CoChat

Systematic Review of Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes

Chircop, James, Sheffield, David, Kotera, Yasuhiro · 2021 · Nursing Research

The DOI matches its Crossref record; 49 of the 50 references it cites were found in a registry or an index.

Abstract

BACKGROUND: The benefit of self-monitoring of blood glucose in reducing HbA1c in non-insulin-treated participants remains unclear. HbA1c may be improved in this population with said self-monitoring. OBJECTIVE: The aim of this study was to conduct meta-analyses of glycemic control in non-insulin-treated participants with Type 2 diabetes: self-monitoring of blood glucose versus usual care, structured versus unstructured self-monitoring of blood glucose, and use of self-monitoring of blood glucose readings by clinicians to adjust (or modify) therapy versus usual care. METHODS: MEDLINE, Embase, and Cochrane Central were electronically searched to identify articles published from January 1, 2000, to June 30, 2020. Trials investigating changes in HbA1c were selected. Screening was performed independently by two investigators. Two investigators extracted HbA1c at baseline and follow-up for each trial. RESULTS: Nineteen trials involving 4,965 participants were included. Overall, self-monitoring of blood glucose reduced HbA1c. Preplanned subgroup analysis showed that using self-monitoring of blood glucose readings to adjust therapy contributed significantly to the reduction. No significant improvement in HbA1c was shown in self-monitoring of blood glucose without therapy adjustment. The same difference was observed in structured versus unstructured self-monitoring of blood glucose. DISCUSSION: HbA1c is improved with clinician therapy modification based on structured self-monitoring of blood glucose readings. Implications are for clinicians to prescribe structured self-monitoring of blood glucose to modify therapy based on the readings and not prescribe unstructured self-monitoring of blood glucose. Participants with suboptimal glycemic control may benefit most. A self-monitoring of blood glucose regimen that improves clinical and cost-effectiveness is presented. Future studies can investigate this regimen specifically.

Overview

Integrity signals

Registry

Crossref · 10.1097/nnr.0000000000000542

Cites

49 of 49 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 49 references

Cited by

See all 37

Metadata

Authors
Chircop, J., Sheffield, D., & Kotera, Y.
Affiliations
University of Derby (GB)
Venue
Nursing Research
Published
2021-07-21
Volume
70
Issue
6
Pages
487-497
ISSN
  • 0029-6562 (ISSN-L)
  • 1538-9847
OpenAlex
W3186342387
Cited by
34
References
50
Citations by year
2026: 5 · 2025: 11 · 2024: 5 · 2023: 9 · 2022: 4
FWCI
0.69
Type
journal article
Language
en
Open access
closed
Locations
  • Nursing Research (publishedVersion)
  • PubMed (publishedVersion)
  • University of Derby Online Research Archive. (University of Derby) (submittedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
Keywords
self-monitoring of blood glucose, type 2 diabetes, glycemic control, HbA1c, non-insulin-treated patients, usual care, cost-effectiveness
MeSH terms
Adult, Aged, Aged, 80 and over, Blood Glucose, Diabetes Mellitus, Type 2, Female, Glycated Hemoglobin, Humans, Male, Middle Aged, Blood Glucose Self-Monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systematic Review of Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes. https://app.cochat.ai/papers/10.1097/nnr.0000000000000542
The paper
Chircop, J., Sheffield, D., & Kotera, Y. (2021). Systematic Review of Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes. Nursing Research. https://doi.org/10.1097/nnr.0000000000000542

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.