Cited by 13Medical Imaging Techniques and ApplicationsLymphoma Diagnosis and TreatmentLung Cancer Diagnosis and Treatment

Quantitative assessment of 18F-FDG PET in patients with Hodgkin lymphoma: is it significantly affected by contrast-enhanced computed tomography attenuation correction?

Open access
Voltin, Conrad-Amadeus, Mettler, Jasmin, Boellaard, Ronald, Kuhnert, Georg, Dietlein, Markus, Borchmann, Peter, Drzezga, Alexander, Kobe, Carsten·2019·Nuclear Medicine Communications

Abstract

OBJECTIVE: The reliability of visual and quantitative response assessment may be impaired owing to inconsistent scanning protocols and image reconstruction methods of 2-deoxy-2-[F]fluoro-D-glucose (F-FDG) PET. Hence, this study investigates the effect of contrast-enhanced computed tomography (CT) attenuation correction in patients with Hodgkin lymphoma. PATIENTS AND METHODS: In 10 consecutive patients undergoing either staging or response assessment, F-FDG PET images were attenuation-corrected once on the basis of unenhanced CT and additionally using contrast-enhanced CT. Reconstruction was performed in both cases with ordered subset expectation maximization (OSEM) and ultra-high definition (UHD) algorithm. While maximum and peak standardized uptake value (SUV) were obtained from tumour tissue (lesionSUVmax and lesionSUVpeak), maximum and mean SUVs were determined within the background regions liver (liverSUVmax and liverSUVmean) and mediastinal blood pool (mbpSUVmax and mbpSUVmean). RESULTS: After switching to contrast-enhanced CT attenuation correction, lesionSUVmax and lesionSUVpeak increased on average by 2.55±3.24 (P=0.018) and 3.64±3.22% (P=0.008), respectively, with OSEM and by 4.59±5.49 (P=0.005) and 3.84±5.65% (P=0.005), respectively, with UHD reconstruction. LiverSUVmax and liverSUVmean showed a mean rise of 7.15±4.27 (P=0.005) and 6.97±2.18% (P=0.005), respectively, in the OSEM data sets and of 7.24±6.59 (P=0.017) and 6.29±2.83% (P=0.005), respectively, in the UHD images. The average increases of mbpSUVmax and mbpSUVmean were 10.82±4.89 (P=0.005) and 12.40±3.73% (P=0.005), respectively, after OSEM, compared with 13.11±14.93 (P=0.005) and 11.50±12.19% (P=0.005), respectively, after UHD reconstruction. CONCLUSION: As the use of CT contrast fluids results in a stronger SUV increase within the liver and mediastinal blood pool than within lymphoma tissue, this may have clinical consequences regarding visual and quantitative response assessment. Ideally, CT scans for PET attenuation correction should therefore be performed in the absence of a contrast agent.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mnm.0000000000000956

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In organs with a particularly high concentration of contrast agent (e.g., liver, kidney, or blood vessels), contrast-induced SUV deviations can be higher.

    “However, in organs with a particularly high concentration of the contrast agent (e.g., the liver, kidney, or blood vessels), these deviations can be higher [116,120,121].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [121]

    The Abstract reports that CT contrast fluids produce a stronger SUV increase in the liver and mediastinal blood pool than in lymphoma tissue. It does not establish that high contrast-agent concentration causes the larger deviations, or report this effect for the kidney. (LLM, conf=0.85)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Voltin, C.-A., Mettler, J., Boellaard, R., Kuhnert, G., Dietlein, M., Borchmann, P., Drzezga, A., & Kobe, C.
Affiliations
  • Amsterdam UMC Location Vrije Universiteit Amsterdam (NL)
  • University Hospital Cologne (DE)
Corresponding author
Voltin, Conrad-Amadeus
Venue
Nuclear Medicine Communications
Published
2019-03
Volume
40
Issue
3
Pages
249-257
ISSN
0143-3636 (ISSN-L)
OpenAlex
W2900466857
Cited by
13
References
27
Citations by year
2026: 2 · 2024: 2 · 2023: 1 · 2022: 4 · 2021: 2 · 2020: 2
FWCI
0.69
Type
journal article
Language
en
Open access
Licence
other-oa
Locations
  • Nuclear Medicine Communications (publishedVersion)
  • PubMed (publishedVersion)
  • Pure Amsterdam UMC (publishedVersion, other-oa)
  • Amsterdam UMC (VU Amsterdam) - Institutional Repository (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Pathology and Forensic Medicine › Lymphoma Diagnosis and Treatment
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
Keywords
Hodgkin's disease, attenuation correction, contrast-enhanced CT, standardized uptake value, SUVmax, SUVpeak, liver SUV, image reconstruction, OSEM, treatment response assessment, staging, image quality, image sharpness, image smoothness
MeSH terms
Adult, Aged, Contrast Media, Female, Hodgkin Disease, Humans, Image Processing, Computer-Assisted, Male, Middle Aged, Neoplasm Staging, Tomography, X-Ray Computed, Fluorodeoxyglucose F18, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›