The DOI matches its Crossref record.
The Effects of Age, Refractive Status, and Luminance on Pupil Size
Open accessAbstract
Purpose: Pupil size is critical for optimal performance of presbyopic contact lenses. Although the effect of luminance is well known, little information is available regarding other contributing factors such as aging and refractive status. Methods: The cohort population comprised 304 patients (127 male, 177 female) aged 18 to 78 years. Pupils were photographed at three controlled luminance levels 250, 50, and 2.5 cd/m 2 using an infra‐red macro video camera. Measurements of pupil diameter were conducted after transforming pixel values to linear values in millimeters. Results: Luminance was the most influential factor with pupil diameter increasing with decreased luminance (p < 0.001, all comparisons). Age was also found to be a significant factor with a smaller diameter in the older groups, but overall the difference was only significant between the pre‐presbyopes and the established presbyopes (p = 0.017). Pupil diameter decreased significantly with increasing age, the effect being most marked at low luminance (<0.001). The smallest pupil diameters were measured for hyperopes and the largest for myopes and although refractive error was not a significant factor alone, there was a significant interaction between luminance and refractive error with the greatest differences in pupil diameter between myopes and emmetropes at low luminance (p < 0.001). Pupil diameter changes modeled by multilinear regression (p < 0.001) identified age, luminance, best sphere refraction, and refractive error as significant factors accounting for just over 70% of the average variation in pupil diameter. Conclusions: Both age and refractive status were found to affect pupil size with larger pupils measured for younger patients and myopes. Designs for multifocal contact lens corrections should take both age and refractive status into consideration; a faster progression from distance to near corrections across the optical zone of the lens is expected to be required for established presbyopes and hyperopes than it is for early presbyopes, myopes, and emmetropes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Presbyopia: Effectiveness of correction strategies
Wolffsohn, J. S., & Davies, L. N. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.09.004 · Cited by 324
Shou, B. L., Venkatesh, K., Chen, C., Ghidey, R., Lee, J. H., Wang, J., Channa, R., Wolf, R. M., Abramoff, M. D., & Liu, T. Y. A. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231201654 · Cited by 5
Metadata
- Authors
- Guillon, M., Dumbleton, K., Theodoratos, P., Gobbe, M., Wooley, C. B., & Moody, K.
- Venue
- Optometry and Vision Science
- Publisher
- Wiley
- Published
- 2016-09
- Volume
- 93
- Issue
- 9
- Pages
- 1093-1100
- ISSN
- 1040-5488 (ISSN-L)
- 1538-9235
- OpenAlex
- W2404073272
- Cited by
- 184
- References
- 0
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effects of Age, Refractive Status, and Luminance on Pupil Size. https://app.cochat.ai/papers/10.1097/opx.0000000000000893
- The paper
- Guillon, M., Dumbleton, K., Theodoratos, P., Gobbe, M., Wooley, C. B., & Moody, K. (2016). The Effects of Age, Refractive Status, and Luminance on Pupil Size. Optometry and Vision Science. https://doi.org/10.1097/opx.0000000000000893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.