The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves
Abstract
The hemodynamics of heart valve prostheses can be reproducibly investigated in vitro within circulatory mock loops. By measuring the downstream velocity and shear stress fields the shear stresses which are clinically responsible for damage to platelets and red blood cells can be determined. The mechanisms of damage and the effects of shear stresses on blood corpuscles were investigated by Wurzinger et al. (3, 4) at the Aerodynamics Institute of the RWTH Aachen. In the present study, the above data are incorporated into a mathematical correlation, which serves as a basic model for the estimation of blood damage. This mathematical model was applied to in vitro investigations of 25 different aortic valve prostheses. The results were compared to clinical findings. In most cases agreement was good, indicating that this model may be directly applied to the clinical situation. This new method facilitates the estimation of clinically expected blood damage from in vitro measurements. It may be useful for the development and evaluation of new valve prostheses. By comparative evaluation of different valve types it also provides additional information to help the implanting surgeon select the optimum valve for his patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in artificial organs-1983
渥美, 和., Maekawa, M., & 太田, 和. (1984) · Cited by 152
Platelet and Coagulation Parameters Following Millisecond Exposure to Laminar Shear Stress
Wurzinger, L. J., Opitz, R., Blasberg, P., & Schmid-Schönbein, H. (1985) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1657744 · Cited by 120
Self-citationHorstkotte, D., & Piper, C. (2003) · Springer eBooks · doi:10.1007/978-3-662-10475-0_6 · Cited by 37
Cited by
Fraser, K. H., Zhang, T., Taskin, M. E., Griffith, B. P., & Wu, Z. J. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4007092 · Cited by 384
Morrison, T. M., Hariharan, P., Funkhouser, C. M., Afshari, P., Goodin, M., & Horner, M. (2019) · ASAIO Journal · doi:10.1097/mat.0000000000000996 · Cited by 68
Metadata
- Authors
- Giersiepen, M., Wurzinger, L. J., Opitz, R., & Reul, H.
- Venue
- The International Journal of Artificial Organs
- Publisher
- SAGE Publications
- Published
- 1990-05
- Volume
- 13
- Issue
- 5
- Pages
- 300-306
- ISSN
- 0391-3988 (ISSN-L)
- 1724-6040
- OpenAlex
- W2342166896
- Cited by
- 594
- References
- 3
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves. https://app.cochat.ai/papers/10.1177/039139889001300507
- The paper
- Giersiepen, M., Wurzinger, L. J., Opitz, R., & Reul, H. (1990). Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves. The International Journal of Artificial Organs. https://doi.org/10.1177/039139889001300507
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.