The DOI matches its Crossref record.
Cochlear Implantation in Unilateral Deaf Subjects Associated With Ipsilateral Tinnitus
Abstract
OBJECTIVE: In subjects who are deaf and who also have tinnitus in the affected ear, tinnitus treatments based on acoustic input are impossible. On the other hand, tinnitus suppression using electric stimulation has been reported to be successful. Therefore, a study was initiated to investigate the potential of cochlear implantation (CI) in unilateral deaf subjects regarding tinnitus suppression, device acceptance, and restoration of spatial hearing. METHOD: Five subjects with severe to profound unilateral deafness having also ipsilateral tinnitus were enrolled. In monthly visits, the speech processor program was optimized, and the hearing performance as well as tinnitus were monitored. In addition, it was investigated whether the CI improves hearing in adverse listening situations when combined with the normal hearing side. RESULTS: In 3 participants, the tinnitus was significantly suppressed while wearing the device. In the other 2 participants, the tinnitus could be reduced in certain situations. Speech perception tests revealed a significant benefit with the CI in combination with the normal-hearing side for 3 participants. All participants accepted the device in a clinical setting; adaptation of the frequency allocation was not required. CONCLUSION: Improvements were found regarding the hearing and the tinnitus. Not all participants benefit from the CI to the same degree and in the same situations.The results indicate that cochlear implantation in subjects with unilateral severe to profound hearing loss and ipsilateral tinnitus may be beneficial on a case-to-case basis. Further work needs to be performed to define the appropriate indication criteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implant – State of the Art
Lenarz, T. (2017) · Laryngo-Rhino-Otologie · doi:10.1055/s-0043-101812 · Cited by 283
Self-citationMertens, G., De Bodt, M., & Van de Heyning, P. (2016) · Hearing Research · doi:10.1016/j.heares.2015.09.016 · Cited by 103
The state of the art of sound therapy for subjective tinnitus in adults
Wang, H., Tang, D., Wu, Y., Zhou, L., & Sun, S. (2020) · Therapeutic Advances in Chronic Disease · doi:10.1177/2040622320956426 · Cited by 52
Cochlear Implants as a Treatment Option for Unilateral Hearing Loss, Severe Tinnitus and Hyperacusis
Ramos Macías, A., Falcón González, J. C., Manrique, M., Morera, C., García-Ibáñez, L., Cenjor, C., Coudert-Koall, C., & Killian, M. (2015) · Audiology and Neurotology · doi:10.1159/000380750 · Cited by 46
Metadata
- Authors
- Buechner, A., Brendel, M., Lesinski-Schiedat, A., Wenzel, G., Frohne-Buechner, C., Jaeger, B., & Lenarz, T.
- Venue
- Otology & Neurotology
- Published
- 2010-12
- Volume
- 31
- Issue
- 9
- Pages
- 1381-1385
- ISSN
- 1531-7129 (ISSN-L)
- OpenAlex
- W2130548760
- Cited by
- 166
- References
- 0
- FWCI
- 5.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cochlear Implantation in Unilateral Deaf Subjects Associated With Ipsilateral Tinnitus. https://app.cochat.ai/papers/10.1097/mao.0b013e3181e3d353
- The paper
- Buechner, A., Brendel, M., Lesinski-Schiedat, A., Wenzel, G., Frohne-Buechner, C., Jaeger, B., & Lenarz, T. (2010). Cochlear Implantation in Unilateral Deaf Subjects Associated With Ipsilateral Tinnitus. Otology & Neurotology. https://doi.org/10.1097/mao.0b013e3181e3d353
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.