Compensation Comparison Method for Assessment of Retinal Straylight
Open accessAbstract
PURPOSE: Presently, no instrument or method exists that is generally accepted for routine clinical assessment of (functional) retinal straylight. Yet retinal straylight is the cause of major patient complaints, such as hindrance from glare and loss of contrast. It results from disturbances in the optical media that increase light-scattering over angles of 1 degrees to 90 degrees . Its assessment would help to decide whether to perform surgery for (early) cataract and would help in the evaluation of corneal or vitreal turbidity. METHODS: The psychophysical technique of the "direct compensation" method was adapted to make it suitable for routine clinical assessment. In the new approach, called "compensation comparison, " the central test field is subdivided into two half fields: one with and one without counterphase compensation light. The subject's task is a forced-choice comparison between the two half fields, to decide which half flickers more strongly. A theoretical form for the respective psychometric function was defined and experimentally verified in a laboratory experiment involving seven subjects, with and without artificially increased light scattering. The method was applied in a separate multicenter study. Its reliability was additionally tested with a commercial implement (C-Quant; Oculus Optikgeräte, Wetzlar-Dutenhofen, Germany). RESULTS: A repeated-measures SD of 0.07 log units was achieved, to be compared with differences in the young normal population of 0.4 log units and an increase with healthy aging by 0.5 log units at 80 years and by 1.0 or more log units with (early) cataract or corneal disturbances. Reliability was further found to be high when using the commercial version of the CONCLUSIONS: The compensation comparison method for measuring retinal straylight is suited for clinical use to diagnose patients with complaints caused by large angle light scattering in the eye such as early cataract.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive psychophysical procedures
Treutwein, B. (1995) · Vision Research · doi:10.1016/0042-6989(95)00016-s · Cited by 648
Turner, R. P., Jared, D. A., Johnson, K. M., Crossland, W. A., Birch, M. J. H., Vass, D., & Underwood, I. (1990) · Cited by 580
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90229-o · Cited by 276
The Fundamentals of Glare and Visibility
Holladay, L. L. (1926) · Journal of the Optical Society of America · doi:10.1364/josa.12.000271 · Cited by 270
Efficient estimation of sensory thresholds
Harvey, L. O. (1986) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03201438 · Cited by 258
Assessing the reliability, discriminative ability, and validity of disability glare tests.
Elliott, D. B., & Bullimore, M. A. (1993) · PubMed · Cited by 246
IJspeert, J. K., de Waard, P. W. T., van den Berg, T. J. T. P., & de Jong, P. T. V. M. (1990) · Vision Research · doi:10.1016/0042-6989(90)90096-4 · Cited by 239
Self-citationDisability Glare A State of The Art Report
Vos, J. J. (1984) · Medical Entomology and Zoology · Cited by 214
Importance of pathological intraocular light scatter for visual disability
Van Den Berg, T. J. T. P. (1986) · Documenta Ophthalmologica · doi:10.1007/bf00142360 · Cited by 196
Self-citationIntraocular light scattering in age-related cataracts.
de Waard, P. W., Ijspeert, J. K., Berg, T., & de Jong, P. T. (1992) · PubMed · Cited by 180
Cited by
Effects of light scatter and blur on low-contrast vision and disk halo size
Puell, M. C., & Palomo‐Álvarez, C. (2017) · Optometry and Vision Science · doi:10.1097/opx.0000000000001061 · Cited by 9
Metadata
- Authors
- Franssen, L., Coppens, J. E., & van den Berg, T. J. T. P.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2006-02-01
- Volume
- 47
- Issue
- 2
- Pages
- 768
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2144755241
- Cited by
- 262
- References
- 18
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compensation Comparison Method for Assessment of Retinal Straylight. https://app.cochat.ai/papers/10.1167/iovs.05-0690
- The paper
- Franssen, L., Coppens, J. E., & van den Berg, T. J. T. P. (2006). Compensation Comparison Method for Assessment of Retinal Straylight. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.05-0690
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.