Abstract
OBJECTIVE: Masked hypertension (MH) refers to nonelevated office blood pressure (BP) with elevated out-of-office BP, but its reproducibility has not been conclusively established. We examined 1-week reproducibility of MH by home BP monitoring (HBPM) and ambulatory BP monitoring (ABPM). METHODS: We recruited 420 adults not on BP-lowering medication, with recent clinic BP between 120/80 and 149/95 mmHg. For main comparisons, participants with office average less than 140/90 mmHg were considered to have MH if awake ABPM average was 135/85 mmHg or higher; they were considered to have MH by HBPM if the average was 135/85 mmHg or higher. Percentage agreements were quantified in terms of κ. We also examined the prevalence of MH, defined as office average less than 140/90 mmHg, with a 24-h ABPM average of 130/80 mmHg or higher. We carried out sensitivity analyses using different threshold BP levels for ABPM-office pairings and HBPM-office pairings for defining MH. RESULTS: Prevalence rates of MH based on office-awake ABPM pairings were 44 and 43%, with an agreement of 71% (κ=0.40; 95% confidence interval 0.31-0.49). MH was less prevalent (15 and 17%) using HBPM-office pairings, with agreement of 82% (κ=0.30; 95% confidence interval 0.16-0.44), and more prevalent when considering the 24-h average (50 and 48%). MH was also less prevalent when more stringent diagnostic criteria were applied. Office-HBPM pairings and office-awake ABPM pairings had fair agreement on MH classification on both occasions, with κ-values of 0.36 and 0.30. CONCLUSION: MH has fair short-term reproducibility, providing further evidence that for some people, out-of-office BP is systematically higher than that measured in the office setting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of Blood Pressure in the Office: Recognizing the Problem and Proposing the Solution
Myers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., & Kaczorowski, J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.141879 · Cited by 260
STERGIOU, G., SALGAMI, E., TZAMOURANIS, D., & ROUSSIAS, L. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.01.003 · Cited by 157
Niiranen, T. J., Asayama, K., Thijs, L., Johansson, J. K., Ohkubo, T., Kikuya, M., Boggia, J., Hozawa, A., Sandoya, E., Stergiou, G. S., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00100 · Cited by 120
Ambulatory Blood Pressure for Cardiovascular Risk Stratification
Verdecchia, P., Angeli, F., & Cavallini, C. (2007) · Circulation · doi:10.1161/circulationaha.107.697086 · Cited by 59
Cited by
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.11.006 · Cited by 6,616
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000066 · Cited by 4,347
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
“The test-retest agreement for masked hypertension and white-coat hypertension on HBPM is lower because it depends on the reproducibility of both office- and HBPMdefined hypertension.(157,184)”
MethodSelf-citationWhelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000596 · Cited by 1,127
Metadata
- Authors
- Viera, A. J., Lin, F.-C., Tuttle, L. A., Olsson, E., Stankevitz, K., Girdler, S. S., Klein, J. L., & Hinderliter, A. L.
- Venue
- Blood Pressure Monitoring
- Published
- 2014-08
- Volume
- 19
- Issue
- 4
- Pages
- 208-215
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2325796971
- Cited by
- 47
- References
- 4
- FWCI
- 3.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reproducibility of masked hypertension among adults 30 years or older. https://app.cochat.ai/papers/10.1097/mbp.0000000000000054
- The paper
- Viera, A. J., Lin, F.-C., Tuttle, L. A., Olsson, E., Stankevitz, K., Girdler, S. S., Klein, J. L., & Hinderliter, A. L. (2014). Reproducibility of masked hypertension among adults 30 years or older. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0000000000000054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.