Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 288

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Analysis of Normal Retinal Nerve Fiber Layer Thickness by Age, Sex, and Race Using Spectral Domain Optical Coherence Tomography

Alasil, Tarek, Wang, Kaidi, Keane, Pearse A., Lee, Hang, Baniasadi, Neda, de Boer, Johannes F., Chen, Teresa C. · 2013 · Journal of Glaucoma

Abstract

PURPOSE: To determine the effects of age, sex, and race on the retinal nerve fiber layer (RNFL) in the normal human eye as measured by the spectral domain optical coherence tomography (SD-OCT) Spectralis machine (Heidelberg Engineering). METHODS: Peripapillary SD-OCT RNFL thickness measurements were determined in normal subjects seen at a university-based clinic. One randomly selected eye per subject was used for analysis in this cross-sectional study. Multiple regression analysis was applied to assess the effects of age, sex, ethnicity, and mean refractive error on peripapillary RNFL thickness. Results are expressed as means±SD wherever applicable. RESULTS: The study population consisted of 190 healthy participants from 9 to 86 years of age. Of the 190 participants, 62 (33%) were men, 125 (66%) Caucasians, 26 (14%) African Americans, 14 (7%) Hispanics, 16 (8%) Asians, and 9 (5%) other races. The mean RNFL thickness for the normal population studied was 97.3 ± 9.6 µm. Normal RNFL thickness values follow the ISNT rule with decreasing RNFL thickness values starting from the thickest quadrant inferiorly to the thinnest quadrant temporally: inferior quadrant (126 ± 15.8), superior quadrant (117.2±16.13), nasal quadrant (75 ± 13.9), and temporal quadrant (70.6 ± 10.8 µm). Thinner RNFL measurements were associated with older age (P<0.001); being Caucasian, versus being either Hispanic or Asian (P=0.02 and 0.009, respectively); or being more myopic (P<0.001). For every decade of increased age, mean RNFL thickness measured thinner by approximately 1.5 µm (95% confidence interval, 0.24-0.07). Comparisons between ethnic groups revealed that Caucasians had mean RNFL values (96 ± 9.2 µm) slightly thinner than those of Hispanics (102.9 ± 11 µm; P=0.02) or Asians (100.7 ± 8.5 µm; P=0.009). African Americans RNFL values (99.2 ± 10.2 µm) were not significantly different when compared with Caucasians. There was no relationship between RNFL thickness and sex. CONCLUSIONS: The thickest RNFL measurements were found in the inferior quadrant, followed by the superior, nasal, and temporal quadrants (ISNT rule applied to the RNFL). Thinner RNFL measurements were associated with older age and increasing myopia. Caucasians tend to have thinner RNFL values when compared with Hispanics and Asians. SD-OCT analysis of the normal RNFL showed results similar to time domain OCT studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ijg.0b013e318255bb4a

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 288

Metadata

Authors
Alasil, T., Wang, K., Keane, P. A., Lee, H., Baniasadi, N., de Boer, J. F., & Chen, T. C.
Venue
Journal of Glaucoma
Published
2013-09
Volume
22
Issue
7
Pages
532-541
ISSN
1057-0829 (ISSN-L)
OpenAlex
W2314331384
Cited by
288
References
12
FWCI
12.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.