Can sphygmomanometers designed for self-measurement of blood pressure in the home be used in office practice?
The DOI matches its Crossref record.
Abstract
OBJECTIVE: To examine the possibility of measuring automated office (AO) blood pressure (BP) using home BP recorders in place of the more expensive, fully automated devices designed specifically for professional use. PARTICIPANTS AND METHODS: Three groups of 100 patients each had five AOBP readings recorded with one of three home BP devices while resting alone in a quiet examining room. These devices were also used to obtain 24 home BP readings during 6 days. Five AOBP readings were also recorded using the BpTRU device and all patients had 24-h ambulatory BP and manual BP readings taken. RESULTS: Mean systolic AOBP was within 3-4 mmHg of the mean awake ambulatory BP for each of the three home BP recorders whether used in the office setting or at home. Diastolic readings tended to be higher than the corresponding awake ambulatory BP. For the 139 patients with hypertension, mean (±standard deviation) AOBP taken with the home BP devices (146±14/86±12) was higher (P<0.001) than the awake ambulatory BP (142±11/81±12) and AOBP taken with the BpTRU device (141±15/82±12). Systolic BP at home (142±14/85±10) was also similar to the awake ambulatory BP but diastolic BP was higher (P<0.001). There were no significant differences in correlation coefficients between each set of AOBP readings and awake ambulatory BP. CONCLUSION: Home BP devices may be used to record AOBP in selected patients. However, a fully automated sphygmomanometer is still the device of choice for obtaining AOBP readings similar to the awake ambulatory BP in patients with suspected hypertension.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Self-citationMyers, M. G., Godwin, M., Dawes, M., Kiss, A., Tobe, S. W., Grant, F. C., & Kaczorowski, J. (2011) · BMJ · doi:10.1136/bmj.d286 · Cited by 285
Self-citationRoerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216
Self-citationMapesi, H., Gupta, R., Wilson, H. I., Lukau, B., Amstutz, A., Lyimo, A., Muhairwe, J., Senkoro, E., Byakuzana, T., Mphunyane, M., et al. (2021) · Trials · doi:10.1186/s13063-021-05023-z · Cited by 8
Metadata
- Authors
- Myers, M. G., Valdivieso, M., Chessman, M., & Kiss, A.
- Venue
- Blood Pressure Monitoring
- Published
- 2010-12
- Volume
- 15
- Issue
- 6
- Pages
- 300-304
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2328193219
- Cited by
- 37
- References
- 0
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Can sphygmomanometers designed for self-measurement of blood pressure in the home be used in office practice? https://app.cochat.ai/papers/10.1097/mbp.0b013e328340d128
- The paper
- Myers, M. G., Valdivieso, M., Chessman, M., & Kiss, A. (2010). Can sphygmomanometers designed for self-measurement of blood pressure in the home be used in office practice? Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0b013e328340d128
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.