Assessing Computational Model Credibility Using a Risk-Based Framework: Application to Hemolysis in Centrifugal Blood Pumps
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Medical device manufacturers using computational modeling to support their device designs have traditionally been guided by internally developed modeling best practices. A lack of consensus on the evidentiary bar for model validation has hindered broader acceptance, particularly in regulatory areas. This has motivated the US Food and Drug Administration and the American Society of Mechanical Engineers (ASME), in partnership with medical device companies and software providers, to develop a structured approach for establishing the credibility of computational models for a specific use. Charged with this mission, the ASME V&V 40 Subcommittee on Verification and Validation (V&V) in Computational Modeling of Medical Devices developed a risk-informed credibility assessment framework; the main tenet of the framework is that the credibility requirements of a computational model should be commensurate with the risk associated with model use. This article provides an overview of the ASME V&V 40 standard and an example of the framework applied to a generic centrifugal blood pump, emphasizing how experimental evidence from in vitro testing can support computational modeling for device evaluation. Two different contexts of use for the same model are presented, which illustrate how model risk impacts the requirements on the V&V activities and outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The medical devices modeling community has developed frameworks and methods to assess credibility of computational models for medical devices, including the ASME V&V40 2018 Standard, FDA Guidance [2], and various supporting documents [3–7].”
From Credibility assessment of in silico clinical trials for medical devices (2024) · cites this paper as [4]
The cited source says what the claim attributes to it.
In the citing paper
“Some examples of how to map model risk to credibility goals for a specific COU has been provided in medical device applications.13, 14, 15”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Giersiepen, M., Wurzinger, L. J., Opitz, R., & Reul, H. (1990) · The International Journal of Artificial Organs · doi:10.1177/039139889001300507 · Cited by 594
The use of computational fluid dynamics in the development of ventricular assist devices
Fraser, K. H., Taskin, M. E., Griffith, B. P., & Wu, Z. J. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.10.014 · Cited by 278
Zhang, T., Taskin, M. E., Fang, H.-B., Pampori, A., Jarvik, R., Griffith, B. P., & Wu, Z. J. (2011) · Artificial Organs · doi:10.1111/j.1525-1594.2011.01243.x · Cited by 192
Morrison, T. M., Pathmanathan, P., Adwan, M., & Margerrison, E. (2018) · Frontiers in Medicine · doi:10.3389/fmed.2018.00241 · Cited by 186
Self-citationStewart, S. F. C., Paterson, E. G., Burgreen, G. W., Hariharan, P., Giarra, M., Reddy, V., Day, S. W., Manning, K. B., Deutsch, S., Berman, M. R., et al. (2012) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-012-0087-5 · Cited by 158
FDA Benchmark Medical Device Flow Models for CFD Validation
Malinauskas, R. A., Hariharan, P., Day, S. W., Herbertson, L. H., Büsen, M. R., Steinseifer, U., Aycock, K. I., Good, B. C., Deutsch, S., Manning, K. B., et al. (2017) · ASAIO Journal · doi:10.1097/mat.0000000000000499 · Cited by 153
An FDA Viewpoint on Unique Considerations for Medical-Device Clinical Trials
Faris, O., & Shuren, J. (2017) · New England Journal of Medicine · doi:10.1056/nejmra1512592 · Cited by 152
Morrison, T. M., Dreher, M. L., Nagaraja, S., Angelone, L. M., & Kainz, W. (2017) · Journal of Medical Devices · doi:10.1115/1.4035866 · Cited by 68
Self-citationApplicability Analysis of Validation Evidence for Biomedical Computational Models
Pathmanathan, P., Gray, R. A., Romero, V. J., & Morrison, T. M. (2017) · Journal of Verification Validation and Uncertainty Quantification · doi:10.1115/1.4037671 · Cited by 68
Self-citationMultilaboratory Study of Flow-Induced Hemolysis Using the FDA Benchmark Nozzle Model
Herbertson, L. H., Olia, S. E., Daly, A. R., Noatch, C. P., Smith, W. A., Kameneva, M. V., & Malinauskas, R. A. (2014) · Artificial Organs · doi:10.1111/aor.12368 · Cited by 67
Research works printed but not linked: 2
- Freeman JA, Roy CJ. Verification and Validation of RANS Turbulent Models in Commercial Flow Solvers. 50th AIAA Aerospace Sciences Meeting, January 2012. [Google Scholar]
- Morrison TM, Aycock K, Weaver JD, Craven B. A Mock Submission to Initiate a Clinical Trial in the U.S. with Modeling and Simulation, Proceedings of the 2018 VPH Institute Conference, Zaragoza, Spain, 10.6084/m9.figshare.7338923. [DOI] [Google Scholar] · doi:10.6084/m9.figshare.7338923
Cited by
Viceconti, M., Pappalardo, F., Rodriguez, B., Horner, M., Bischoff, J., & Musuamba Tshinanu, F. (2021) · Methods · doi:10.1016/j.ymeth.2020.01.011 · Cited by 361
“In addition to addressing potential gaps between input system parameters, assessing the applicability also requires careful consideration of the gap between the measured validation outputs and each QOI [21].”
BackgroundInfluentialKuemmel, C., Yang, Y., Zhang, X., Florian, J., Zhu, H., Tegenge, M., Huang, S., Wang, Y., Morrison, T., & Zineh, I. (2020) · CPT: Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.12479 · Cited by 177
“Further explanation and examples of credibility assessment are provided by Morrison et al. 14 and the ASME standard.”
MethodSelf-citationIn silico modelling of cancer nanomedicine, across scales and transport barriers
Stillman, N. R., Kovacevic, M., Balaz, I., & Hauert, S. (2020) · npj Computational Materials · doi:10.1038/s41524-020-00366-8 · Cited by 97
Chelliah, V., Lazarou, G., Bhatnagar, S., Gibbs, J. P., Nijsen, M., Ray, A., Stoll, B., Thompson, R. A., Gulati, A., Soukharev, S., et al. (2021) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1987 · Cited by 76
“This follows a framework already recommended by the US Food and Drug Administration (FDA) for the modeling of medical devices.(76) Justification of parameter values shifts focus from identifiability analysis to stating parameter ranges, where the model exhibits behaviors recognized as plausible by biology experts.”
BackgroundCredibility assessment of in silico clinical trials for medical devices
Pathmanathan, P., Aycock, K., Badal, A., Bighamian, R., Bodner, J., Craven, B. A., & Niederer, S. (2024) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1012289 · Cited by 62
Metadata
- Authors
- Morrison, T. M., Hariharan, P., Funkhouser, C. M., Afshari, P., Goodin, M., & Horner, M.
- Affiliations
- United States Food and Drug Administration (US)
- Baxter (United States) (US)
- Johnson & Johnson (United States) (US)
- SimuTech Group (United States) (US)
- ANSYS, Inc., Evanston, Illinois.
- Corresponding author
- Morrison, Tina M.
- Hariharan, Prasanna
- Venue
- ASAIO Journal
- Published
- 2019-05
- Volume
- 65
- Issue
- 4
- Pages
- 349-360
- ISSN
- 1058-2916 (ISSN-L)
- PMC
- PMC6493688
- OpenAlex
- W2940409301
- Cited by
- 68
- References
- 14
- Citations by year
- 2026: 15 · 2025: 6 · 2024: 8 · 2023: 6 · 2022: 10 · 2021: 12 · 2020: 9 · 2019: 2
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- ASAIO Journal (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Mechanical Circulatory Support Devices
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Safety Systems Engineering in Autonomy
- Health Sciences › Health Professions › Medical Laboratory Technology › Quality and Safety in Healthcare
- Keywords
- model verification and validation, centrifugal blood pump, hemolysis, medical device design, model risk, in vitro evaluation
- MeSH terms
- Computer Simulation, Equipment Design, Heart-Assist Devices, Hemolysis, Humans, United States, United States Food and Drug Administration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing Computational Model Credibility Using a Risk-Based Framework: Application to Hemolysis in Centrifugal Blood Pumps. https://app.cochat.ai/papers/10.1097/mat.0000000000000996
- The paper
- Morrison, T. M., Hariharan, P., Funkhouser, C. M., Afshari, P., Goodin, M., & Horner, M. (2019). Assessing Computational Model Credibility Using a Risk-Based Framework: Application to Hemolysis in Centrifugal Blood Pumps. ASAIO Journal. https://doi.org/10.1097/mat.0000000000000996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.