Abstract
PURPOSE OF REVIEW: Tissue hypoperfusion is a common pathophysiologic process leading to multiple-organ dysfunction and death. An important goal of hemodynamic monitoring is the early detection of inadequate tissue perfusion and oxygenation. The use of simple, noninvasive monitoring techniques has the advantage of facilitating earlier initiation of therapy. Near-infrared spectroscopy has emerged in recent years as a tool for monitoring peripheral oxygenation (StO2) in various tissues, including muscle. Here, we review our current knowledge about the applicability, usefulness, and limitations of near-infrared spectroscopy as a technique to evaluate muscle oxygenation in acutely ill patients. RECENT FINDINGS: StO2 may be an appropriate measure for early resuscitation of critically ill patients, especially in those with low cardiac output states or after severe trauma. Its usefulness in sepsis is less well established. However, by inducing an occlusion stress, a variety of dynamic variables can be measured to assess local metabolic demand and microvascular reactivity. Several recent studies have shown that profound alterations of these near-infrared-spectroscopy-derived dynamic variables are frequent in patients with severe sepsis and these alterations are associated with a poor outcome. SUMMARY: Near-infrared spectroscopy provides a noninvasive measure of muscle oxygen metabolism and microvascular dysfunction in critically ill patients. It may be useful to guide the management of critically ill patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
Cited by
Gómez, H., Mesquida, J., Simon, P., Kim, H. K., Puyana, J. C., Ince, C., & Pinsky, M. R. (2009) · Critical Care · doi:10.1186/cc8001 · Cited by 94
“Finally, since the primary reason to perform the VOT is to produce a transient ischaemic challenge to note the subsequent ReO2, the level of ischaemic challenge might vary for the same ischaemic time or threshold StO 2 . As a consequence, caution must be taken when comparing results from the available literature on th…”
ResultKayambu, G., Boots, R. J., & Paratz, J. D. (2011) · BMC Anesthesiology · doi:10.1186/1471-2253-11-21 · Cited by 37
Lee, J.-H., Park, Y.-H., Kim, H.-S., & Kim, J.-T. (2015) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-014-9595-1 · Cited by 20
Metadata
- Authors
- Creteur, J.
- Venue
- Current Opinion in Critical Care
- Published
- 2008-06
- Volume
- 14
- Issue
- 3
- Pages
- 361-366
- ISSN
- 1070-5295 (ISSN-L)
- OpenAlex
- W1978036531
- Cited by
- 100
- References
- 1
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Muscle StO2 in critically ill patients. https://app.cochat.ai/papers/10.1097/mcc.0b013e3282fad4e1
- The paper
- Creteur, J. (2008). Muscle StO2 in critically ill patients. Current Opinion in Critical Care. https://doi.org/10.1097/mcc.0b013e3282fad4e1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.