CoChat

Effects of light scatter and blur on low-contrast vision and disk halo size

Puell, María Cinta, Palomo‐Álvarez, Catalina · 2017 · Optometry and Vision Science

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Abstract

Purpose: To investigate the individual effects of forward light scatter (FLS) and refractive blur on low‐contrast vision and the size of the disk halo produced in response to an external glare source. Methods: Monocular disk halo radius, high‐ and low‐contrast distance visual acuity (HCVA, LCVA), and contrast sensitivity (CS) were determined in 25 eyes of 25 healthy subjects under normal, FLS, and blur conditions. FLS was induced using the filter Black ProMist 2 to simulate an early cataract. Blur was induced using a +1.00 diopter lens to simulate an uncorrected refractive error. Results: Similar significant mean increases in halo radius were observed for the FLS (0.32 ± 0.10 log arc min; P <. 0001) and refractive blur (0.40 ± 0.18 log arc min; P <. 0001). Under induced blur, 3 lines of HCVA (0.32 ± 0.15 logMAR; P <. 0001) and 4 lines of LCVA (0.39 ± 0.16 logMAR; P <. 0001) were lost. FLS had a minimal (but significant) effect on HCVA, but worsened mean LCVA by more than 1 line (0.13 ± 0.10 logMAR; P <. 0001). Similar significant mean CS reductions of 0.17 ± 0.12 ( P <. 0001) and 0.14 ± 0.12 log units ( P <. 0001) were produced in response to FLS and refractive blur, respectively (approximately 1 triplet). Conclusions: Forward light scatter and refractive blur contributed to an increased size of the disk halo produced by a glare source in similar proportion. Although defocus blur has a substantial effect on LCVA, a loss of more than 1 line of LCVA after best refractive correction would be indicative of FLS.

Overview

Integrity signals

Registry

Crossref · 10.1097/opx.0000000000001061

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 40 references

Cited by

See all 12

Metadata

Authors
Puell, M. C., & Palomo‐Álvarez, C.
Affiliations
  • Applied Vision Research Group Faculty of Optics and Optometry Universidad Complutense de Madrid Madrid Spain
  • Universidad Complutense de Madrid (ES)
Corresponding author
Palomo‐Álvarez, Catalina
Venue
Optometry and Vision Science
Publisher
Wiley
Published
2017-04
Volume
94
Issue
4
Pages
505-510
ISSN
  • 1040-5488 (ISSN-L)
  • 1538-9235
OpenAlex
W2589199422
Cited by
9
References
39
Citations by year
2026: 2 · 2024: 2 · 2022: 1 · 2021: 1 · 2020: 3
FWCI
0.65
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • Optometry and Vision Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Impairment Studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Visual perception and processing mechanisms
  • Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
Keywords
forward light scatter, low-contrast vision, glare, contrast sensitivity, visual acuity, uncorrected refractive error, defocus blur
MeSH terms
Adult, Female, Humans, Light, Male, Refractive Errors, Scattering, Radiation, Vision Tests, Visual Acuity, Contrast Sensitivity, Vision, Low, Glare, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of light scatter and blur on low-contrast vision and disk halo size. https://app.cochat.ai/papers/10.1097/opx.0000000000001061
The paper
Puell, M. C., & Palomo‐Álvarez, C. (2017). Effects of light scatter and blur on low-contrast vision and disk halo size. Optometry and Vision Science. https://doi.org/10.1097/opx.0000000000001061

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.