Automated office blood pressure – being alone and not location is what matters most
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Measurement of office blood pressure using a fully automated sphygmomanometer that takes multiple readings with the patient resting quietly alone has been called automated office blood pressure (AOBP). Almost all AOBP research has involved the patient resting alone in an examining room, which is often impractical in a clinical setting. The possibility that valid AOBP readings can be obtained with the patient resting quietly in a waiting room was examined. METHODS: AOBP readings using the BpTRU device recorded with the patient resting quietly in the waiting room were obtained in patients referred for ambulatory BP monitoring. The relationship between the AOBP and the awake ambulatory blood pressure (AABP) (mmHg) was examined. RESULTS: In 422 patients, the mean (±SD) AABP (139.4±13.4/80.7±10.6) was similar to the mean AOBP recorded in the waiting room (140.5±19.8/83.1±11.2), with both values being significantly lower than a single office BP (155.1±18.7/90.2±12.7) taken by a nurse. In the 178 untreated patients, the mean systolic AOBP and AABP were almost identical, with the diastolic AOBP being 1.5 mmHg higher. Bland-Altman plots for systolic BP showed a relatively consistent relationship for AOBP versus the AABP over the range of BPs recorded. The sensitivity, specificity, and accuracy for AOBP versus AABP were comparable with the values obtained with AOBP recorded previously in an examining room. CONCLUSION: AOBP readings recorded in a waiting room are comparable with the AABP, making it possible to obtain AOBP in clinical practice without the need to occupy an examining room.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Self-citationCarey, R. M., Calhoun, D. A., Bakris, G. L., Brook, R. D., Daugherty, S. L., Dennison-Himmelfarb, C. R., Egan, B. M., Flack, J. M., Gidding, S. S., Judd, E., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000084 · Cited by 1,153
Olsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939
Leung, A. A., Nerenberg, K., Daskalopoulou, S. S., McBrien, K., Zarnke, K. B., Dasgupta, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., et al. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.02.066 · Cited by 461
Lee, H.-Y., Shin, J., Kim, G.-H., Park, S., Ihm, S.-H., Kim, H. C., Kim, K.-I., Kim, J. H., Lee, J. H., Park, J.-M., et al. (2019) · Clinical Hypertension · doi:10.1186/s40885-019-0124-x · Cited by 264
Metadata
- Authors
- Armstrong, D., Matangi, M., Brouillard, D., & Myers, M. G.
- Venue
- Blood Pressure Monitoring
- Published
- 2015-08
- Volume
- 20
- Issue
- 4
- Pages
- 204-208
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2417493206
- Cited by
- 68
- References
- 0
- FWCI
- 9.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated office blood pressure – being alone and not location is what matters most. https://app.cochat.ai/papers/10.1097/mbp.0000000000000133
- The paper
- Armstrong, D., Matangi, M., Brouillard, D., & Myers, M. G. (2015). Automated office blood pressure – being alone and not location is what matters most. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0000000000000133
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.