Objectives To clinically evaluate an inflation-based algorithm incorporated into a new automated blood pressure monitor manufactured by Welch Allyn, Inc. Methods Device evaluation was performed according to the Association for the Advancement of Medical Instrumentation standard. An overabundance of patients with hypertension (32) were part of the 110 total participants. The data were also analyzed as described in the British Hypertension Society protocol. Results The mean error and standard deviation for systolic blood pressure were -0.9 mmHg+/-7.2; for diastolic blood pressure -2.2 mmHg+/-6.7. These passed the Association for the Advancement of Medical Instrumentation standard requirements. By British Hypertension Society data analysis, the device achieved an AA grading. Over 90% of the cycles' blood pressure values were obtained during inflation. Conclusions The SureBP inflation-based algorithm successfully passed the Association for the Advancement of Medical Instrumentation standard requirements and achieved an AA rating by British Hypertension Society data analysis. The monitor has great advantages for patient comfort and speed of readings (average 15 s per reading). As the population studied was skewed by including a much larger than needed number of patients with hypertension, clinicians can have added confidence in this new technology.

Overview

Integrity signals

Registry

Crossref · 10.1097/mbp.0b013e3280b0840d

Cites

0 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

  • American National Standard. Electronic or automated sphygmomanometers

    (2006)

    Unresolved
  • The British Hypertension Society protocol for the evaluation of blood pressure measuring devices

    O'Brien (1993) · J Hypertens

    Unresolved

Show all 2 references

Cited by

See all 15

Metadata

Authors
Alpert, B. S.
Affiliations
Welch Allyn (United States) (US)
Corresponding author
Alpert, Bruce S.
Venue
Blood Pressure Monitoring
Published
2007-08
Volume
12
Issue
4
Pages
215-218
ISSN
1359-5237 (ISSN-L)
OpenAlex
W2023838699
Cited by
15
References
2
Citations by year
2024: 3 · 2022: 2 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 3 · 2017: 1 · 2016: 1
FWCI
0.23
Type
journal article
Language
en
Open access
closed
Locations
  • Blood Pressure Monitoring (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Clinical Studies
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
automated blood pressure measurement, hypertension, measurement error, British Hypertension Society protocol, AAMI standards, cuff inflation, patient comfort
MeSH terms
Adolescent, Adult, Aged, Aged, 80 and over, Algorithms, Arm, Blood Pressure, Blood Pressure Determination, Female, United Kingdom, Humans, Hypertension, Male, Middle Aged, Blood Pressure Monitors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.