The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Analysis of Normal Retinal Nerve Fiber Layer Thickness by Age, Sex, and Race Using Spectral Domain Optical Coherence Tomography
Abstract
PURPOSE: To determine the effects of age, sex, and race on the retinal nerve fiber layer (RNFL) in the normal human eye as measured by the spectral domain optical coherence tomography (SD-OCT) Spectralis machine (Heidelberg Engineering). METHODS: Peripapillary SD-OCT RNFL thickness measurements were determined in normal subjects seen at a university-based clinic. One randomly selected eye per subject was used for analysis in this cross-sectional study. Multiple regression analysis was applied to assess the effects of age, sex, ethnicity, and mean refractive error on peripapillary RNFL thickness. Results are expressed as means±SD wherever applicable. RESULTS: The study population consisted of 190 healthy participants from 9 to 86 years of age. Of the 190 participants, 62 (33%) were men, 125 (66%) Caucasians, 26 (14%) African Americans, 14 (7%) Hispanics, 16 (8%) Asians, and 9 (5%) other races. The mean RNFL thickness for the normal population studied was 97.3 ± 9.6 µm. Normal RNFL thickness values follow the ISNT rule with decreasing RNFL thickness values starting from the thickest quadrant inferiorly to the thinnest quadrant temporally: inferior quadrant (126 ± 15.8), superior quadrant (117.2±16.13), nasal quadrant (75 ± 13.9), and temporal quadrant (70.6 ± 10.8 µm). Thinner RNFL measurements were associated with older age (P<0.001); being Caucasian, versus being either Hispanic or Asian (P=0.02 and 0.009, respectively); or being more myopic (P<0.001). For every decade of increased age, mean RNFL thickness measured thinner by approximately 1.5 µm (95% confidence interval, 0.24-0.07). Comparisons between ethnic groups revealed that Caucasians had mean RNFL values (96 ± 9.2 µm) slightly thinner than those of Hispanics (102.9 ± 11 µm; P=0.02) or Asians (100.7 ± 8.5 µm; P=0.009). African Americans RNFL values (99.2 ± 10.2 µm) were not significantly different when compared with Caucasians. There was no relationship between RNFL thickness and sex. CONCLUSIONS: The thickest RNFL measurements were found in the inferior quadrant, followed by the superior, nasal, and temporal quadrants (ISNT rule applied to the RNFL). Thinner RNFL measurements were associated with older age and increasing myopia. Caucasians tend to have thinner RNFL values when compared with Hispanics and Asians. SD-OCT analysis of the normal RNFL showed results similar to time domain OCT studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The number of people with glaucoma worldwide in 2010 and 2020
Quigley, H. A. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.081224 · Cited by 7,394
Number of people with glaucoma worldwide.
Quigley, H. A. (1996) · British Journal of Ophthalmology · doi:10.1136/bjo.80.5.389 · Cited by 2,998
Quigley, H. A. (1982) · Archives of Ophthalmology · doi:10.1001/archopht.1982.01030030137016 · Cited by 1,177
Retinal Ganglion Cell Atrophy Correlated With Automated Perimetry in Human Eyes With Glaucoma
Quigley, H. A., Dunkelberger, G. R., & Green, W. R. (1989) · American Journal of Ophthalmology · doi:10.1016/0002-9394(89)90488-1 · Cited by 1,123
A framework for comparing structural and functional measures of glaucomatous damage
Hood, D. C., & Kardon, R. H. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.08.001 · Cited by 703
Optic disc, cup and neuroretinal rim size, configuration and correlations in normal eyes.
Jonas, J. B., Gusek, G. C., & Naumann, G. O. H. (1988) · PubMed · Cited by 668
Quantitative Studies of Retinal Nerve Fiber Layer Defects
Quigley, H. A., & Addicks, E. M. (1982) · Archives of Ophthalmology · doi:10.1001/archopht.1982.01030030811018 · Cited by 304
Retinal Nerve Fiber Layer Thickness in Normal Human Eyes
Varma, R., Skaf, M., & Barron, E. (1996) · Ophthalmology · doi:10.1016/s0161-6420(96)30381-3 · Cited by 219
Wu, H., de Boer, J. F., & Chen, T. C. (2010) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3181f3eb64 · Cited by 150
Self-citationSeibold, L. K., Mandava, N., & Kahook, M. Y. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.06.024 · Cited by 114
Martinez, A., Proupim, N., & Sánchez, M. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.137471 · Cited by 108
Sehi, M., Ume, S., & Greenfield, D. S. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-1087 · Cited by 53
Cited by
Chen, J. J., Sotirchos, E. S., Henderson, A. D., Vasileiou, E. S., Flanagan, E. P., Bhatti, M. T., Jamali, S., Eggenberger, E. R., Dinome, M., Frohman, L. P., et al. (2022) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2022.103525 · Cited by 102
Metadata
- Authors
- Alasil, T., Wang, K., Keane, P. A., Lee, H., Baniasadi, N., de Boer, J. F., & Chen, T. C.
- Venue
- Journal of Glaucoma
- Published
- 2013-09
- Volume
- 22
- Issue
- 7
- Pages
- 532-541
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W2314331384
- Cited by
- 288
- References
- 12
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.