Review: cochlear implants as a treatment of tinnitus in single-sided deafness
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE OF REVIEW: Tinnitus is a symptom that is highly associated with hearing loss. Its incidence is expected to increase due to the detrimental effects of occupational and leisure noise. Even though no standard treatment is currently available, the effect of cochlear implants on tinnitus in single-sided deafness (SSD) is under scientific attention. This review reveals an overview of all publicly available reports about cochlear implant as a treatment for tinnitus in SSD. RECENT FINDINGS: Cochlear implantation in SSD suppresses tinnitus in most of the cases. Some studies even demonstrate complete tinnitus suppression after implantation. No tinnitus worsening is reported in any of the cases. Furthermore, tinnitus does not restore during the electrical stimulation presented by the cochlear implant. The tinnitus level seems to stabilize after 3-6 months after the first fitting. SUMMARY: Although the underlying mechanism responsible for the observed tinnitus suppression is not yet clear, cochlear implantation should be considered as a treatment option for tinnitus arising from SSD. However, appropriate patient selection is essential as it is expected that it is a requirement that tinnitus arises from cochlear deafferentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Westin, V. Z., Schulin, M., Hesser, H., Karlsson, M., Noe, R. Z., Olofsson, U., Stalby, M., Wisung, G., & Andersson, G. (2011) · Behaviour Research and Therapy · doi:10.1016/j.brat.2011.08.001 · Cited by 175 · cited 2×
“Subjective tinnitus occurs in 10–15% of the general population, wherein 1–3% has severe distressing tinnitus [5].”
Background
Cited by
Mertens, G., De Bodt, M., & Van de Heyning, P. (2016) · Hearing Research · doi:10.1016/j.heares.2015.09.016 · Cited by 103
Cochlear Implants as a Treatment Option for Unilateral Hearing Loss, Severe Tinnitus and Hyperacusis
Ramos Macías, A., Falcón González, J. C., Manrique, M., Morera, C., García-Ibáñez, L., Cenjor, C., Coudert-Koall, C., & Killian, M. (2015) · Audiology and Neurotology · doi:10.1159/000380750 · Cited by 46
“…the burden of tinnitus during active CI use [Van de Heyning et al., 2008; Kleinjung et al., 2009; Vermeire and Van de Heyning, 2009; Buechner et al., 2010; Carlyon, 2010; Masgoret et al., 2010; Arndt et al., 2011; Arts et al., 2012; Firszt et al., 2012; Ramos et al., 2012; Gartrell et al., 2014].”
BackgroundA State-of-Art Review of Digital Technologies for the Next Generation of Tinnitus Therapeutics
Searchfield, G. D., Sanders, P. J., Doborjeh, Z., Doborjeh, M., Boldu, R., Sun, K., & Barde, A. (2021) · Frontiers in Digital Health · doi:10.3389/fdgth.2021.724370 · Cited by 33
Metadata
- Authors
- Arts, R. A. G. J., George, E. L. J., Stokroos, R. J., & Vermeire, K.
- Venue
- Current Opinion in Otolaryngology & Head and Neck Surgery
- Published
- 2012-10
- Volume
- 20
- Issue
- 5
- Pages
- 398-403
- ISSN
- 1068-9508 (ISSN-L)
- OpenAlex
- W2011313476
- Cited by
- 116
- References
- 1
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.