Heart???lung interactions
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Assessment of cardiovascular stability using ventilation-induced changes in measured physiological variables, referred to as functional hemodynamic monitoring, usually requires measurement of ventilation-induced changes in venous return. Thus, it is important to understand the determinants of these complex heart-lung interactions. RECENT FINDINGS: Several animal and human studies have recently documented that ventricular interdependence plays an important role during positive-pressure breathing, causing acute cor pulmonale. With the use of lower tidal volume ventilation in patients with acute respiratory failure, the incidence of acute cor pulmonale is decreasing proportionally. When present, however, it induces a stroke volume variation that is 180 degrees out of phase with that seen in hypovolemic states, such that left ventricular stroke volume increases during inspiration rather than decreasing as seen in hypovolemia. Further, when either tidal volume or positive end-expiratory pressure levels are varied, both stroke volume variation and pulse pressure variation are affected in a predictable manner. The greater the swing in intrathoracic pressure, the greater the change in venous return. SUMMARY: Functional hemodynamic monitoring is becoming more prevalent. For it to be used effectively, the operator needs to have a solid understanding of how ventilation induces both pulse pressure variation and stroke volume variation in that specific patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUGA, H., & SAGAWA, K. (1974) · Circulation Research · doi:10.1161/01.res.35.1.117 · Cited by 1,330
Kaneko, Y., Floras, J. S., Usui, K., Plante, J., Tkacova, R., Kubo, T., Ando, S.-I., & Bradley, T. D. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa022479 · Cited by 1,051
Respiratory sinus arrhythmia in the denervated human heart
Bernardi, L., Keller, F., Sanders, M., Reddy, P. S., Griffith, B., Meno, F., & Pinsky, M. R. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.4.1447 · Cited by 272
Self-citationVentilatory management of acute respiratory distress syndrome: A consensus of two.
Marini, J. J., & Gattinoni, L. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000104946.66723.a8 · Cited by 168
Cited by
(2004) · New England Journal of Medicine · doi:10.1056/nejmoa032193 · Cited by 2,565
Chemical Control Stability in Patients with Obstructive Sleep Apnea
YOUNES, M., OSTROWSKI, M., THOMPSON, W., LESLIE, C., & SHEWCHUK, W. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.5.2007013 · Cited by 439
Price, L. C., Wort, S. J., Finney, S. J., Marino, P. S., & Brett, S. J. (2010) · Critical Care · doi:10.1186/cc9264 · Cited by 389
The response of the vena cava to abdominal breathing
Byeon, K., Choi, J.-O., Yang, J. H., Sung, J., Park, S. W., Oh, J. K., & Hong, K. P. (2012) · The Journal of Alternative and Complementary Medicine · doi:10.1089/acm.2010.0656 · Cited by 42
Metadata
- Authors
- Pinsky, M. R.
- Venue
- Current Opinion in Critical Care
- Published
- 2007-10
- Volume
- 13
- Issue
- 5
- Pages
- 528-531
- ISSN
- 1070-5295 (ISSN-L)
- OpenAlex
- W1989879487
- Cited by
- 109
- References
- 4
- FWCI
- 5.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart???lung interactions. https://app.cochat.ai/papers/10.1097/mcc.0b013e3282efad97
- The paper
- Pinsky, M. R. (2007). Heart???lung interactions. Current Opinion in Critical Care. https://doi.org/10.1097/mcc.0b013e3282efad97
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.