Does Health Information Exchange Reduce Redundant Imaging? Evidence From Emergency Departments
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Broad-based electronic health information exchange (HIE), in which patients' clinical data follow them between care delivery settings, is expected to produce large quality gains and cost savings. Although these benefits are assumed to result from reducing redundant care, there is limited supporting empirical evidence. OBJECTIVE: To evaluate whether HIE adoption is associated with decreases in repeat imaging in emergency departments (EDs). DATA SOURCE/STUDY SETTING: ED discharge data from the State Emergency Department Databases for California and Florida for 2007-2010 were merged with Health Information Management Systems Society data that report hospital HIE participation. METHODS: Using regression with ED fixed effects and trends, we performed a retrospective analysis of the impact of HIE participation on repeat imaging, comparing 37 EDs that initiated HIE participation during the study period to 410 EDs that did not participate in HIE during the same period. Within 3 common types of imaging tests [computed tomography (CT), ultrasound, and chest x-ray), we defined a repeat image for a given patient as the same study in the same body region performed within 30 days at unaffiliated EDs. RESULTS: In our sample there were 20,139 repeat CTs (representing 14.7% of those cases with CT in the index visit), 13,060 repeat ultrasounds (20.7% of ultrasound cases), and 29,703 repeat chest x-rays (19.5% of x-ray cases). HIE was associated with reduced probability of repeat ED imaging in all 3 modalities: -8.7 percentage points for CT [95% confidence interval (CI): -14.7, -2.7], -9.1 percentage points for ultrasound (95% CI: -17.2, -1.1), and -13.0 percentage points for chest x-ray (95% CI: -18.3, -7.7), reflecting reductions of 44%-67% relative to sample means. CONCLUSIONS: HIE was associated with reduced repeat imaging in EDs. This study is among the first to find empirical support for this anticipated benefit of HIE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The “Meaningful Use” Regulation for Electronic Health Records
Blumenthal, D., & Tavenner, M. (2010) · New England Journal of Medicine · doi:10.1056/nejmp1006114 · Cited by 2,059
Cited by
Overtreatment in the United States
Lyu, H., Xu, T., Brotman, D., Mayer-Blackwell, B., Cooper, M., Daniel, M., Wick, E. C., Saini, V., Brownlee, S., & Makary, M. A. (2017) · PLOS ONE · doi:10.1371/journal.pone.0181970 · Cited by 341
Atasoy, H., Greenwood, B. N., & McCullough, J. S. (2019) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-040218-044206 · Cited by 256
Electronic Health Records: How Can IS Researchers Contribute to Transforming Healthcare?1
Kohli, R., & Tan, S. S.-L. (2016) · MIS Quarterly · doi:10.25300/misq/2016/40.3.02 · Cited by 212
Usage and Effect of Health Information Exchange: A Systematic Review
Rudin, R. S., Motala, A., Goldzweig, C. L., & Shekelle, P. G. (2014) · Annals of Internal Medicine · doi:10.7326/m14-0877 · Cited by 198
“In the 1 study that found an association with greater numbers of ED visits, the author interpreted the association to be potentially due to confounding by indication (for example, sicker patients were more likely to have the HIE accessed), for which the analysis could not control (23).”
BackgroundEverson, J., Kocher, K. E., & Adler-Milstein, J. (2017) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw116 · Cited by 194
Self-citation
Metadata
- Authors
- Lammers, E. J., Adler-Milstein, J., & Kocher, K. E.
- Venue
- Medical Care
- Published
- 2014-03
- Volume
- 52
- Issue
- 3
- Pages
- 227-234
- ISSN
- 0025-7079 (ISSN-L)
- OpenAlex
- W2044234555
- Cited by
- 119
- References
- 1
- FWCI
- 19.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.