Out-of-office blood pressure monitoring in chronic kidney disease
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Blood pressure (BP) control is vital to the management of patients with chronic kidney disease (CKD) yet most treatment decisions use BPs obtained in the clinic. The purpose of this report is to review the importance of self-measured and automatic ambulatory BPs in the management of patients with CKD. Compared with clinic-obtained BPs, self-measured BP more accurately defines hypertension in CKD. Masked hypertension seems to be associated with higher risk of end-stage renal disease in CKD patients. Conversely, white-coat hypertension seems to be associated with better renal outcomes than those who have persistent hypertension. Ambulatory BP monitoring is the only tool to monitor BP during sleep, diagnose nondipping, and, as self-measured BPs, have greater prognostic power in CKD compared with clinic BP. In hemodialysis patients, self-measured BP, but not pre/post-dialysis BP, shares the combination of high sensitivity and high specificity of greater than 80% to make a diagnosis of hypertension with the reference standard of ambulatory BP monitoring. In addition, self-measured and ambulatory BPs seem to be better correlates of left-ventricular hypertrophy and mortality in hemodialysis patients compared with pre/post-dialysis BP. Emerging data suggest that out-of-office BP monitoring is superior to BP obtained in the clinic when predicting target-organ damage and prognosis. Out-of-office BP monitoring is recommended for the management of hypertension in all stages of CKD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Dolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227
Prognostic Value of Ambulatory Blood-Pressure Recordings in Patients with Treated Hypertension
Clement, D. L., De Buyzere, M. L., De Bacquer, D. A., de Leeuw, P. W., Duprez, D. A., Fagard, R. H., Gheeraert, P. J., Missault, L. H., Braun, J. J., Six, R. O., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022273 · Cited by 1,085
Kikuya, M., Ohkubo, T., Asayama, K., Metoki, H., Obara, T., Saito, S., Hashimoto, J., Totsune, K., Hoshi, H., Satoh, H., et al. (2005) · Hypertension · doi:10.1161/01.hyp.0000152079.04553.2c · Cited by 417
PIERDOMENICO, S., LAPENNA, D., BUCCI, A., DITOMMASO, R., DIMASCIO, R., MANENTE, B., CALDARELLA, M., NERI, M., CUCCURULLO, F., & MEZZETTI, A. (2005) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.05.014 · Cited by 409
Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk
Kikuya, M., Hansen, T. W., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Ibsen, H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.662254 · Cited by 314
Masked hypertension: A systematic review
Bobrie, G., Clerson, P., Ménard, J., Postel-Vinay, N., Chatellier, G., & Plouin, P.-F. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282fbcedf · Cited by 279
Home Blood Pressures Are of Greater Prognostic Value than Hemodialysis Unit Recordings
Alborzi, P., Patel, N., & Agarwal, R. (2007) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.02250507 · Cited by 248
Self-citationAgarwal, R., Peixoto, A. J., Santos, S. F. F., & Zoccali, C. (2006) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01891105 · Cited by 245
Self-citationHome blood pressure monitoring improves the diagnosis of hypertension in hemodialysis patients
Agarwal, R., Andersen, M. J., Bishu, K., & Saha, C. (2006) · Kidney International · doi:10.1038/sj.ki.5000145 · Cited by 175
Self-citation
Cited by
Blood Pressure and Mortality Among Hemodialysis Patients
Agarwal, R. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.144899 · Cited by 274
Self-citationBedtime Dosing of Antihypertensive Medications Reduces Cardiovascular Risk in CKD
Hermida, R. C., Ayala, D. E., Mojón, A., & Fernández, J. R. (2011) · Journal of the American Society of Nephrology · doi:10.1681/asn.2011040361 · Cited by 269
Akpolat, T., Erdem, E., & Aydogdu, T. (2012) · Kidney and Blood Pressure Research · doi:10.1159/000330719 · Cited by 25
Improving blood pressure control using digital communication methods in Serbia
Tasic, N., Tasic, D., Kovacevic, Z., Filipovic, M., Arsic, M., Bozovic-Ogarevic, S., Despotovic, B., Bojic, M., Maksimovic, Z., Zdravkovic, N., et al. (2022) · Diagnostics · doi:10.3390/diagnostics12040914 · Cited by 1
“Additionally, home measurement has several advantages, such as better reproducibility, better correlation to end-organ damage, and the absence of the white coat effect [10,11].”
Background
Metadata
- Authors
- Agarwal, R., Peixoto, A. J., Santos, S. F. F., & Zoccali, C.
- Venue
- Blood Pressure Monitoring
- Published
- 2009-02
- Volume
- 14
- Issue
- 1
- Pages
- 2-11
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2050351859
- Cited by
- 71
- References
- 14
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Out-of-office blood pressure monitoring in chronic kidney disease. https://app.cochat.ai/papers/10.1097/mbp.0b013e3283262f58
- The paper
- Agarwal, R., Peixoto, A. J., Santos, S. F. F., & Zoccali, C. (2009). Out-of-office blood pressure monitoring in chronic kidney disease. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0b013e3283262f58
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.