Cited by 14Blood Pressure and Hypertension StudiesAtrial Fibrillation Management and OutcomesNon-Invasive Vital Sign Monitoring

Measurement reliability of automated oscillometric blood pressure monitor in the elderly with atrial fibrillation: a systematic review and meta-analysis

Park, Seong-Hi, Choi, Yun-Kyoung·2020·Blood Pressure Monitoring

Abstract

Objectives: This study aimed to identify whether automated oscillometric blood pressure monitor (AOBPM) is a reliable blood pressure (BP) measurement tool in geriatric patients with atrial fibrillation (AF) with high variability in BP and to evaluate whether it can be applied in practice. Methods: Electronic searches were performed in databases including MEDLINE, EMBASE, the Cochrane Library, and CINAHL by using the following keywords: ‘atrial fibrillation,’ ‘atrial flutter, ‘blood pressure monitor’, ‘sphygmomanometer.’ The QUADAS-2 was applied to assess the internal validity of selected studies. Meta-analysis was performed using RevMan 5.3 program. Design: Systematic review. Results: We identified 10 studies, including 938 geriatric patients with AF. We compared with the previously used BP measurement method (mainly office) and AOBPM, and the patients with AF were divided into the AF-AF (atrial fibrillation rhythm continued) and AF-SR groups (sinus rhythm recovered). The difference in the systolic BP was −3.0 mmHg [95% confidence interval (CI): −6.58 to 0.59] and −1.62 (95% CI: −6.08 to 2.84) mmHg in the AF-AF and AF-SR groups, respectively. The difference in the diastolic BP was 0.17 (95% CI: −2.90 to 3.25) mmHg and −0.23 (95% CI: −5.11 to 4.65) mmHg, respectively. Conclusion: This review showed that the BP difference from AOBPM compared with the auscultatory BP method was less than 5 mmHg in the elderly with AF. This difference is acceptable in clinical practice. However, AOBPM compared with invasive arterial BP in the diastolic BP was a difference of 5 mmHg or more, and so its accuracy cannot be assured.

Integrity signals

Registry

Crossref · 10.1097/mbp.0000000000000414

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Park, S.-H., & Choi, Y.-K.
Affiliations
  • Soonchunhyang University (KR)
  • Korea National Open University (KR)
Corresponding author
Choi, Yun-Kyoung
Venue
Blood Pressure Monitoring
Published
2020-02
Volume
25
Issue
1
Pages
2-12
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2987157140
Cited by
14
References
6
Citations by year
2025: 4 · 2024: 2 · 2023: 2 · 2022: 4 · 2021: 2
FWCI
0.27
Type
journal article
Language
en
Open access
closed
Locations
  • Blood Pressure Monitoring (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
atrial fibrillation, elderly patients, auscultatory blood pressure, systolic blood pressure, diastolic blood pressure, sinus rhythm restoration, blood pressure variability
MeSH terms
Aged, Atrial Fibrillation, Blood Pressure Determination, Female, Humans, Male, Oscillometry, Reproducibility of Results, Blood Pressure Monitors, Arterial Pressure

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›