Asleep home blood pressure monitoring in obstructive sleep apnea: a pilot study
The DOI matches its Crossref record.
Abstract
BACKGROUND: Obstructive sleep apnea (OSA) is known to be related to nocturnal blood pressure (BP) and nondipping hypertension. This pilot study evaluated night-time BP assessed using a home monitor in patients with OSA. PARTICIPANTS AND METHODS: Patients referred to a sleep clinic were subjected to polysomnography, clinic BP measurements, and home BP monitoring using a device that allows daytime (3 days, two duplicate readings per day) and automated night-time BP measurement (3 nights, three readings per night). RESULTS: Thirty-nine patients were included [72% men, mean age 48.7±10.8 years, clinic BP 131.2±19.6/84.1±11.9 mmHg, apnea-hypopnea index (AHI): 35.2±25.7]. All BP measurements were significantly correlated with the polysomnography indices. There was a consistent trend toward stronger correlations of the night-time diastolic home BP with the AHI (r=0.56), the duration of desaturation (0.53), and the maximum (-0.57) and minimum (-0.48) arterial oxygen saturation (all P<0.001). In stepwise multivariate analysis (independent variables age, sex, body weight, smoking status, and BP parameters), the AHI was associated independently with weight and night-time diastolic home BP (R=0.53). CONCLUSION: In patients with OSA, the assessment of night-time BP using a home monitor appears to be feasible and related to the severity of OSA. Given the wide availability of home BP monitoring in clinical practice, this method appears to be useful in the evaluation of BP in patients with OSA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Preliminary evidence suggests that nocturnal HBPM can be used as an alternative to ABPM in the investigation of nocturnal BP in patients with sleep apnoea [230,231].”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Still being checked.
Cited by
Parati, G., Stergiou, G. S., Bilo, G., Kollias, A., Pengo, M., Ochoa, J. E., Agarwal, R., Asayama, K., Asmar, R., Burnier, M., et al. (2021) · Journal of Hypertension · doi:10.1097/hjh.0000000000002922 · Cited by 178
Self-citationNocturnal blood pressure measured by home devices: evidence and perspective for clinical application
Asayama, K., Fujiwara, T., Hoshide, S., Ohkubo, T., Kario, K., Stergiou, G. S., Parati, G., White, W. B., Weber, M. A., & Imai, Y. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000001987 · Cited by 120
Self-citationKollias, A., Ntineri, A., & Stergiou, G. S. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001189 · Cited by 90
Self-citationHome blood pressure monitoring: Australian Expert Consensus Statement
Sharman, J. E., Howes, F. S., Head, G. A., McGrath, B. P., Stowasser, M., Schlaich, M., Glasziou, P., & Nelson, M. R. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000673 · Cited by 83
“It is possible to also measure night-time BP using some home BP devices, which provide night-time BP values comparable to 24-ABPM [18–21].”
Implementing Home Blood Pressure Monitoring into Clinical Practice
Liyanage-Don, N. A., Fung, D., Phillips, E., & Kronish, I. M. (2019) · Current Hypertension Reports · doi:10.1007/s11906-019-0916-0 · Cited by 65
Metadata
- Authors
- Stergiou, G. S., Triantafyllidou, E., Cholidou, K., Kollias, A., Destounis, A., Nasothimiou, E. G., Markozannes, E., & Alchanatis, M.
- Venue
- Blood Pressure Monitoring
- Published
- 2013-02
- Volume
- 18
- Issue
- 1
- Pages
- 21-26
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2000534462
- Cited by
- 15
- References
- 0
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.