Cited by 29Ophthalmology and Visual Impairment StudiesVisual perception and processing mechanismsAdvanced optical system design

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

Visual Performance with Lenses Correcting Peripheral Refractive Errors

Open access
Atchison, David A., Mathur, Ankit, Varnas, Saulius R.·2013·Optometry and Vision Science

Abstract

Purpose: To design and manufacture lenses to correct peripheral refraction along the horizontal meridian and to determine whether these resulted in noticeable improvements in visual performance. Methods: Subjective refraction of a low myope was determined on the basis of best peripheral detection acuity along the horizontal visual field out to ±30° for both horizontal and vertical gratings. Subjective refraction was compared to objective refractions using a COAS‐HD aberrometer. Special lenses were made to correct peripheral refraction, based on designs optimized with and without smoothing across a 3‐mm diameter square aperture. Grating detection was retested with these lenses. Contrast thresholds of 1.25‐min arc spots were determined across the field for the conditions of best correction, on‐axis correction, and the special lenses. Results: The participant had high relative peripheral hyperopia, particularly in the temporal visual field (maximum, 2.9 D). There were differences >0.5 D between subjective and objective refractions at a few field angles. On‐axis correction reduced peripheral detection acuity and increased peripheral contrast threshold in the peripheral visual field, relative to the best correction, by up to 0.4 and 0.5 log units, respectively. The special lenses restored most of the peripheral vision, although not all at angles to ±10°, and with the lens optimized with aperture smoothing possibly giving better vision than the lens optimized without aperture smoothing at some angles. Conclusions: It is possible to design and manufacture lenses to give near‐optimum peripheral visual performance to at least ±30° along one visual field meridian. The benefit of such lenses is likely to be manifest only if a subject has a considerable relative peripheral refraction, for example, of the order of 2 D.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/opx.0000000000000033

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • FFLs show consistently lower peripheral astigmatism and mean power error than ASLs, especially at greater than 20 to 30 degrees eccentricity and high plus or minus powers.

    “FFLs demonstrate consistently lower peripheral astigmatism and mean power error”

    From Freeform vs. Aspheric Spectacle Lenses: A Comprehensive Review of Optical Performance, Clinical Outcomes, and Patient Considerations (2026) · cites this paper as [34]

    The Lenses section compares two specially designed lenses, one optimized with aperture smoothing and one without. The Discussion reports peripheral visual performance for a participant, but our copy does not compare FFLs with ASLs or report consistently lower peripheral astigmatism and mean power error for FFLs, including at the stated eccentricities and powers. (LLM, conf=0.75)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 4

  1. Rovamo J, 1982, Resolution of gratings oriented along and across meridians in peripheral vision, Invest Ophthalmol Vis Sci, 23, 666
  2. Wang YZ, 1997, Effects of refractive error on detection acuity and resolution acuity in peripheral vision, Invest Ophthalmol Vis Sci, 38, 2134
  3. Lewis PR, 2012, The effect of refractive‐correction on peripheral low‐contrast resolution acuity, Invest Ophthalmol Vis Sci, 53
  4. VarnasSR.Ophthalmic lens element. WO 2009/052570 A1. April 30 2009. · DOI

Metadata

Authors
Atchison, D. A., Mathur, A., & Varnas, S. R.
Affiliations
Queensland University of Technology (AU)
Corresponding author
Atchison, David A.
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2013-11
Volume
90
Issue
11
Pages
1304-1311
ISSN
  • 1040-5488 (ISSN-L)
  • 1538-9235
OpenAlex
W152742661
Cited by
29
References
36
Citations by year
2026: 2 · 2024: 4 · 2022: 1 · 2021: 5 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 3 · 2016: 6 · 2015: 1 · 2014: 2 · 2013: 1
FWCI
2.43
Type
journal article
Language
en
Open access
Locations
  • Optometry and Vision Science (publishedVersion)
  • PubMed (publishedVersion)
  • QUT ePrints (Queensland University of Technology) (submittedVersion)
  • Faculty of Health; Institute of Health and Biomedical Innovation
Topics
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced optical system design
Keywords
peripheral refraction, visual field, contrast threshold, low myopia, subjective refraction, objective refraction, horizontal meridian
MeSH terms
Eyeglasses, Humans, Male, Middle Aged, Myopia, Prosthesis Design, Refraction, Ocular, Vision, Ocular, Visual Acuity, Contrast Sensitivity, Aberrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review