CoChat

Self-Assembling Colloidal System for the Ocular Administration of Cyclosporine A

Luschmann, Christoph, Tessmar, Joerg, Schoeberl, Simon, Strau, Olaf, Luschmann, Karl, Goepferich, Achim · 2014 · Cornea
Cited by 31

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: In this study, we developed a self-assembling micellar system to deliver cyclosporine A (CsA) in an aqueous solution to the cornea. METHODS: Two nonionic surfactants of the poly(ethylene glycol)-fatty alcohol ether type (Sympatens AS and Sympatens ACS) were characterized in terms of micelle size, shape, and charge, and their encapsulation efficiency for CsA. In an in situ single dose bioavailability study, the corneal CsA levels were determined in an enucleated porcine eye model. A commercial formulation and a 2% CsA olive oil solution served as references. RESULTS: Both surfactants formed spherical micelles with a size of 9 to 12 nm in water. A concentration as low as 0.3% (wt/vol) Sympatens AS was sufficient to entrap therapeutic levels of at least 0.1% (wt/vol) CsA. In the porcine in situ model, exceptionally high drug levels in the cornea were obtained for the micellar CsA solution (1557 ± 407 ngCsA/gcornea). They were significantly higher than those of Restasis (545 ± 137 ngCsA/gcornea) or the olive oil solution (452 ± 142 ngCsA/gcornea). CONCLUSIONS: In conclusion, we have shown a promising simple and efficient approach for the application of CsA in an aqueous solution to the cornea to treat inflammatory corneal diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ico.0b013e3182a7f3bf

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

1 retracted

Show all 3 references

Cited by

Metadata

Authors
Luschmann, C., Tessmar, J., Schoeberl, S., Strau, O., Luschmann, K., & Goepferich, A.
Venue
Cornea
Published
2014-01
Volume
33
Issue
1
Pages
77-81
ISSN
0277-3740 (ISSN-L)
OpenAlex
W2030331663
Cited by
31
References
3
FWCI
1.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.