-L)
OpenAlex
W1987200266
Cited by
202
References
0
FWCI
21.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical Utility of Objective Tests for Dry Eye Disease: Variability Over Time and Implications for Clinical Trials and Disease Management. https://app.cochat.ai/papers/10.1097/ico.0b013e318242fd60
The paper
Sullivan, B. D., Crews, L. A., Sönmez, B., de la Paz, M. F., Comert, E., Charoenrook, V., de Araujo, A. L., Pepose, J. S., Berg, M. S., Kosheleff, V. P., & Lemp, M. A. (2012). Clinical Utility of Objective Tests for Dry Eye Disease: Variability Over Time and Implications for Clinical Trials and Disease Management. Cornea. https://doi.org/10.1097/ico.0b013e318242fd60

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.