Bioelectrical impedance analysis in the assessment of sarcopenia
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Bioelectrical impedance analysis (BIA) is an accepted technique to estimate low muscle mass for sarcopenia diagnosis. However, muscularity assessment from BIA relies on prediction equations, estimating different compartments according to the calibration method. Low muscle mass can be defined using different approaches. RECENT FINDINGS: There is a lack of standardization on how low muscularity is defined in the context of sarcopenia. Recent studies have shown discrepant results for the estimation of low muscle mass when different prediction equations are used in the same BIA device. Different sarcopenia prevalence rates are observed if different definitions are used to identify low muscle mass. Most of the studies using BIA for diagnosing sarcopenia use the incorrect combination of specific population cut-off or a different device from the original equation. SUMMARY: The lack of standardization of BIA use for assessing muscularity results in a wide range of sarcopenia prevalence rates among studies, even when conducted in the same population. As BIA equations and cut-off values are population and device-specific, results should be interpreted with caution when data from different devices are applied in equations or using cut-off values from a different population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sarcopenia: European consensus on definition and diagnosis
Cruz-Jentoft, A. J., Baeyens, J. P., Bauer, J. M., Boirie, Y., Cederholm, T., Landi, F., Martin, F. C., Michel, J.-P., Rolland, Y., Schneider, S. M., et al. (2010) · Age and Ageing · doi:10.1093/ageing/afq034 · Cited by 11,601
Sarcopenia in Asia: Consensus Report of the Asian Working Group for Sarcopenia
Chen, L.-K., Liu, L.-K., Woo, J., Assantachai, P., Auyeung, T.-W., Bahyah, K. S., Chou, M.-Y., Chen, L.-Y., Hsu, P.-S., Krairit, O., et al. (2014) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2013.11.025 · Cited by 4,051
Estimation of skeletal muscle mass by bioelectrical impedance analysis
Janssen, I., Heymsfield, S. B., Baumgartner, R. N., & Ross, R. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.2.465 · Cited by 1,482
Self-citationShafiee, G., Keshtkar, A., Soltani, A., Ahadi, Z., Larijani, B., & Heshmat, R. (2017) · Journal of Diabetes & Metabolic Disorders · doi:10.1186/s40200-017-0302-x · Cited by 1,076
Pitfalls in the measurement of muscle mass: A need for a reference standard
Buckinx, F., Landi, F., Cesari, M., Fielding, R. A., Visser, M., Engelke, K., Maggi, S., Dennison, E., Al‐Daghri, N. M., Allepaerts, S., et al. (2018) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12268 · Cited by 765
Heymsfield, S. B., Gonzalez, M. C., Lu, J., Jia, G., & Zheng, J. (2015) · Proceedings of the Nutrition Society · doi:10.1017/s0029665115000129 · Cited by 483
Self-citationSergi, G., De Rui, M., Veronese, N., Bolzetta, F., Berton, L., Carraro, S., Bano, G., Coin, A., Manzato, E., & Perissinotto, E. (2015) · Clinical Nutrition · doi:10.1016/j.clnu.2014.07.010 · Cited by 467
Liu, P., Hao, Q., Hai, S., Wang, H., Cao, L., & Dong, B. (2017) · Maturitas · doi:10.1016/j.maturitas.2017.04.007 · Cited by 331
Bosy-Westphal, A., Jensen, B., Braun, W., Pourhassan, M., Gallagher, D., & Müller, M. J. (2017) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2017.27 · Cited by 231
Kim, M., Shinkai, S., Murayama, H., & Mori, S. (2015) · Geriatrics & Gerontology International · doi:10.1111/ggi.12384 · Cited by 221
Cited by
Cruz-Jentoft, A. J., & Sayer, A. A. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31138-9 · Cited by 3,905
Barazzoni, R., Jensen, G. L., Correia, M. I. T. D., Gonzalez, M. C., Higashiguchi, T., Shi, H. P., Bischoff, S. C., Boirie, Y., Carrasco, F., Cruz-Jentoft, A., et al. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.02.001 · Cited by 406
Self-citationObesity subtypes, related biomarkers & heterogeneity
Mayoral, L. P.-C., Andrade, G. M., Mayoral, E. P.-C., Huerta, T. H., Canseco, S. P., Rodal Canales, F. J., Cabrera-Fuentes, H. A., Cruz, M. M., Pérez Santiago, A. D., Alpuche, J. J., et al. (2020) · Indian Journal of Medical Research · doi:10.4103/ijmr.ijmr_1768_17 · Cited by 277
Bioelectrical impedance analysis (BIA) -derived phase angle in sarcopenia: A systematic review
Di Vincenzo, O., Marra, M., Di Gregorio, A., Pasanisi, F., & Scalfi, L. (2021) · Clinical Nutrition · doi:10.1016/j.clnu.2020.10.048 · Cited by 269
Advances in muscle health and nutrition: A toolkit for healthcare professionals
Prado, C. M., Landi, F., Chew, S. T. H., Atherton, P. J., Molinger, J., Ruck, T., & Gonzalez, M. C. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.07.041 · Cited by 237
Metadata
- Authors
- Gonzalez, M. C., Barbosa-Silva, T. G., & Heymsfield, S. B.
- Venue
- Current Opinion in Clinical Nutrition & Metabolic Care
- Published
- 2018-09
- Volume
- 21
- Issue
- 5
- Pages
- 366-374
- ISSN
- 1363-1950 (ISSN-L)
- OpenAlex
- W2810417822
- Cited by
- 146
- References
- 16
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioelectrical impedance analysis in the assessment of sarcopenia. https://app.cochat.ai/papers/10.1097/mco.0000000000000496
- The paper
- Gonzalez, M. C., Barbosa-Silva, T. G., & Heymsfield, S. B. (2018). Bioelectrical impedance analysis in the assessment of sarcopenia. Current Opinion in Clinical Nutrition & Metabolic Care. https://doi.org/10.1097/mco.0000000000000496
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.