CoChat

Impact of the Warm Compress Method Conducted by Nurses Before Venipuncture on Blood Nitric Oxide Concentration

Open access
Koike, Shotaro, Norikura, Toshio, Taneichi, Akira, Yasuda, Kae, Yano, Rica · 2025 · Journal of Infusion Nursing

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Adequate venous dilation is important for successful venipuncture and infusion insertion. While the warm compress method is commonly used, its mechanism remains unclear. This study investigated the impact of the warm compress method on blood nitric oxide (NO) concentration, known for its vasodilatory properties. Using a pre-and post-intervention design, participants underwent warm compress application on the non-dominant arm. The blood NO concentration, vein cross-sectional area, and skin temperature were measured pre-and post-intervention. A warm compress was applied at 39 °C to 42 °C for 5 minutes. The skin temperature was measured pre-intervention and after applying pressure with a tourniquet; a vein cross-sectional area image was acquired using ultrasonography, and 2 mL blood was drawn to measure NO. Post-intervention, skin temperature was measured, vein cross-sectional area images were obtained, and blood was similarly collected. Data were analyzed using the Wilcoxon signed-rank sum test. Among the 19 participants (7 men and 12 women; mean age: 42.6 ± 7.5 years), significant differences were observed in skin temperature (32.05 °C versus 39.40 °C), vein cross-sectional area (11.4 mm versus 14.8 mm 2), and blood NO concentration (12.45 µmol/L and 11.18 µmol/L) pre- and post-intervention, possibly because the action of blood NO on vascular smooth muscle cells was promoted, leading to blood NO consumption.

Overview

Integrity signals

Registry

Crossref · 10.1097/nan.0000000000000579

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 23 references

Cited by

See all 3

Metadata

Authors
Koike, S., Norikura, T., Taneichi, A., Yasuda, K., & Yano, R.
Affiliations
Hokkaido University (JP)
Venue
Journal of Infusion Nursing
Published
2025-03
Volume
48
Issue
2
Pages
106-113
ISSN
  • 1533-1458 (ISSN-L)
  • 1539-0667
OpenAlex
W4408187655
Cited by
3
References
23
Citations by year
2026: 1 · 2025: 2
FWCI
3.88
Type
journal article
Language
en
Open access
Locations
  • Journal of Infusion Nursing (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
  • Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
Keywords
warm compress, venipuncture, blood nitric oxide, venous dilation, skin temperature, vasodilation, tourniquet, vascular smooth muscle
MeSH terms
Adult, Female, Humans, Male, Middle Aged, Nitric Oxide, Skin Temperature, Phlebotomy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of the Warm Compress Method Conducted by Nurses Before Venipuncture on Blood Nitric Oxide Concentration. https://app.cochat.ai/papers/10.1097/nan.0000000000000579
The paper
Koike, S., Norikura, T., Taneichi, A., Yasuda, K., & Yano, R. (2025). Impact of the Warm Compress Method Conducted by Nurses Before Venipuncture on Blood Nitric Oxide Concentration. Journal of Infusion Nursing. https://doi.org/10.1097/nan.0000000000000579

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.